Hasco Z 12402 Series Operating Instructions Manual

Process monitor

Advertisement

Quick Links

Operating Instructions
Z 12402 /. . .
Process monitor
GB 12/13
HK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Z 12402 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hasco Z 12402 Series

  • Page 1 Operating Instructions Z 12402 /. . . Process monitor GB 12/13...
  • Page 2: Table Of Contents

    Content General Safety attention Start 1.2.1 Online – Offline Operation elements 1.3.1 Operation of the controller Description of features Operation of the connected MCS-controllers Password Snapper Headline Indication 2.4.1 Total 2.4.2 Detail 2.4.3 Groups assortment Tool Trends 2.6.1 Filter 2.6.2 History / Live 2.6.3 Power and energy...
  • Page 3 Tool Setup End of setup View New Touch-section New value: actual, setpoint, output rate or current 4.4.1 Indicate title 4.4.2 Move 4.4.3 Change 4.4.4 Copy size 4.4.5 Alignment Delete Technical data User level 5.1.1 Service 5.1.2 Configuration 5.1.3 Tuning 5.1.4 Operation 5.1.5 Indication...
  • Page 4: General

    General Z 12402 The monitor is designed for comfortable operator interface with data storage and diagnosis. Safety attention Z 12402 The monitor will be powered by the low voltage net. The local and general instruc- tions have to be observed for the installation and operation. The supply voltage and frequency must correspond to the data on the label! The maker and seller of the units are not responsible for direct or indirect damages due to incorrect operation.
  • Page 5: Password

    Operation of the connected Z 1240 / 1246 The operation of the controllers happens by the different zones. These may be collected in groups or operated separately. The control units itself will not appear in the structure of Z 12402. Different functions are available at the right hand side or directly by additional menus.
  • Page 6: Snapper

    Snapper This button takes screenshots / hardcopies. Stores the actual picture in an external memory. Prints the actual picture by a connected printer. Escape Headline The headline represents the name of the actual tool and recipes with current relevance. Indication The control zones may be indicated by Total, Detail or the single zone.
  • Page 7: Detail

    2.4.2 Detail Zones Zones Tool-Image Total Zones Trends Detailed Alarms Reports Total Input Assorted Detailed Groups Assorted Diagnosis Help Commissioning Screenshot Report Status Level The shifter on the left hand side chooses the selection. The touch on a zone opens the screen of a single zone. The touch on the colour of a group opens the screen of the zones of this group.
  • Page 8: Tool

    Tool Main Setup picture Zones Tool-Image Trends Alarms Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level The assembly of a tool will be described in the chapter Tool Setup. The functions of the tool illustration depend on the referring design. Trends Power Curves...
  • Page 9: Filter

    2.6.1 Filter The filter enables a collection of zones for the trend-curves. Different groups, an individual selection of zones and zones without group are available. Actual values, setpoints and output rates are available for this collection by a touch. The colours refer to the legend in the upper section. 2.6.2 History / Live The illustration of actual or historical data may be selected by this screen or in the headline.
  • Page 10: Power And Energy

    Power and energy The setting History enables a selection of the 2 diagrams with temperatures and output rates or the effective power. The power diagram presents the zones, which had been selected before by the filter. A red line marks the arithmetic mean value. Power Curves bars...
  • Page 11: Alarms And Reports

    Alarms and reports 2.7.1 System reports Zones System Tool-Image Messages Trends Fault Alarms Statistic Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level The confirmation refers only to the actual selection. The padlock disables the automatic scrolling of the list. All activities and alarms are listed here referring to date and time.
  • Page 12: Fault Statistics

    2.7.2 Fault statistics Zones System Tool-Image Messages Trends Fault Alarms Statistics Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level The fault statistics indicate the longest failure times of 10 zones by bar graph. Settings for the zones Zones Input Tool-Image Zone Trends...
  • Page 13: Zone-Parameters

    2.8.2 Zone-parameters Zones Input Tool-Image Zone Trends Parameters Alarms Reports Global Input Parameters Groups Default Diagnosis Parameters Commissioning Screenshot Report Status Level The individual parameters of the selected zones may be set according to the manual of con- trollers. 2.8.3 Global Parameters Zones Input Tool-Image...
  • Page 14: Groups

    Zones Input Tool-Image Zone Trends parameters Alarms Reports Global Input parameters Groups Recipes Diagnosis Commissioning Screenshot Report Status Level The loss of relevance in case of changed settings will be indicated in the headline. Groups Zones Tool-Image Trends Alarms Reports Input Groups Selection...
  • Page 15: Rename Zone

    2.9.1 Rename zone The zones may get typical names that do not correspond to the numbers of Z 1240 / 1246. The referring button opens a menu to rename a marked zone. A number within the name will be set for the 1st zone of this selection and increased for all the follow- ing.
  • Page 16: Commissioning

    Commissioning Mount the monitor The monitor has to be fastened to the VESA flange of the stand. The stand has to be fastened with a screw M8 on top of the controller cabinet. Connection There is a separate AC/DC adapter for the pow- er supply.
  • Page 17: Clock

    3.3.1 Clock A double click to the real time opens the setting of the time. Operator level Service is required for the referring Windows® menu. 3.3.2 Program settings – Z 12402 Zones Tool-Image Trends Alarms Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level...
  • Page 18: Rs485 - Interface Input

    3.3.3 RS485 – Interface input Zones Tool-Image Trends Alarms Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level The transmission rate may differ from the default settings • RS485 driver • 9600Baud, if it is required by the installation. With the MCS series 2008 the baud rate will be set by itself to the optimal value. 3.3.4 RS485 –...
  • Page 19: Tool-Selection

    3.3.7 Tool-Selection Zones Tool-Image Trends Alarms Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level • A new tool has to be opened and activated for each application, that shall be stored with its settings. This includes a copy, that was renamed. •...
  • Page 20: Groups-Settings

    3.3.8 Groups-Settings Zones Tool-Image Trends Alarms Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level This menu enables to select the quantity, the names and the colour of groups. For selectable groups the change of setpoints is lockable. Z 1240 / 46 series For Boost and Standby the required settings will appear in this table.
  • Page 21: Printer-Settings

    3.3.11 Printer-Settings Zones Tool-Image Trends Alarms Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level The selection of a printer enables to enter the required settings. The direction of the print changes with a touch on the empty section. The desired printer and settings may be selected from the different installed types. The set- tings for the frame will open after touch.
  • Page 22: Diagram-Settings

    3.3.13 Diagram-Settings The representation of curves and bars may be set individually. Zones Tool-Image Trends Alarms Reports Input Groups Diagnosis Commissioning Screenshot Report Status Level • An alignment of the curves depends on the zoom-factor. • The rate of alignment can smooth the curves. •...
  • Page 23: Tool Setup

    Tool Setup The illustration of the tool has to be prepared in the setup. Zones Title of Tool-Image zones Trends Move zone Alarms section Reports Change Input size Groups Diagnosis Delete Commissioning Screenshot Report Status Level The following example shows the structure of the tool operation. The survey and zoom- effects may be created this way.
  • Page 24: End Of Setup

    New components for the tool representation have to be selected from here to be pulled in the desired position. End of setup This button ends the setup and offers the storage. View This button opens the selection of loaded pictures. The selected picture may be arranged.
  • Page 25: Alignment

    4.4.5 Alignment An assistance line may be pulled out of the top and the left side of the frame. It helps to align the measured val- ue sections. When the top or left edge of a section will be moved or touched close to this line, it will align itself. Delete To delete a section, it has to be shifted to the waste-basket and confirmed after.
  • Page 26: Technical Data

    Technical data Monitor: Control voltage: Via AC/DC adapter 100..240VAC/1,5A / 50/60Hz 12VDC Power consumption: 80 W Interface Serial at COM3 RS485 USB 2.0 4-fold Protocol FE3-Bus Version 3.03 Ambient conditions Operation temperature 5..45°C / 40..122°F Storage temperature 0..60°C / 32..°F Humidity <...
  • Page 27: Tuning

    5.1.5 Indication Z 12402 is locked. No settings are possible without password. © by HASCO · Postfach 1720 · D-58467 Lüdenscheid · Tel. +49 (0) 2351 957-0 · Fax +49 (0) 2351 957-237 · www.hasco.com · info@hasco.com 12 13 1 i...