Maintenance Schedule - Lennox Hearth Products MPD33RNM Care And Operation Instructions Manual

Merit pus series mdp direct-vent gas fireplaces
Table of Contents

Advertisement

LENNOX HEARTH PRODUCTS • MERIT PLUS

MAINTENANCE SCHEDULE

Annually (Before the onset of the Burning Season)
Maintenance Task
Inspect and Clean Burner, Logs
and Controls
Check Flame Patterns and Flame Height
Inspect and Clean Pilot and Burner
Check Vent System
Appliance Checkout
Replace Glowing Embers
Periodically (After the Burning Season)
Maintenance Task
Clean Firebox Interior
Check Flame Patterns and Flame Height
Check Vent System
Clean Front Glass Enclosure Panel
DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS
®
Accomplishing Person
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Services Technician
Accomplishing Person
Homeowner
Homeowner
Homeowner
Homeowner
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Procedure
Inspect valve and ensure it is properly
operating. Check piping for leaks. Vacuum
the control compartment, fireplace logs and
burner area.
Refer to Figures 10 (MPD33), 11 (MPD35) or
12 (MPD40 & MPD45) on page 16 and verify
the flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the logs. Ensure flames
are steady (not lifting or floating).
Refer to Figure 13 (SIT) or Figure 14
(Honeywell) on page 17. Remove any surface
build-up on pilot and burner assembly. Wipe
the pilot nozzles, igniter/flame rod and hood.
Ensure the pilot flame engulfs the flame sensor
as shown.
Inspect the vent system at the top and
at the base (within the firebox) for signs
of blockage or obstruction. Look for any
signs of dislocation of the vent components
(reconnect or replace as necessary).
Perform the appropriate appliance checkout
procedure detailed in this manual.
Remove old ember materials and vacuum
the rockwool placement area. Place new
rockwool as described in this document.
Procedure
Carefully remove logs, glowing embers and
decorative volcanic stone. Vacuum out interior
of the firebox. Clean firebox walls and log grate.
Replace logs, glowing embers and volcanic
stone as detailed in this manual.
Refer to Refer to Figures 10 (MPD33),
11 (MPD35) or 12 (MPD40 & MPD45) on
Page 16 and verify the flame pattern and height
displayed by the appliance conforms to the
picture. Flames must not impinge on the logs.
Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of dislocation
of the vent components (reconnect or replace as
necessary).
Clean as necessary following the directions
provided in this manual. DO NOT TOUCH OR
ATTEMPT TO CLEAN GLASS WHILE HOT.
25

Advertisement

Table of Contents
loading

Table of Contents