Do you have a question about the Lady Kitchener AG 08 DRYBACK and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Firenzo Lady Kitchener AG 08 DRYBACK
Page 1
Please read this booklet and keep for future reference for the safe installation of your: LADY KITCHENER 08 DRYBACK MODEL: FREESTANDING WOODBURNER All installations must be in accordance with these instructions. Consult with the building authority having jurisdiction to determine the need for a permit prior to commencing the installation.
Page 2
INDEX Page No: Item No: Topic: Warnings Installation Responsibilities Floor Protector Requirements Installation Clearances Assembly Instructions Fitting Seismic Restraints Flue Installation Minimum Height of Flue System Exit Triangular Baffle Bricks Edited 16/11/2012 Lady Kitchener AG08 Dryback...
Page 3
THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS. The Lady Kitchener AG 08 Dryback has been tested to N.Z. Standards AS/NZS 2918:2001. If this heater is incorrectly installed a house fire may result. For your safety follow the installation instructions carefully.
2. INSTALLATION RESPONSIBILITIES WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZ 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013.
FLOOR PROTECTOR DIMENSIONS: Refer to drawings under 4.Installation Clearances. The standard front clearance from the front of the door glass can be reduced by increasing the insulated floor protector height, as tabled below: FLOOR PROTECTOR HEIGHT F/P DEPTH FOR PED OR D/BASE F/P DEPTH FOR LEG BASE 4.
Page 6
5. ASSEMBLY INSTRUCTIONS 1. Remove all packaging and timber. 2. Remove parts from inside the firebox. 3. Remove both front and rear top castings. 4. Make sure baffles and triangular bricks are positioned as in diagram on page 11. 5. Place pedestal/drawerbase onto floor protector, fit firebox on top of same. The leg model comes assembled so place complete unit on the floor protector.
FITTING SEISMIC RESTRAINT BRACKETS ON LADY KITCHENER AG PEDESTAL OR DRAWER BASE MODELS 1. Remove bolts at rear of fire box 2. Fit Seismic Restraint brackets 3. Secure both the floor protector and the appliance to the floor. LEG MODELS 1.
Page 8
6. FREESTANDING FLUE SYSTEM INSTALLATION INSTRUCTIONS 1. Position heater on floor protector ensuring all heater clearances are correct as per clearances on page 5. 2. Once the location is confirmed, the appliance and floor protector shall be fixed to the floor itself (refer to page 6 &...
Page 9
WARNING: The appliance and flue system shall be installed in accordance with AS/NZS 2918:2001 and the appropriate requirements of the relevant building code or codes. Lady Kitchener AG08 Dryback...
Page 10
LADY KITCHENER AG08 DRY IMPORTANT UPON INSTALLATION CHECK THAT THE TRIANGULAR BRICKS ON TOP OF THE BAFFLES ARE PLACED AS SHOWN Lady Kitchener AG08 Dryback...
Page 11
FIRENZO WOODFIRES Hewitsons Limited Manufacturers of: Lady Kitchener Bronte Contessa Royale Zealandia Encore Coaster Athena Forte Deco Plaza Aqualux Kompact 98 Niven Street Onekawa PO Box 3231 Napier 4142 Phone: 06 8438260 Fax: 06 8430505 Email: hothouse@firenzo.co.nz www.firenzo.co.nz Lady Kitchener AG08 Dryback...
Need help?
Do you have a question about the Lady Kitchener AG 08 DRYBACK and is the answer not in the manual?
Questions and answers