REPLACING THE FEED ROLLERS...........8 REPLACING THE DRIVE BELTS ............9 REPLACING THE MAIN PCB............10 5.4 REPLACING THE DISPLAY PCB .............10 REPLACING THE POWER PCB ............11 REPLACING SENSORS ..............11 SENSOR POSITION PICTURE............11 REPLACING OTHER PARTS............12 PARTS LIST AND PICTURES.............12 Adam Equipment Company 2012...
Press this key to decrease the quantity in the BATCH display. It can also be used to select settings in the parameter section. Press this key to select detection using the Magnetism sensor. [MG] Press this key to select detection using the Ultra Violet sensor. [UV] Adam Equipment Company 2012...
Main display will display a flashing figure of how many notes have been counted so far. Place more notes into the machine to continue until the BATCH figure is reached. Press the [BATCH] key to return to normal counting and the LED will go out. Adam Equipment Company 2012...
The Main display will accumulate all countings and give a total count at the end and the Batch display will show the required Batch quantity. Adam Equipment Company 2012...
When a detection for any of these have been made please note that the faulty note will still have been included in the total count on the Main display. Remove the faulty note and press [START] to resume counting. Please see error code table in section 6.2 for more details. Adam Equipment Company 2012...
1 = LOWEST 10 = HIGHEST OFF AND 1-10 OP-B MG SENSITIVITY 1 = LOWEST 10 = HIGHEST OP-D SIZE DETECTION AUTOMATIC OR YES = AUTOMATIC OP-E NO = MANUAL MANUAL INCLUDE OP-U DUBIOUS NOTE IN TOTAL Adam Equipment Company 2012...
DUBIOUS NOTE DETECTED BY MG SENSOR PRESS [START], CHECK THE MG SENSITIVITY SETTING DUBIOUS NOTE DETECTED BY SIZE REMOVE THE NOTE AND DETECTION SENSOR PRESS [START] DUBIOUS NOTE DETECTED BY CHAIN NOTE REMOVE THE NOTE AND DETECTION SENSOR PRESS [START] Adam Equipment Company 2012...
5 x screws that attach each one. Remove the circlip at each end of the shaft and push the shaft through to enable easy removal of the feed rollers. Removing the large drive belt may also make this easier to do. Adam Equipment Company 2012...
Remove the right side cover to expose the drive assemblies. Pull the old drive belts from the wheels and replace with a new one making sure that the drive belts are situated correctly on the wheels then replace the cover. Adam Equipment Company 2012...
Remove the 5 x screws to expose the display PCB. Remove the 6 x PCB fixing screws and connector from the PCB and replace the PCB. Refit the cable connector, screws and housing. Adam Equipment Company 2012...
The UV, MG and also the LEFT and RIGHT sensors can be changed by accessing them from the front and also from the top of the machine. The display unit will need to be pulled forward to expose the top part for access. SENSOR POSITION PICTURE Adam Equipment Company 2012...
NCSA 20plus FEED ROLLERS (SET OF) 7.00.2.3.0010 NCSA 20plus LARGE DRIVE BELT 7.00.2.3.0011 NCSA 20plus SMALL DRIVE BELT 7.00.1.0.0293 NCSA 20plus LEFT AND RIGHT SIDE SENSOR (x2) 7.00.1.0.0294 NCSA 20plus MG SENSOR 7.00.1.0.0295 NCSA 20plus UV SENSOR 7.00.1.0.0296 NCSA 20plus START SENSOR 7.00.1.0.0297...
Page 14
MAIN PCB SPEED SENSOR DRIVE BELTS Adam Equipment Company 2012...
Page 15
POWER PCB MOTORS Adam Equipment Company 2012...
Page 16
WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company.
Page 19
Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment WEEE COMPLIANCE...