INSTALLATION

1. Turn off power to the air handling system at the circuit breaker.
2. Draw a level line on the plenum in the selected location.
IMPORTANT
To ensure optimal product performance, be sure the mounting template is
level before marking. Use of a small level is recommended.
3. Locate the template (form number 69-2710 included in the box). For the HE240
model, cut out the template along the dotted line.
4. Tape the template in position and trace around the template.
5. Remove the template and carefully cut the rectangular opening using tin snips.
6. Disassemble the humidifier; remove the cover and take out the humidifier pad
assembly. See Fig. 4.
COVER
SIDEWALL
BY-PASS SIDEWALL
HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
WATER
FEED NOZZLE
PerfectFLO™ WATER
DISTRIBUTION TRAY
HUMIDIFIER
PAD ASSEMBLY
FRAME
HUMIDIFIER
HOUSING
WATER
FEED TUBE
Fig. 4. Disassembling humidifier.
7
SOLENOID VALVE
PRESSURE SWITCH
M33323