    7602030 ASSEMBLY INSTRUCTIONS CONTENTS OF THE MANUAL 1. System supply condition Page 18 2. Positioning the lower rail Page 19 3. Positioning the upper rail Page 21 4. Trolley assembly Page 22 5. Power supply unit connection Page 24 6. Installer pushbutton connection Page 24 7.
  • Page 2: System Supply Condition

    7602030 1) SYSTEM SUPPLY CONDITION CAUTION: Disassebmle the bars groups (Fig. 1/c) before inserting the saddles in the guides. The stairlift is supplied subdivided into the following components: Bonnet/Cover unit and inboard pushbutton (Fig. 1/d). Lift structure (Fig. 1/a) CAUTION: Disassemble the upper and rear bonnets Complete with gear motor, drive components with safety (Fig.
  • Page 3: Positioning The Lower Rail

    7602030 FIG.5 2) INSTALLING THE LOWER RAIL - Using the proper assembly punching (Fig. 3/b), locate the first guide section in which is the curve (Fig. 3/a) starting from the high plan. NOTE: If there are no curves, locate the first rectilinear section (Fig.
  • Page 4 7602030 160 mm (Fig. 6/b) clear from the handrail of the separating - Carry out the installation of all guide sections except wall. the last one as formerly described down to the bottom of the scale. - Put the curve connection devices in vertical position (Fig.
  • Page 5: Positioning The Upper Rail

    (Fig. 10/a) must be fixed to the wall. 3) INSTALLING THE UPPER RAIL - Position the spacing gauges (Fig. 11/a) (ask the Vimec service department, as they are not supplied), on the extreme edges of the first positioned guide section (Fig.
  • Page 6: Trolley Assembly

    7602030 FIG.15 4) TROLLEY ASSEMBLY - Position the structure kitted with trolleys in the parking zone at low plan. - Completely fasten the screw M10x30 (Fig. 15/a) with washer (Fig. 15/b) on the friction block in order to re- lease the upper platform balance from the friction group;...
  • Page 7 7602030 FIG.18 - Insert the upper tube (Fig. 18/a) in the swaying trolley (Fig. 18/b) and, with the help of the upper handwheel, (Fig. 18/c), insert it up to execution of the junction with the tube (Fig. 18/d) previously prearranged.
  • Page 8: Power Supply Unit Connection

    (Fig. 21/d). 6) INSTALLER PUSHBUTTON CONNECTION - Connect through suitable connection socket the in- staller pushbutton (Fig. 22/a) (require it to Vimec service department, as it is not supplied). - By means of the (Fig. 22/b - Fig. 22/c) previously de-...
  • Page 9: Connection Feet Final Assembly

    7602030 7) CONNECTION FEET FINAL ASSEMBLY FIG.24 After having done a test operation to make sure that everything has been correctly assembled, it is necessary to fix the support feet to the ground and the connections (where possible) to the wall.
  • Page 10: Bars Assembly

    7602030 FIG.28 8) BARS ASSEMBLY Mount the bars supports (Fig. 29/b) on the machine fra- me (Fig. 29/a) making the corresponding reference pins (Fig. 29/c) match. Tighten the bars with the proper issued screws (Fig. 29/d). Then, proceed to connection of the electrical card sheaths.
  • Page 11: Assembling The Platform With Motorized Access Frontal

    7602030 9) ASSEMBLING THE PLATFORM WITH MOTORIZED f) Connect the lateral guard board operating cables (Fig. ACCESS FRONTAL (B.I. - B.C. - B.R.) 34/f) and frontal (Fig. 34/e) to the fork (Fig. 34/b). On customer request it is possible to have a footboard - Tighten with nut and screw.
  • Page 12 7602030 FIG.33 FIG.34...
  • Page 13 7602030 to the specified position using the register fork (Fig.34/b). Proceeds to check the proper working of the front ac- cess chute: g) Replace the top plate on the platform using the relati- - Check the angle between the chute (in working posi- ve fixing screws.
  • Page 14: Assembling The Platform

    7602030 FIG.39 10) ASSEMBLING THE PLATFORM a) Remove the top plate from the platform by undoing the relative screws. b) Make sure that the two platform supports, fixed by a wedge and a plastic clamp, are in the assembly position (Fig.
  • Page 15: Temporary Assembly Of The Dome For Installation Check

    7602030 11) TEMPORARY ASSEMBLY OF THE DOME - Restore the power supply and press the down button FOR INSTALLATION CHECK until the hook engages. The stairlift will stop when the safety microswitch is pressed by the hook. On completion of the machine mechanism assembly it...
  • Page 16: Rolls For Curve Regulation

    7602030 FIG.44 13) ROLLS FOR CURVE REGULATION On the less sloping curve (Fig. 43/a) place till touching the guide, the rolls for curve (Fig. 43/b). At the end of the regulation tighten the rolls fastening screws (Fig. 43/c) with a 2 daNm couple.
  • Page 17: End Stop Cams And Middle Stop Assembly

    7602030 16) LIMIT STOP CAMS AND INTERMEDIATE STOP - Nel caso di fermata intermedia (Fig. 47/a) assembly ASSEMBLY the support (Fig. 47c) on the tubular (Fig. 47/d) by means of two dowels M8x30 (Fig. 47/e). - Bring the stairlift to the stop position (Fig. 46/a - 47/a Assembly the cam stiffening bracket (Fig.
  • Page 18: Cam Placement And Extrarun Plates Check

    7602030 FIG.49 HIGH 17) CAM PLACEMENT AND EXTRARUN LEVEL PLATES CHECK Before executing the machine final test, it is necessary to check the cams (Fig. 49/a-50/a) and extra-run dishes (Fig. 49/b-50/b) correct placement both on the upper and lower floor.
  • Page 19: Fitting The Casings

    7602030 20) TERMINALS AND PLUG ASSEMBLY 19) FITTING THE BODYWORK SECTIONS (Fig. 53-54) Firmly assembly the dome (Fig. 54/b), removing the support - Mount by pressure the proper issued plugs (56/a) on feet (Fig. 54/a). After having rotated these latter towards each guides connection.