AirStage UTY-DTGY Installation Manual

Touch panel controller

Advertisement

Quick Links

UTY-DTGY
UTY-DTGG
INSTALLATION MANUAL
TOUCH PANEL CONTROLLER
For authorized service personnel only.
MANUEL D'INSTALLATION
CONTRÔLEUR DE PANNEAU À CONTACT
Uniquement réservé aux techniciens agréés.
MANUAL DE INSTALACIÓN
CONTROLADOR DE PANEL DE CONTACTO
Sólo para personal de mantenimiento autorizado.
MANUAL DE INSTALAÇÃO
CONTROLADOR DE PAINEL DE TOQUE
Apenas para técnicos de assistência autorizados.
安装说明书
触摸屏控制器
只适用于专业维修人员
PART NO. 9378850019

Advertisement

Table of Contents
loading

Summary of Contents for AirStage UTY-DTGY

  • Page 1 CONTRÔLEUR DE PANNEAU À CONTACT Uniquement réservé aux techniciens agréés. MANUAL DE INSTALACIÓN CONTROLADOR DE PANEL DE CONTACTO Sólo para personal de mantenimiento autorizado. MANUAL DE INSTALAÇÃO UTY-DTGY CONTROLADOR DE PAINEL DE TOQUE Apenas para técnicos de assistência autorizados. UTY-DTGG PART NO. 9378850019...
  • Page 2: Table Of Contents

    INSTALLATION MANUAL ▪ Area that generates substances that adversely affect the equipment, such as sulfuric gas, chlorine gas, PART NO. 9378850019 acid, or alkali. It will cause the copper pipes and TOUCH PANEL CONTROLLER brazed joints to corrode, which can cause refrigerant Contents leakage.
  • Page 3: Electrical Requirement

    SELECTING AN INSTALLATION LOCATION Operating Instruction book for manual operation 41 11 Dimensions Include the operating CD-ROM ▪ Touch panel controller main unit and installation plate manual for this control- Top view Unit:mm (in.) Installation plate For Touch Panel Con- troller installation (it is USB port Front cover...
  • Page 4: Installing The Touch Panel Controller

    ▪ Installation layout 51 11 Installation preparations When installing the touch panel controller, installation layouts such as these are not allowed. ▪ Make ready the touch panel controller. Left-right sideways Reversed installa- Flat installation Side view Front view Side view installation prohibited tion prohibited prohibited...
  • Page 5: Terminal Names

    cover. (Fig. 3) Remove the screw at 2 places of the  wiring CN411 CN412 hole and remove the wiring hole cover. (Fig. 2) Fig1 Unit: mm (in.) Rear cover outline 123 (4-27/32) [TM201] 95 (3-3/4) 95 (3-3/4) 72 (2-27/32) 72 (2-27/32) EXTERNAL INPUT TRANSMISSION 46 (1-13/16) 46 (1-13/16)
  • Page 6: Wiring

    Operates from de-energized state Emergency stop TM201 to energizing 300ms or more or batch start between K1 and K2 of CH1. Pulse Operates from de-energized state Emergency to energizing 300ms or more stop reset between K1 and K2 of CH2. or batch stop Select Edge/Pulse by installer setting after turning on the power and starting the application.
  • Page 7: Installation Method

    Fig1 Perform wiring so that water does not enter this unit External terminal block along the external wiring. Always install a trap to the wiring or take other countermeasures. Otherwise it will Refrigerant cause trouble, electric shock, or fire. system 1 Confirm the name of each unit and name of each terminal block of the unit and connect the wiring in accordance with the directions given in the manual so...
  • Page 8: Turning On The Power

    Insert the connector of the connection cable. TURNING ON THE POWER Close the front cover and rear cover. Align the claw of the bottom of the front cover and fit the top to the rear CAUTION cover. Tighten the 2 screws at the side of the main unit.