SPECIFICATION SUMMARY  
 
MATERIALS 
‐ Inner shell ‐ Duplex Stainless Steel 
‐ Coil ‐ Stainless Steel AISI 316L 
‐ Bosses ‐ Stainless Steel 
‐ Every cylinder is water tested to a pressure of 10bar. 
 
INSULATION 
‐ Fire retardant polyurethane foam, nominal thickness 45‐50mm. 
‐ The foam is CFC‐Free and HCFC‐Free. 
‐ The foam has an Ozone Depletion Potential of Zero and a Global Warming 
 
CASEWORK 
‐ Electrostatically painted steel  
 
ANODE 
‐ None fitted/none required  
 
EXPANSION VESSEL  
‐  
CONTROL SETTINGS  
‐ Pressure Reducing Valve ‐ 3 Bar  
‐ Expansion Relief Valve ‐ 6 Bar  
‐ Pressure and Temperature Relief Valve ‐ 7 Bar/90°C  
‐ High Limit Thermostat in Dual Thermostat 
‐ High Limit Thermostat in Immersion Heater 
IMMERSION HEATER  
‐ 1¾" BSP Parallel Threaded Head  
‐ Long Life Incoloy Sheathed Low Noise Element 16" 
‐ Long Long Life Incoloy Sheathed Thermostat Pocket  
‐ Brazed Construction  
‐ Combined Thermostat and Safety Cutout  
‐ Element Rating 3kW at 240V A/C  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 