Milan Blagojevic Royal 900 Owner's Manual

Solid fuel room heater

Advertisement

Quick Links

Manufactured by:
Milan Blagojevic AD
Djure Strugara 20
11300 Smederevo
Serbia
www.mbs.rs
Listed: UL 1482, ULC-S627
PLEASE READ ALL INSTRUCTIONS BEFORE YOU INSTALL YOUR NEW STOVE.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
SAFETY NOTICE: FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE
OFFICIAL ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIRE-
MENTS FOR YOUR AREA. PLEASE CHECK WITH YOUR INSURANCE BEFORE
USING IN YOUR HOME. USE PROFESSIONAL INSTALLER.
C A U T I O N
Hot while in operation– do not touch
Contact may cause skin burns
Keep children and clothing away
Keep furnishing and other combustible materials
a considerable distance away from stove.
Do not overfire. If stove or chimney connector glows, you are overfiring
DO NOT INSTALL IN MOBILE HOME OR TRAILER
Owners Manual
for
Royal 900
Royal 720
Revised November 2011
BODILY INJURY, OR EVEN DEATH.
Imported by:
Sopka Inc
4181 Plymouth Road
Cleveland, OH 44109
USA
www.sopkainc.com
Solid Fuel Room Heater
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Royal 900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Milan Blagojevic Royal 900

  • Page 1 Owners Manual Royal 900 Royal 720 Revised November 2011 Manufactured by: Imported by: Milan Blagojevic AD Sopka Inc Djure Strugara 20 4181 Plymouth Road 11300 Smederevo Cleveland, OH 44109 Serbia www.mbs.rs www.sopkainc.com Listed: UL 1482, ULC-S627 Solid Fuel Room Heater PLEASE READ ALL INSTRUCTIONS BEFORE YOU INSTALL YOUR NEW STOVE.
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS Read all instructions carefully. 1. The installation of this stove must comply with your local building codes. Please observe the clearance to combustible. Stove must be 18”(46 cm) from any combustible material, wall, wood, furniture, paper, etc. Note: Drywall faced with bricks or stone should be con- sider a combustible surface.
  • Page 3: Installation Instruction

    8”(20 cm) to the sides, and MUST extend under the stove pipe. (Check local building codes and fire protection ordinances.) Floor protector minimum size; Royal 900 is 51.5”W by 49.5”D (1308 mm X 1257 mm ); Royal 720 is 44.5” W by 49.5”D ( 1130 mm X 1257 mm ).
  • Page 4 Chimney connector systems and clearances Chimney connector shall not pass through attic or roof space, closet or similar concealed space, or a floor, or ceiling. When passage through a wall, or partition of combustible is desired, the installation shall con- form to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment:...
  • Page 7: Minimum Clearances To Combustible Surfaces

    MINIMUM CLEARANCES TO NOTE: DRYWALL FACED WITH BRICK OR COMBUSTIBLE SURFACES STONE SHOULD BE CONSIDER A COMBUS- TIBLE SURFACE. Unit to Sidewall - - - - - - - - - - - -18” (46 cm) Unit to Backwall - - - - - - - - - - - -18” (46 cm) CAUTION: KEEP FURNISHING AND OTHER COMBUSTIBLE MATERIALS AWAY FROM Unit Corner to wall - - - - - - - - - 18”( 46 cm)
  • Page 8: Operating Safety Precautions

    CAUTION: HOT WHILE IN OPERATION. KEEP CHILDREN, ANIMALS, CLOTH- ING AND FURNITURE AWAY FROM THE STOVE. DO NOT TOUCH HOT STOVE. CONTACT MAY CAUSE SKIN BURNS. TRAIN CHILDREN TO STAY A SAFE DIS- TANCE FROM THE UNIT. CHILDREN SHOULD BE ALL THE TIME CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE STOVE.
  • Page 9 If those materials or UL 1618 listed floor protector are not available, materials with R- value of at least 0.8 may be substituted. Floor protector minimum size; Royal 900 is 51.5” W by 49.5” D (1308mm X 1257mm); Royal 720 is 44.5” W by 49.5” D ( 1130 mm X 1257 mm).
  • Page 10 Oven glass: Replace oven glass only with original “Fully tempered soda-lime” glass available from manufacturer or authorized dealer.
  • Page 12 IF THE CHIMNEY CONNECTOR GLOWS RED, IMMEDIATELY CALL THE FIRE DEPARTMENT...
  • Page 17: Floor Protector

    BACK WALL CEILING 18” 46 cm 18” 46 cm 48” 122 cm 18” 46 cm 18” 46 cm SINGLE WALL PIPE-MINIMUM CLEARANCES FOR USA/CANADA Some example of clearance reduction; - Using heat shields on back and sidewalls allowing at least 1” of space away from the walls for ventilation.
  • Page 18 Installation must be done in accordance with installation instructions included with product and all local and national building and fire codes. Milan Blagojevic AD will not be liable for incidental and consequential damage of any nature. This warranty gives the purchaser specific legal rights which may vary from state to state.
  • Page 19 Safety label...