Table of the Contents Table of the Contents ....................1 Introduction ......................... 1 Precautions ......................... 1 Maintenance........................ 2 Calibration and Repair Philosophy ................2 Technical Support ......................3 Feedback to Us ......................3 System Overview ......................3 System Configuration ....................3 Technical Specification ....................
User Manual Introduction This publication provides the necessary information required to safely operate the -1 Thermal Camera. EASIR -4/ EASIR -2/ EASIR It is important to fully check all equipment with which you have been supplied. The equipment should be used, maintained and serviced by suitably trained personnel, capable of carefully following the procedures and guidelines given in this User Manual.
User Manual FPA setting: to ensure accurate temperature measurement, the FPA detector was • calibrated in different temperature points--7degree, 17degree, 27degree, 37degree. When power on the camera in 0 degree for example, after period of working the temperature of the camera (the detector) will increase gradually. And when the internal temperature of the camera beyond 7 degree, FPA setting will take place and will last for about 30sec, and during the FPA setting the camera will not response for any operations.
Technical Support Technical support for your Wuhan Guide Thermal Imaging System can be obtained by either contacting the address / telephone number on the cover of this User Manual or by email to the following address: overseas@guide-infrared.com Feedback to Us We have tested and verified the information in this manual to the best of our abilities.
User Manual ® • Guide IrAnalyser Software • User manual • Wrist strap • Safety case • Soft bag Options • 30mm Tele lens • 7mm wide angle lens • Extended temperature range up to +350℃ • 1200℃ high temperature filter •...
Page 8
User Manual ® Menu: Microsoft Windows style Measurement Temperature Range: -20℃ to 250℃ (350℃,optional) -20℃ to 250℃ Accuracy: ±2℃ or ±2% of reading Emissivity Correction: Variable from 0.01 to 1.00 (in 0.01 increment) Measurement Features: Automatic correction based on distance, relative humidity, atmospheric transmission and external optics Optics Transmission...
User Manual System Features Features Advantages Benefit Speedy 50 Hz or especially in cold outdoor climates, hand shakes 60 Hz. IR makes sharp IR images do not appear on IR images camera fast (ZipZip) and best focus by Auto focus for pressing one button only –...
Page 10
User Manual Rugged and ergonomical easy to hold and carry easy your inspection work design overlays the thermal image directly on the corresponding visual image InfraFusion helps to identify where the problem exactly is for comparison and problems locating Versatile accessories 1.Tele lens, wide angle lens, high...
User Manual Trigger Button USB Interface Video Interface AC Adapter/Charging Input Terminal SD Card Slot Charging Instruction Note: “slow flicker” in the text is about 1 time per second, “quick flicker” is about 3 times per second. How to use the adapter The red indicator light will turn on when the adapter is connected with camera.
User Manual Note: The batteries cannot be taken out of the camera in the charging process. The temperature will be relatively high when it reaches to fully charging, if the red indicator flickers quickly during the power on reset (to remove and insert the adapter), it indicates the battery temperature is overly high and the charging process should be stopped.
Page 14
User Manual Auto/manual mode switch When there is no menu on the screen, keep button depressed to switch between the manual mode and automatic mode. AutoSpan ManualSpan Enter PIC mode When there is no menu on the screen, press button to enter PIC mode, the following info will be displayed on the screen :...
Page 15
User Manual When there is no menu on the screen, keep button depressed for 2 seconds to turn on /off the laser (Ensure the Laser is “Enabled” in the menu Parameter) Manual calibration When there is no menu on the screen, keep button T and button depressed at the same time to calibrate with shutter When there is no menu on the screen, keep button T and button...
Page 16
User Manual Press button to enter visual mode, press again to return real-time IR mode. Press button T to return to real-time IR mode. Main menu operation When there is no menu on the screen, press button to bring up Main menu, the following info will be displayed on the screen:...
User Manual Lang Tunit TimeDate PAL/NTSC AlamTemp ↑ ↓ In the sub-menu Setup, press button to confirm the highlighted option and enter the next sub-menu, press button T to return to real-time IR mode. Function operation Thermal camera focusing There are two methods to adjust focus: motorized and automatic To motorizedly focus: Aim the lens at the target Press...
Page 18
User Manual Press button to enter Parameter Select sub-menu Palette Press button or button to shift among different palettes Press button to confirm. Setting Tmin and Tmax When there is no menu on the screen, keep button depressed to switch between the manual mode and automatic mode.
Page 19
User Manual Press button and button to adjust the InfraFusion percentage. Reviewing and Deleting Saved Images To view saved images in the SD card: Press button to activate the menu. Press button to activate sub-menu File. Press button to enter the Filelist. Press button and button to switch among different images, and press...
Page 20
User Manual Emissivity: All objects radiate infrared energy. The amount of energy radiated is based on two primary factors: the surface temperature of the object and the emissivity of object’s surface. The default emissivity is 0.98, which is applicable to most surfaces. For some special materials or surfaces, please refer to the emissivity table to find a right emissivity value.
Page 21
User Manual ↑ ↓ Press button or button to select PAL/NTSC, and press button to cancel. NTSC When viewing the live image on external monitor, the camera screen will become black, but you can still use the buttons to control the camera. After viewing the live image, power off the camera, monitor (or recording device) and disconnect the cable.
Page 22
User Manual where the films are saved Device Video Make sure the camera is under normal working status and connect the with the PC via USB2.0 to activate this command; it will bring a dialog box as following Select and press ok to confirm, the infrared video is open as following Open Film Use this command to open the saved Video file in the directory path of PC.
Page 23
User Manual Film: set the directory path to save the video recording Capture Saved: set the directory path to save the captured image Frame Rate: set the frame of thermal image per second. The default value is 25/ second Kinescope Rate: set the frame of thermal video. The default value is 1 frame. Update track view: update the interval between track circles Default Palette: set the palette to be used for the infrared video After saving the setup, the program will automatically go to the directory when opening...
Page 24
User Manual Auto adjustment command Use this command to choose adjust image color automatically or manually. Auto adjustment: the system mapped every image to the appointed pseudo color according to its temperature. Manual adjustment: mapped the temperature range to the appointed palette via appointing the maximum and minimum temperature, then the image will be displayed.
Page 25
User Manual Save as .IRI file or .JPG file to the appointed directory path Open as new .IRI or .JPG file Save as .IRI file or .JPG file and open it Note: The file format is .JPG Auto focusing command When playing infrared video, use this command under Video Menu or Press Ctrl + F to perform auto functions operation on camera.
Page 26
User Manual the PC. Images saved in UFLASH can be transferred to PC via IrAnalyser. • If SD card is inserted in camera, the PC will identify the camera as a removable hard disk, you can copy the saved data to PC or delete them from the card, or even format the SD card and etc.
Page 27
User Manual Installation starts. When getting to the step as shown below, choose “Continue anyway” to proceed further. Installation continues and finishes quickly. Click button Finish.
Page 28
User Manual Go to Device Manager to check and confirm whether the driver has been successfully installed. If there is a listed under Universal Serial Bus Controller, it indicates the driver has been properly installed and you can transfer data from the camera to PC now. The procedures to go to Device Manager is as follows: Clicking My Computer->...
Need help?
Do you have a question about the EasIR-4 and is the answer not in the manual?