Ci+ Key Download Method; Local Dimming Function Check - LG 42LV3500 Service Manual

Hide thumbs Also See for 42LV3500:
Table of Contents

Advertisement

* Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or service man, Sometimes
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
1) Press the 'instart' key of ADJ remote controller.
2) Go to the menu '5.Model Number D/L' like below photo.
3) Input the Factory model name(ex 42LD450-ZA) or Serial
number like photo.
4) Check the model name Instart menu -> Factory name
displayed. (ex 42LD450-ZA)
5) Check the Diagnostics (DTV country only) -> Buyer model
displayed. (ex 42LD450)

6. CI+ Key Download method

(1) Download Procedure
1) Press "Power on" key of a service remote control.
(Baud rate : 115200 bps)
2) Connect RS232-C Signal Cable.
3) Write CI+ Key through RS-232-C.
4) Check whether the key was downloaded or not at 'In
Start' menu. (Refer to below).
Copyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
=> Check the Download to CI+ Key value in LGset.
1. check the method of CI+ Key value
a. check the method on Instart menu
b. check the method of RS232C Command
1) into the main ass'y mode (RS232 : aa 00 00)
CMD 1
A
2) check the key download for transmitted command
(RS232 : ci 00 10)
CMD 1
C
3) result value
- normally status for download : OKx
- abnormally status for download : NGx
2. Check the method of CI+ Key value (RS232)
1) into the main ass'y mode (RS232 : aa 00 00)
CMD 1
A
2) Check the method of CI+ key by command (RS232 :
ci 00 20)
CMD 1
C
3) Result value
i 01 OK 1d1852d21c1ed5dcx

7. Local Dimming Function Check

Step 1) Turn on TV.
Step 2) Press "P-only" key, entrance to power only mode and
Press "Exit" key.
Step 3) Press "Tilt" key, entrance to Local Dimming mode.
Step 4) At the Local Dimming mode, module Edge Backlight
moving right to left Back light of module moving.
Step 5) Confirm the Local Dimming mode.
Step 6) Press "Exit" key
- 14 -
CMD 2
Data 0
A
0
0
CMD 2
Data 0
I
1
0
CMD 2
Data 0
A
0
0
CMD 2
Data 0
I
2
0
CI+ key Value
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents