Dear users, thank you very much for purchasing the Pulse Oximeter.
This Manual is written and compiled in accordance with the council directive MDD93/42/EEC for
medical devices and harmonized standards. In case of modifications and software upgrades, the
information contained in this document is subject to change without notice.
The Manual describes, in accordance with the Pulse Oximeter's features and requirements, main
structure, functions, specifications, correct methods for transportation, installation, usage, operation,
repair, maintenance and storage, etc. As well as the safety procedures to protect both the user and
equipment. Refer to the respective chapters for details.
Please read the User Manual carefully before using this product.The User Manual which describes
the operating procedures should be followed strictly. Failure to follow the User Manual may cause
measuring abnormality, equipment damage and human injury. The manufacturer is NOT responsible
for the safety, reliability and performance issues and any monitoring abnormality, human injury and
equipment damage due to users' negligence of the operation instructions. The manufacturer's
warranty service does not cover such faults.
Owing to the forthcoming renovation, the specific products you received may not be totally in
accordance with the description of this User Manual. We would sincerely regret for that.
This product is medical device, which can be used repeatedly.
Internet:
http://www.medipreventiecentrum.nl
(klantenservice)
Instructions to User
MEDIPREVENTIECENTRUM
Bestel in onze webshop. Telefoon:
E-mail:
info@medipreventiecentrum.nl
074-2911110
(klantenservice)
E-mail:
info@medipreventiecentrum.nl
Bestel in onze webshop
I

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pulse Oximeter and is the answer not in the manual?

Questions and answers

Summary of Contents for MEDIPREVENTIECENTRUM Pulse Oximeter

  • Page 1 In case of modifications and software upgrades, the information contained in this document is subject to change without notice. The Manual describes, in accordance with the Pulse Oximeter’s features and requirements, main structure, functions, specifications, correct methods for transportation, installation, usage, operation, repair, maintenance and storage, etc.
  • Page 2 WARNING: Discomfort or pain may appear if using the device ceaselessly, especially for the microcirculation barrier patients. It is recommended that the pulse oximeter should not be used on the same finger for more than 2 hours. For the special patients, there should be a more prudent inspecting in the placing process.
  • Page 3: Table Of Contents

    7.3 Transportation and Storage ...................... 7 8 Troubleshooting ..........................8 9 Key of Symbols ..........................8 10 Function Specification ......................10 Appendix 1 ............................11 Appendix 2 ............................13 MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110 (klantenservice) Internet: http://www.medipreventiecentrum.nl E-mail:...
  • Page 4: Safety

    ֠ When it is carried from cold environment to warm or humid environment, please do not use it immediately. ֠ DO NOT operate button on front panel with sharp things. MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110 (klantenservice) Internet: http://www.medipreventiecentrum.nl E-mail: info@medipreventiecentrum.nl...
  • Page 5: Overview

    The Pulse Oximeter is small in volume,low in power consumption,convenient in operation and portable.It is only necessary for patient to put one finger into probe for diagnosis, and the display screen will directly show the SpO value with the high veracity and repetition.
  • Page 6: Major Applications And Scope Of Application

    2.2 Major Applications and Scope of Application The Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is fit for family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports and it is not recommended to use the device during the process of having sport) and etc.
  • Page 7: Main Parameters

    F Power supply requirement: 3.6 V DC~4.2V DC. G. Optical Sensor Red light (wavelength is 660nm, 6.65mW) Infrared (wavelength is 880nm, 6.75mW) 5 Installation 5.1 View of the Front Panel Figure 2 Front view MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110 (klantenservice) Internet: http://www.medipreventiecentrum.nl E-mail:...
  • Page 8: Battery Installation

    Long press the button to turn the device on, and the measure interface appears after the device self-test. Do not shake the finger and try to keep the patient still during the process. The data can be read directly from the display screen in the measuring interface. MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110 (klantenservice) Internet: http://www.medipreventiecentrum.nl...
  • Page 9: Attention For Operation

    D.The oximeter should not be used at a location or limb tied with arterial canal or blood pressure cuff or receiving intravenous injection. E.Ensure nothing, such as a plaster, can impede the light passage., or else it may result in inaccurate MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110...
  • Page 10: Clinical Restrictions

    The device can not be transported mixed with toxic, harmful, corrosive material. B. The packed device should be stored in room with no corrosive gases and good ventilation. Temperature: -40°C~60°C; Relative Humidity: ≤95% MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110...
  • Page 11: Troubleshooting

    9 Key of Symbols Signal Description Warning – See User Manual %SpO The pulse oxygen saturation (%) PRbpm Pulse rate (bpm) Low-power indication The alarm sound indication MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110 (klantenservice) Internet: http://www.medipreventiecentrum.nl E-mail: info@medipreventiecentrum.nl...
  • Page 12 European Representative WEEE (2002/96/EC) This item is compliant with Medical Device Directive 93/42/EEC of June 14, 1993, a directive of the European Economic Community. battery positive electrode battery cathode electrode MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110 (klantenservice) Internet: http://www.medipreventiecentrum.nl E-mail: info@medipreventiecentrum.nl...
  • Page 13: Function Specification

    Battery working life Charge and discharge not less than 300 times. Dimensions and Weight Dimensions 46(L) × 40(W) × 29(H) mm Weight About 35g (with a buttony lithium battery) MEDIPREVENTIECENTRUM Bestel in onze webshop. Telefoon: 074-2911110 (klantenservice) Internet: http://www.medipreventiecentrum.nl E-mail:...
  • Page 14: Appendix 1

    Guidance and manufacture’s declaration – electromagnetic immunity The CMS50QA Pulse Oximeter is intended for use in the electromagnetic environment specified below. The customer or the user of CMS50QA Pulse Oximeter should assure that it is used in such an environment.
  • Page 15 Guidance and manufacturer’s declaration – electromagnetic immunity – for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacturer’s declaration – electromagnetic immunity Pulse Oximeter The CMS50QA is intended for use in the electromagnetic environment specified below. The customer or the user of...
  • Page 16: Appendix 2

    RF communications equipment and the EQUIPMENT or SYSTEM – for EQUIPMENT or SYSTEM that are not LIFE-SUPPORTING Recommended separation distances between portable and mobile RF communications equipment and the CMS50QA PULSE OXIMETER Pulse Oximeter The CMS50QA is intended for use in an electromagnetic environment in which radiated RF Pulse Oximeter disturbances are controlled.