1.2 Mechanical Characteristics ing power for video and processing control from this connector. (Strobe circuits obtain dedicated The 6110 has optical and mechanical inter- power from the RJ-45 connector.) faces identical to the Cohu model 2600 camera. It can be mechanically substituted in place of a 1.1.3 RJ-45 10 Wire Connector...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Table 1. Specifications E L E CT RICAL S ensor 1/2-inch form at 4.65 m icron x 4.65 m icron A ctive P ixels 1360 (H) x 1024 (V ) Resolution 1024 x 1024 tv lines...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION 611 2 — 1 00 0 xxxx Series Power Assigned Monochrome 2 12 V dc over 2k Camera IEEE-1394a Accessories 0 None Sensor Camera Output Lens 1 1/2-inch format monochrome Option 1 IEEE-1394a...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Table 2. Key Points to Remember IT E M K E Y P O IN T S S TR O B E O U TP U TS U s ing the s tro b e o utp uts re q uire s a c a b le w ith a n R J -4 5 c o nne c to r...
Interface (emitter follower to interface with camera. This can include the driven) DRIVERS Cohu 6110 GUI interface, third-party software Note: External emitter such as National Instruments Lab View, or software resistors required written or modified for the specific application. Illumination...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION CAMERA 10-PIN RJ-45 Opto-isolated Board CONNECTORS Strobe 4 Strobe 4 Out Emitter Followers Strobe 3 Strobe 3 Out Strobe Outputs from Camera Strobe 2 Strobe 2 Out Load Resistor Required Strobe 1...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Table 3. Items Supplied Table 4. Item Typically Required But Not Supplied ITEMS SUPPLIED ITEMS TYPICALLY REQUIRED BUT NOT SUPPLIED Cohu Part Item Description Number ITEM Description Characteristics Kit 8366-7 Supplied Items...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION CAMERA Table 5. Cables Required Rear Panel RJ-45 C A M E R A M AT IN G Opto-isolator Connector D E S C R IP T IO N C O N N E C TO R...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Table 6. Drop-down Menu Selections Camera Mode Cohu Help Rate Camera Reset About 1394Cohu Demo... 1280x960 Mono (16-bit) 7.5 pfs Check Link Debug Setting Select Camera Set Serial Number Init Camera Partial Scan...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION A. NO SHUTTERING 250 ms Full Exposure Period EXPOSURE TIME Strobe timings must be set to illuminate the scene during this interval. 250 MS STROBE TIMES SHOWN DURING 10 INTERVALS WITHOUT SHUTTERING B.
Software Control Viewer software must be used to control 2.6.4 Strobe Timing Reference most camera functions. The Cohu 6100 GUI Viewer can be used for basic control functions or The strobe outputs must have their timings a third-parts software such as National Instru- set (figure 22) to produce scene illumination ments Lab View can be used.
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION A. Available Strobing Interval Without Shuttering Strobe Reference Edge Sensor Vertical Integration Interval Strobe Start-time Forcible End of Strobe Period if Stop is Set Beyond Here Start and Stop of Strobe Selected Start of Strobe Period...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION 3.5.9 Camera Control . . . 3.5.1 Check Link Opens up a new window (figure 16) with This selection (figure 17) causes the Viewer slider bars to control Shuttering, Gain, and software display all available cameras on the Brightness.
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Table 7. “Camera” Drop-down Menu Items ITEM NAME FUNCTION Check Link Polls IEEE-1394a for all available cameras Select Camera Opens a window to select the desired camera from a list Init Camera...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Figure 12. “Camera” Window (with typical selections) When this menu item is selected, three other choices become available: Positive Edge, negative edge, and Both. (Both is a special function.) 3.5.15 Positive Edge...
Cohu Drop Down Menu Items This is the maximum full-frame mode for the camera. The grayed-out selections apply to other Two selections are available under the Cohu cameras. The frame rate at full scan is four drop down menu. frames per second. An increased frame rate can be obtained by using the Partial Scan mode.
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Figure 15. Camera Window After Init Cam- Figure 14. Camera Window with Select era Selected Camera Selected 3.9.2 Debug Settings Opens a new window (figure 23) with two slider bars. The top bar for DLL Trace Level is currently implemented.
See section 2.8.4. mized. The Shuttering bar reduces the amount of 3.10.3 Cohu Set Serial Number time the sensor is allowed to integrate an image. Note: Do not click this selection before When any frame rate is established for the...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Figure 17. Check Link Verify Window Figure 18. Maximum Speed Window (IEEE-I394 Maximum Bit Rate) aged condition, apparent or concealed, a claim for damage must be made to the carrier. If a visual inspection shows damage upon...
Preliminary 3a 4-14-05 6110 CAMERA INSTALLATION AND OPERATION Figure 24. Set Serial Number Window This list serves as a reminder of the mini- mum acceptable practices. Be sure that all static discharge devices at the work bench are properly installed and maintained. Standard grounding Figure 23.
Cohu, in no event, whether as a result of breach of contract or warranty, tort (including negligence) or otherwise, shall be liable for any penalties regardless of reason;...
Need help?
Do you have a question about the 6110 and is the answer not in the manual?
Questions and answers