If additional user manuals are needed talk to your distributor or visit the Culinaire website. Do NOT store or use gasoline or other flammable vapours or liquids in the vicinity of this or any other appliance.
Specifications Introduction The Culinaire Warming Drawer unit has been specifically designed to meet the rigorous demands of a busy food service operation. The unit is manufactured from high quality 304 grade, 1.2mm stainless steel, and has been designed to hold bulk foods above 65 C to meet minimum health requirements.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Technical/Connection Diagram Due to continuous product research and development, the information contained herein is subject to change without notice Tel: 1300 79 1954 Web: www.stoddart.com.au Email: fse@stoddart.com.au Revision Date:18/04/2012 Version 3 Page 6...
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Rating Plate The rating plate of the appliance contains identification and technical data and is located as indicated below. Sample Only Due to continuous product research and development, the information contained herein is subject to change without notice Tel: 1300 79 1954 Web: www.stoddart.com.au...
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Installation General Precautions WARNING! Installation must comply with local electrical and health & safety requirements. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Do NOT use this appliance for other than its intended use.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Setting Up Handling Use suitable means to move the appliance: eg. A lift truck or fork pallet trucks (the forks should • reach more than halfway beneath the appliance). Site Preparation Ensure the site is level and properly cleaned.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Electrical WARNING! This unit MUST be installed in accordance with AS/NZS 60335.1 and complies with local laws Power Supply The appliance is supplied with a 3-core, 240 Volt, 10 Amp, 2.3m flexible power cord with a standard 3 pin plug.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Operation General Recommendations When using any electrical appliance, safety precautions should always be observed. Our appliances have been designed to give high performance. Hence, the appliance must be used exclusively for the purpose for which it has been designed.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Unit Operation Power The unit can be switched ON or OFF with the POWER button on the front of the unit. • The POWER button is a protection switch. No other switch can operate if the POWER button is OFF.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Drawer Operation Initial Start up Before switch ON the unit, ensure the unit is installed correctly. • Switch ON and check the drawers are heating up. • Check the temperature after 45 minutes to ensure the unit has reached operating temperature.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Cleaning WARNING! Switch the unit OFF at the main power supply before cleaning. Schedules After use, the gastronorm pans should be cleaned STRAIGHT AWAY. • The unit should be cleaned at the end of the EVERY WORK DAY.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Maintenance Routines Schedules To maintain optimal performance, maintenance and cleaning schedules must be regular and thorough. • After use, the gastronorm pans should be cleaned STRAIGHT AWAY. • The unit should be cleaned at the end of the EVERY WORK DAY.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Stainless Steel Protection Cleaning For cleaning the stainless stain, check the cleaning section of the operation manual. • All metal surfaces should be checked while cleaning for damage, scuffs or scapes as these can lead to rust •...
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Access to Electrical Wiring and Mechanical Parts (Qualified Technician Only) WARNING! Switch the unit OFF at the main power supply before any maintenance or servicing. Electrical Junction Box The electrical junction box has the switches on the face, and contains main wiring to the unit inside.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Replacements Gastronorm Pans Gastronorm pans can be replaced by others. • Runners Runners and drawers can be replaced by the manufacturer. • The runners and drawers MUST be replaced by a qualified technician.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Troubleshooting WARNING! Technician tasks are only to be completed by qualified service people. Check faults before calling service technician. Task Type - (O) = Operator (T) = Technician Task Check for faults before calling service technician...
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Electrical Diagram Due to continuous product research and development, the information contained herein is subject to change without notice Tel: 1300 79 1954 Web: www.stoddart.com.au Email: fse@stoddart.com.au Revision Date:18/04/2012 Version 3 Page 20...
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 Spare Parts/Assembly Diagram Due to continuous product research and development, the information contained herein is subject to change without notice Tel: 1300 79 1954 Web: www.stoddart.com.au Email: fse@stoddart.com.au Revision Date:18/04/2012 Version 3...
Warranty Australian Warranty and Contact Details As the exclusive manufacturer and distributor of Culinaire products in Australia, Stoddart Manufacturing (Stoddart) would like to congratulate you on your purchase of a Culinaire product. It should be noted by users of the product that it is not designed for household or domestic use and should not be used for this purpose.
INSTALLATION, OPERATION & MAINTENANCE Culinaire Warming Drawers CWD2.1/1 3.2. Stoddart's warranty liability under clauses 1 and 2 of these Terms exclude or do not cover: i. The matters acknowledged by Customer in clause 3.1; ii. Situations where Stoddart is not satisfied (acting reasonably) the equipment or any part of the equipment has been used in accordance with the Instructions including misuse, neglect, unauthorised alteration, incorrect installation, power surges, accident, use of inappropriate chemicals, flooding, fire or act of God;...