Summary of Contents for United States Stove Company 1821
Page 1
OWNERS MANUAL SMALL PLATE HEATER MODELS: 1821, 1821B, 1821A, 1821Q SAFETY NOTICE: CAUTION! If this heater is not properly installed, a house fire may Read All Instructions Carefully result. For your safety, follow the installation instruc- Before Starting The Installation tions.
Page 2
CONGRATULATIONS! You've purchased a heater from North America's oldest manufacturer of wood burning products. By heating with wood you're helping to CONSERVE ENERGY! Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one tree each year.
SAFETY RULES SAFETY NOTICE: If this heater is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Read these rules and the instructions carefully. Check with local codes.
Page 4
LOCATING THE ROOM HEATER AS A LOCATION IS SELECTED, KEEP THE FOLLOWING IN MIND: 1. Keep the chimney connection as short as possible. Have the floor protector extended 14-1/2" in front of the The heater must have its own chimney flue. Do not hearth extension, 1-3/4"...
Page 5
MOUNTING CAST-IRON FLUE COLLAR This heater comes equipped with a cast-iron flue collar with holes to mount the solid damper as shown below. Flue Collar - 24561 Solid Damper - D6 5/16-18 x 1-1/2" Bolts (3 req.) - 83432 Weld Tab (3 req.) - 83431 Gasket - 88042 Holes in Flue collar where bolts attach...
CHIMNEY CONNECTION Two basic types of chimneys are approved for use with solid fuel. Factory-built and ma- sonry. Factory-built chimney must comply with UL 103HT standard. Do not expect your stove or furnace to create draft. Draft is not a function of the appliance. Draft is purely a function of the chimney.
Page 8
VENTING INTO A FIREPLACE Many people may wish to convert an existing fireplace to When considering a masonry chimney, round tiles are heater use. Usually, safe connection of stovepipe to a preferable to square or rectangular, as round tiles have much masonry chimney requires more effort than connection to a better airflow characteristics and are far easier to clean.
"FIREPLACE" INSTALLATION (CONT'D) FIREPLACE INSTALLATION Do not use the Type B installation (not illustrated in this manual), that is, venting up through the Connection of the stovepipe directly into the fireplace opening, regardless of whether the fire- existing masonry chimney over the fireplace open- place opening is closed.
Page 10
RULES FOR CONNECTOR PIPE INSTALLATION Crimped end of the pipe must be installed toward the heater. The pipe should slide inside the flue collar. The pipe should be firmly attached to the flue collar with 3 screws and sealed with furnace cement.
OPERATING INSTRUCTIONS WARNING! NEVER STORE FLAMMABLE LIQUIDS, Wood Fuel ESPECIALLY GASOLINE. IN THE VICINITY OF THE HEATER. Use Hardwood that has been split and air-dried to obtain maximum burning efficiency. CAUTION! OVERFIRING THE APPLIANCE MAY Lighting Instructions CAUSE A HOUSE FIRE. IF A UNIT OR CHIMNEY CONNECTOR GLOWS, YOU Open door and place paper and kindling in the ARE OVERFIRING.
GLASS REPLACEMENT INSTRUCTIONS FOR MODEL 1821 Be sure heater has cooled before begin- Use part no. 89155 only, to replace broken ning. glass. (8" x 10' x 5mm Robax #85713 Remove 3, 10-24 x 1/4 screws (13) and Jena Glasswerk Schott & Gen., INC. New glass retainer (12) with screw driver.
Page 13
PARTS LIST FOR MODEL 1821 PART # DESCRIPTION QTY. 22292 FEED DOOR (FEED DOOR ASSY. #68687) 89155 GLASS 89577 FEED DOOR HANDLE 23445 DOOR LATCH 21467 LATCH SPACER 83461 HANDLE WASHER 83274 3/8-16 LOCK NUT 83227 1/4-20 X 1 MACHINE SCREW...
Page 14
REPAIR PARTS DESCRIPTION PART # QTY. Blower Motor 80442 Blower Housing Front 25090B Blower Housing Back 25089B Power Supply Cord 80232 Rheostat w/Nut and Knob 80090 Strain Relief Bushing 80109 #10AB x 3/8 Hex Zinc Screw 83222 #12 x 3/4 Teks Screw C23799 BRICK PLACEMENT - (TOP INSIDE VIEW OF FIREBOX) 1.
Page 15
Repair Parts For 1821Q Feed Door Assembly DESCRIPTION PART # QTY. Feed Door Assembly 68988 (Includes all of below) Feed Door 24267 Door Handle 89577 Brass Spring Handle 89574 Air Deflector 24180 10-24 Machine Screw 83362 Flat Washer (3/8 I.D. 7/8 O.D.) 83045A Door Latch 23445...
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST: 1. The PART NUMBER 2. The PART DESCRIPTION 3. The MODEL NUMBER: 1821 1821Q 4. The SERIAL NUMBER: ____________________ UNITED STATES STOVE COMPANY 227 Industrial Park Road P.O.