INSTALLATION AND
MAINTENANCE MANUAL FOR GAS
FIRED HEATER
SF 16 E
Model
TYPE C
ROOM SEALED
CE
0694
Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY
ENGLISH
By Technical Department

Advertisement

loading

Summary of Contents for Radiant SF 16 E

  • Page 1 INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED HEATER SF 16 E Model TYPE C ROOM SEALED 0694 ENGLISH Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY By Technical Department...
  • Page 3: Table Of Contents

    INDEX INSTALLATION INSTRUCTIONS AND WARNINGS page TECHNICAL DATA page OVERALL DIMENSIONS - EXHAUST FLUE SYSTEM page GENERAL INSTALLATION REQUIREMENTS page BOILER INSTALLATION page GAS OPERATIONS AND ADJUSTMENTS page REGULATING THE GAS PRESSURE page ELECTRICAL CONNECTIONS page 10-12 BOILER CONTROL PANEL page STARTING UP THE BOILER FOR THE FIRST TIME page...
  • Page 4: Technical Data

    Declaration for purposes of Art. 7 of Law 46 of 5 April 1990. RADIANT BRUCIATORI S.p.A. hereby declares that all of its products are constructed to industry standards as required by the Article in question and by Article 5 of the law in effect (D.P.R. no. 447/97).
  • Page 5 CENTRAL HEATING – D.H.W. room sealed circuit type mod. RBS 20 E Coaxial vertical C52 Double Coaxial horizontal Technical data Model SF 16 E BTU/h Maximum Rated Output 85275 Maximum Rated Output 13.2 45025 Maximum Rated Input 29.7...
  • Page 6 0.5 m. SF 16 E NOTE: USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS, FLUE ACCESSORIES AND FLUE DIAPHRAGMS ONLY. APPROVED RADIANT FLUE DIAPHRAGMS AND ADJUSTMENT TABLES ARE SUPPLIED WITH RADIANT ORIGINAL FLUE KIT SYSTEMS. Gas Fire Heater – Cod. 99962NA – November 2002...
  • Page 7: General Installation Requirements

    Installation Manual GENERAL INSTALLATION REQUIREMENTS GAS SAFETY It is the law that all gas appliances are installed by a CORGI registered installer (you can check this by contacting corgi on 01256.372200) in accordance with the regulations listed below. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to ensure that the law is complied with.
  • Page 8 Installation Manual Where installation will be in an unusual location, special procedures may be necessary. BS 6798 gives detailed guidance on this aspect. For clearances to be made available for installation and servicing, see Sections 5.2.2. to 5.2.4. FLUE POSITION IMPORTANT: THE FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS CONTAINED IN BS 5440:1.
  • Page 9 Installation Manual DISTANCES FOR FIXING TO WALL The water heater must be installed in a suitable wall. The water heater must not be fitted in a cupboard or cabinet and to allow access for maintenance operations, the minimum distances shown below must be respected.
  • Page 10 Installation Manual WATER AND GAS CONNECTION For the installation respect national standards and safety norms. GAS CONNECTION - The pipe must have sufficient section with respect to its length and to necessary flow rate, and must be equipped with all the safety devices and controls required by the law.
  • Page 11: Gas Operations And Adjustments

    Installation Manual GAS OPERATION AND ADJUSTMENTS GAS RAMPS Conversion of the water heater from NATURAL GAS to LPG and vice versa must be performed by qualified personnel only. Conversion is performed as follows: 1 - Make sure to disconnect the power supply and that the gas tap is closed.
  • Page 12 Installation Manual Fig. 2/1 Selector Selector Collector Collector Original selector Selector position position during gas pressure setting Fig. 2 POST-VENT Maximum gas pressure adjusting screw Gas burner pressure point F1 2AT Inlet gas pressure point Minimum pressure mechanical adjustment Selection for electrical and mechanical minimum pressure adjusment Natural Gas - LPG link Fan over-run adjustment...
  • Page 13: Electrical Connections

    Installation Manual ELECTRICAL CONNECTIONS The boiler works with 230 V 50 Hz AC current and has maximum input of 170 W. Connection to the electrical mains must be performed with a device having an omnipolar opening of at least 3 mm. Make sure the live and neutral connections conform to the diagram.
  • Page 14 Installation Manual ELECTRIC WIRING DIAGRAMS Gas Fire Heater – Cod. 99962NA – November 2002...
  • Page 15: Installation Manual

    Installation Manual W4115CM-1022 566057 0009 9847 Gas Fire Heater – Cod. 99962NA – November 2002...
  • Page 16 Installation Manual INSTRUMENT PANEL Legend: ON/OFF SWITCH D.H. WATER TEMPERATURE SETTING KNOB (40 - 60 °C) POWER INDICATOR D.H.WATER OPERATION INDICATOR RESET BUTTON Fig. 1 PRELIMINARY OPERATIONS Make sure that the gas cock and all water taps are closed. Open the cock for the gas counter or for the liquid gas tank meter. Open the gas cock (not supplied as standard) located immediately upstream of the heater on the gas intake pipe.
  • Page 17 Installation Manual MALFUNCTION POSSIBLE CAUSE REMEDY The water heater doesn’t work Rotative flow meter Replace it Gas and water tap opened _D. Hot Water 1/8” sensor _Replace it Power indicator ON _Fuse _Replace it D. Hot Water operation indicator OFF _Main Circuit Board (See table 1) _Replace it The water heater doesn’t work...
  • Page 18: Unpacking

    Installation Manual UNPACKING Set the packed water heater on the floor. Make sure the arrow is pointing up. Remove the tape and open the 4 flaps toward the outside. Remove the inside cardboard packing. Hold the water heater from the rear (frame) when lifting. IMPORTANT ! The packing material (cardboard) is recyclable.
  • Page 20 • Internet: http://www.radiant.it UK – Radiant Helpline – 01329.828555 All descriptions and illustrations contained in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products whitch may affect the accurancy of the information contained in this leaflet. E + OE All rights reserved.