Input voltage
Power
Ambient temperature
Humidity (condensed)
Focus (median range of light)
Dimmer range (internal)
Weight
Connector
Mounting
Subject to technical change.
Only use the light when level! Operation in a vertical state does not correspond
with the specification.
The product does not include any parts requiring maintenance.
If there is a problem, please check the following items first:
Error
Does not light up
Too dark
Cuts out
If this does not solve the problem, please do not hesitate to contact us on
+ 49 [0] 89/27 81 82 82 .
11–28V
16W
20°C normal
max. 50°C,
min. -20°C
- 80% rel. humidity
40°– 60°
10–100%
495 g (incl. 2-leaf barn doors)
AB-DTAP, XLR on request
double-articulation system
Cause
Power switch not on
Incorrect input voltage
Cable damaged
Dimmer low?
Input voltage too low
Filter blocking light
Cable damaged
Dirty contact
TECHNICAL SPECIFICATION
TROUBLESHOOTING
11