WarmYourFloor SunTouch P-3285 Instructions

Dualtemp digital thermostat

Advertisement

Quick Links

SunTouch P-3285 DualTemp Digital Outdoor Instructions
24v for use with CP ContactorPro Panels (CP-50/100/200)
To enter the parameter menu, press and hold the OK button for 5 seconds.
Use the +/- keys to select the installation parameter to be adjusted.
Press OK to toggle the parameter setting or to edit its value. When the value begins to blink, use the
+/- keys to adjust its value. Press OK to select the adjusted value.
Toggle to "End" and press OK to exit the installation parameter menu.
(Only Bold apply to Outdoor Patio Heating)
Parameters
• J0: °C/°F Temperature display section.
J1: Hot
Cy: Proportional Integral regulation time cycle, value in minutes (default: 15 minute cycle).
bp: Proportional Integral regulation band amplitude value in degrees °C/°F (default: 2.0°C/3.6°F).
J4
: NO/
NC: If using an isolation relay and/or a relay box.
NO: if connecting to a Watts Zone Valve control.
J5: Select PMP (Pump Maintenance Program) to perform a 1 minute exercise every day.
J6:
Air: Air (room) setpoint. Displays air temperature with floor low (FL) and high (FH) limits.
Flr: Floor (external sensor) setpoint. Displays floor temperature
without floor low/high limits. Air temperature is not a control
boundary.
Air temp is not used because the T-stat is mounted INSIDE and the
area to be monitored is OUTSIDE and monitored with Floor Sensor
Only
J7: rEG (proportional Integral) or HYs (0.3°C Hysteresis) regulation type selection.
Cp: Proportional Integral regulation temperature compensation value in °C/°F
(default: 2.0°C/3.6°F).
Ao: Air Sensor offset adjustment (default: no offset), display measure air sensor value.
Fo: Floor sensor offset adjustment (default: no offset), display measure floor
sensor value.
FL: Floor temperature LOW limitation (default: 5°C/41°F), effective only if floor
sensor present and set J6 to Air.
FH: Floor temperature HIGH limitation (default: 28°C/82°F), effective only if floor
sensor present and set J6 to Air.
CLr: Press OK to reset to factory defaults.
• End: Press OK to exit installation parameters.
/Cold regulation mode. Select Hot for Heating, Cold for cooling.
NC
Normally Open or Normally Close actuator selection.
23055 Alcalde Drive, Laguna Hills, CA 92653
Toll Free 866 – 558 – 3369 ● Fax 866 – 558 – 2010
CustomerCare@warmyourfloor.com
www.WarmYourFloor.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the SunTouch P-3285 and is the answer not in the manual?

Questions and answers

Summary of Contents for WarmYourFloor SunTouch P-3285

  • Page 1 Toll Free 866 – 558 – 3369 ● Fax 866 – 558 – 2010 www.WarmYourFloor.com CustomerCare@warmyourfloor.com SunTouch P-3285 DualTemp Digital Outdoor Instructions 24v for use with CP ContactorPro Panels (CP-50/100/200) To enter the parameter menu, press and hold the OK button for 5 seconds.
  • Page 2 07-3-857-40-02 For Residential and Commercial Applications Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location ––––––––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––– DualTemp Digital Thermostat Dimensions: 3-3/8" x 3-3/8" The Watts Radiant DualTemp thermostat has the ability to sense the temperature of the air, fl...
  • Page 3 PARAMETER MENU INSTALLATION PARAMETERS To enter the parameter menu, press and hold the OK button °C/°F Temperature display section. for 5 seconds. Hot/Cold regulation mode. Select Hot for Heating, Cold for cooling. Cy: Proportional Integral regulation time cycle, value in minutes Use the +/- keys to select the installation parameter to be adjusted.