Mounting Procedure - ADS-tec OPC5012 User Manual

Industrial pc
Table of Contents

Advertisement

Industrial PCs OPC5012
3.3 M
OUNTING PROCEDURE
Warning:
The cutout is different for an OPC with a 24 V DC connection.
Overtightening the screws could bend the faceplate out of shape beyond repair and break
the glass in touch screen devices.
Note:
The device is connected to the power supply using the accompanying power cable or a
lead out terminal with a screw connection. A ground connection does not have to be
made, because the grounding conductor of the device plug or supply connection serves
this purpose. If additional grounding conductors are attached to a grounding screw, a
wire diameter of at least 2.5 mm² is specified.
© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen
Cut out the section or the control panel or cabinet door as shown in the
illustration.
Slide the device into the cutout from the front (place the ON/OFF switch of an OPC
with 24 V DC to the center position).
Insert the fastening bolts with slot nuts in the matching slots in the sheet metal
cover and then tighten the screws on all bolts equally (max. torque 25 Ncm) until
the faceplate is pulled into place in the cutout.