Kathrein HDZ 100 Installation Manual
Kathrein HDZ 100 Installation Manual

Kathrein HDZ 100 Installation Manual

Caravan roof gland, protective casing for cable interfaces on the caravan roof for kathrein rotary antenna systems type cap series

Advertisement

Quick Links

Installation Manual
Caravan roof gland
HDZ 100
Protective casing for cable interfaces
on the caravan roof for Kathrein
rotary antenna systems type CAP series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HDZ 100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kathrein HDZ 100

  • Page 1 Installation Manual Caravan roof gland HDZ 100 Protective casing for cable interfaces on the caravan roof for Kathrein rotary antenna systems type CAP series...
  • Page 2: Table Of Contents

    ... 2 CONTENTS FOREIGN LANGUAGE INSTALLATION MANUALS/SERVICE ADDRESS OF THE SERVICE CENTRE HDZ 100 COMPONENTS/SCOPE OF SUPPLY HDZ 100 SCOPE OF SUPPLY ... 5 PROPER USE PROPER USE (USE FOR THE INTENDED PURPOSE) SAFETY INSTRUCTIONS - IMPORTANT NOTES ... 8 INSTALLATION EXAMPLES ...
  • Page 3: Foreign Language Installation Manuals/Service

    FOREIGN LANGUAGE INSTALLATION MANUALS/SERVICE Dear Customer, Chère Cliente, Cher Client, Gentile cliente, Estimado cliente, You can obtain an English version of our installation instructions from our representatives in your country (http://www.kathrein.de/include/kontakte_groups_eng.cfm?kontinent=1&gruppe=SAT) or download one from our homepage (http://www.kathrein.de/en/sat/products/englisch.htm). ADDRESS OF THE SERVICE CENTRE Electronic Service Chiemgau GmbH Bahnhofstraße 108...
  • Page 4: Hdz 100 Components/Scope Of Supply

    (Ø 5 mm) and one DC cable (Ø 6.5-7 mm) • The cables can optionally be fed downwards from the HDZ 100 casing into the vehicle interior or out from the casing to other points on the vehicle roof • Functionally appropriate sealing of the roof opening...
  • Page 5: Proper Use

    PROPER USE (USE FOR THE INTENDED PURPOSE) The HDZ 100 roof gland protects the cable connection point and the roof gland point when laying cables from CAP systems on the caravan or mobile home roof. The gland seatings are designed for two cables (Ø 5 mm) and one cable (Ø 6.5-7 mm).
  • Page 6: Safety Instructions - Important Notes

    Attention! Risk of death or injury due to possible roof collapsing and falling parts! Essential information The HDZ 100 should be fi tted only in a horizontal position. The correct execution of the installation and the electrical connections are important for safety.
  • Page 7 SAFETY INSTRUCTIONS - IMPORTANT NOTES Cables Lay all cables such that nobody can tread on them or trip over them. When connecting the power cables (receiver and turntable) to the vehicle electrical supply, make sure that the cable polarity is not reversed. If the cable polarity is reversed there is a risk of thermal overload and damage to components when the equipment is powered up! If cable ducts are used to protect the cables, up to a size of 31 x 17 mm they can be concealed in the...
  • Page 8: Installation Examples

    BASIC VARIANTS Roof gland with cable interface Roof gland without cable interface Cable continuation with cable interface CAP 600 CAP 700 CAP 600 CAP 700 CAP 600 CAP 700 CAP 900 CAP 900 INSTALLATION EXAMPLES Note: For the CAP 600/700 units there are always two cables emerging from the turntable.
  • Page 9: Installation And Connection

    INSTALLATION AND CONNECTION REQUIRED TOOLS AND EQUIPMENT • Circular cutter, Ø 38 mm • Cross-head screwdriver for M4 screws • Power drill • Twist drill Ø 2.5 mm • Knife • Round fi le or emery paper ® • Sikafl ex 291 sealant (included in the CAP turntable scope of supply.
  • Page 10: Installation Steps

    INSTALLATION AND CONNECTION INSTALLATION STEPS ROOF GLAND VARIANT In the centre of the intended position of the cable outlet spigot, drill the opening for the cable gland with a circular cutter (Ø: 38 mm). Deburr the hole with a round fi le or emery paper (see illustration on the right).
  • Page 11 INSTALLATION AND CONNECTION to the substrate. If the coat of paint is already loose or peeling, it must be removed down to a stable layer in the area to which the adhesive will bond. If you have any doubts concerning the adhesive characteristics, consult a paint and lacquer specialist, or the manufacturer of your vehicle.
  • Page 12: Cable Continuation Variant

    INSTALLATION AND CONNECTION 11. Use the plugs supplied to seal the cable attachment points that are now not required (see illustration on the right). Do not cut away any plugs that are not required, you will need them if you ever wish to remove the turntable system.
  • Page 13 INSTALLATION AND CONNECTION Continue as described in points 3. to 8. of the description for the “roof gland” variant. Now open up the break-out in the end face of the cover for the cable outlet (see illustrations on the right). 10.
  • Page 14 INSTALLATION AND CONNECTION 11. Insert the cable in the seal and push it into the cable clips in the casing (see illustration on the right). 12. Use the plugs attached to seal the cable attachment points that are now not required (see illustration on the right).
  • Page 15: Technical Data (In Mm)

    TECHNICAL DATA (in mm) Cable inlet Kabeleingang up to 3 cables bis zu 3 Kabel (3x) RAL 9002 (grey white) RAL 9002 (Grauweiß) Interfaces: Schnittstellen: - Roof hole: Ø 38 - Dachbohrung: - Cable duct: W=31, H=17 - Leitungsführungskanal: B =31, H =17 - Cables: 2x RF Ø...