Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. • Installation must be performed by a qualified installer, service agency or the gas supplier. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
MAUI ZERO CLEARANCE General Description Installation Notes & Safety Required Components Assembly Instructions Optional Fresh Air Supply Gas Supply Line Installation of Maui Framing Placement And Finishing Venting Wiring Clearance Shell Diagram 16 Diagram 17 & 18 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Page 3
Logaire Gas Stove Wiring Diagram 22 Checking Thermopile Pilot Instructions When the Pilot wont stay Lit Adjust of the Piolet Flame Robertshaw Valve Check – Millivolt Saftey Magnet Checking Gas Pressure with a Monometer WARRANTY QUALITY ASSURANCE WARRANTY FORM P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Logaire’s warranty program, be sure to fill out the registration form included in the packet and drop it in the mail today! Please take a moment now to acquaint yourself with these instructions and the many features of your Logaire Maui gas stove. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
CAUTION: Hot while in operation. DO NOT TOUCH. Due to high surface temperatures keep children, clothing and furniture away. Keep burner and control compartment clean. See installation and operation instructions accompanying appliance. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Push in the gas control knob slightly and turn clockwise to “OFF”. DO NOT FORCE. Turn off electric power to the appliance if service is to be performed. Do not remove instruction plate: Logaire Maui F/S & I/B P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
240V, .45 A, 50 Hz NOT FOR USE WITH SOLID FUEL. DO NOT REMOVE LABEL. METAL FAB INDUSTRIES; P O BOX 58 473 GREENMOUNT, AUCKLAND FAX (09) 274 8472 Email: sales@metalfab.co.nz SERIAL NUMBER MG NO. _____________________ P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
When off for more than a month, extinguish pilot by following shutdown procedure. (For ON-OFF rocker switch location see page 10). 9. Keep area near the appliance clear and free from combustible materials, gasoline and other flammable vapours and liquids. DIAGRAM 1 DIAGRAM 2 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
2. To turn off pilot light, push in the gas control knob slightly and turn clockwise to “OFF”. Do not force. 3. Turn off all electrical power to the appliance if service is to be performed. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
SPECIFICATIONS LISTINGS AND CODE APPROVALS The Maui Gas Heater has been tested to ANSI Z21.88a-1998 Vented Gas Fireplace Heaters by OMNI – Test Laboratories, Inc. and listed for installation and operations as described in these Installation and Operation Instructions. This gas appliance has been tested in accordance with National Safety standards and complies with the following.
This may be the floor, or it can be raised up on a platform to enhance its visual impact. The Logaire Freestanding Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. The Maui Gas Fire must be seismic restrained through the holes provided.
238mm Minimum ceiling height from top of units is 600mm HEARTH SIZE The Logaire Maui needs to be installed on a non-combustible surface no smaller than the minimum size of the freestander overall dimensions as per Diagram 4. DIAGRAM 4...
Insert Top to Top Facing: 250mm Insert Top to Mantle: 550mm Insert Side to Sidewall: 150mm Insert Side to Side Facing: 75mm Hearth Extension Side: Hearth Extension Front: Hearth Height 300mm 263mm 50mm 225mm 100mm 188mm 150mm DIAGRAM 5 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
6 below. NOTE: Do no remove or alter any part of a factory built fireplace except glass doors or a smoke shelf which can be reinstalled if the Logaire gas insert is removed. DIAGRAM 6 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
FREESTANDER The Maui Freestander must be installed with a B-vent flue system as approved for use by Logaire. For cosmetic or aesthetic purposes a 150mm outer flue can be used as long as an approved inner vent is installed. Fasten the B-vent to the exhaust collar on the top of the stove.
45% with a minimum run of 600 mm height of vertical flue before gradient, provided a 1.5 meter vertical run is fitted after any off-set, Refer to diagram 7. DIAGRAM 7 Any deviation from minimum and maximum recommended dimensions may effect performance of the fire. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
The F/S and I/B gas stoves are available to burn either Natural gas of LPG. The burners are specifically manufactured to burn either one. Make sure the stove you have purchased is equipped for the proper gas. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Refer to diagram 9. WARNING Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. DIAGRAM 9 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
A qualified gas service technician should perform this adjustment. NOTE: ANY SOOTING OR CARBON DAMAGE RESULTING FROM AN INPROPERLY SET PRIMARY AIR SHUTTER IS NOT COVERED UNDER WARRANTY. DIAGRAM 10 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
The heat actuated safety switch will automatically reset after the stove has reduced in temperature. The switch will continue to cycle until the draft problem is corrected. DIAGRAM 11 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
If necessary, seek expert advice. For wind turbulent sites, a wind cap may be necessary to remedy the problem. Draft Relief Openings must not be covered or blocked. DIAGRAM 12 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
This gas heater is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Page 25
INSTALLATION DIAGRAM 13 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Spread the ember chunks around the ends and in front of the log to create a realistic look. You should use the entire bag of embers to accomplish this look. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
The BGV and BGI gas stoves are available to burn either natural gas or propane. The burners are specifically manufactured to burn either one. Make sure the stove that you have purchased is equipped for the proper gas. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
1.61 1.61 1.61 1.51 1.51 1.51 Note: If altitude is more than 500’ above listing on chart use orifice specified at next higher altitude. Example: 7250 ft use a 3.26 7650 ft use a 3.04 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Replace rear panel and test for gas leaks. NOTE: The pilot flame mixture will require to be adjusted. Remove adjustment cover screw – light pilot and adjust flame with adjustments screw until desired flame is acquired. When satisfied replace cover screw. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
After assembly the zero clearance shell may be framed into combustible construction and exhaust venting can be installed using standard B-vent. The Maui gas stove may be installed later. The base of the zero clearance shell may be installed directly on any flat solid continuous flooring material.
8. Align the two side support clips (K) with mounting slot on side panels, and start the screws to hold in place, but do not completely tighten. The flanges on the support clips must be towards the front of the zero clearance shell. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
INSTALLATION OF MAUI 1. Insert the Maui into the zero clearance shell. 2. Slide the 100mm piece of B-vent pipe down into the exhaust collar of the Maui. Fasten both ends of the flex pipe with clamps. 3. To finish installation, please refer to your Maui Vented Gas Stove Installation And Operating Instructions.
1. The framing enclosure must meet the minimum distance to combustibles and existing walls 2. Framing materials may be installed on or against the stand offs on the Maui zero clearance shell. For ease of installation, Maui recommends a minimum framed...
No higher than 100mm above the base, install as electrical bow and outlet in the lower right hand corner. Wire the outlet for 240 volts. The power cord for the Maui will be plugged in here. NOTE: Specifications given in this manual are indicative only.
Page 36
MAUI ZERO CLEARANCE DIAGRAM 16 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Page 37
MAUI ZERO CLEARANCE DIAGRAM 17 DIAGRAM 18 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Page 38
MAUI ZERO CLEARANCE DIAGRAM 19 DIAGRAM 20 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
OUTER HEAT SHIELD (crimpled ends towards the heater) and into the heater flue outlet. Fit FLUE SPACER BRACKETS to FLUE if necessary to maintain air gap between FLUE PIPES and OUTER HEAT SHIELD. DIAGRAM 21 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Page 40
FLUE SPACER BRACKET. NOTE: It is the responsibility of the installer to ensure that the installation of this flue kit complies with the appliance manufacturers specifications for flues and that relevant Local Body requirements are adhered to. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
The position of these logs must be as shown in the diagram under Log Installation. NOTE: Improper positioning of logs may cause carbon build-up and will alter the unit’s performance, which is not covered under warranty. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
To remove the fan, remove the 2 – M6 bolts holding the fan to the unit. NOTE: For the maintenance or replacement of the fan unit, call a qualified service technician P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
If continuity is present, maintain connection with disconnected lead and proceed to the next connection in line. Do this until you find no continuity. This locates the bad connection or defective part. DIAGRAM 22 LOGAIRE GAS STOVE WIRING DIAGRAM 22 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Make sure the thermopile is engulfed in the pilot flame. If the thermopile does not register at least 325 millivolts, the thermopile is defective and needs to be replaced (See diagram 23 ). DIAGRAM 23 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Check the gap at the electrode tip to the canopy (1/8” approx.) – adjust if needed. Inspect ceramic around electrode for cracks. If cracks are present igniter will not work and needs to be replaced (pilot assembly.) DIAGRAM 24 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
If the pilot flame cannot be adjusted there may not be sufficient gas reaching the stove. If so, the inlet pressure will need to be checked. The local gas supplier is responsible for adequate gas volume and should be contacted. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Place red lead of multimeter on TP TH terminal, but not on the connector screw. The reading should be 9 – 11 OHMS + - 10%, if not the valve is defective and must be replaced. DIAGRAM 27 P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
If incoming pressure is sufficient, the only way to correct it on an adjustable flame control valve (Robertshaw) is to replace the regulator on the control valve. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
WARRANTY Logaire Fires warrants to the original consumer purchaser that the Maui stove in its original installation is free from defects in material and workmanship from the original date of purchase as follows. Non-electrical components are covered for three years. Electrical components and valves are covered for one year.
Date of purchase ……………………………………………………………. Serial Number…………………………………………………………………. Dealer purchased from ……………………………………………………… ……………………………………………………………………………………. Installed by …………………………………………………………………….. Date of installation …………………………………………………………… Metal Fab Industries Ltd reserves the right to change specifications or design of its product without prior notice. P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...
Page 52
------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------- PLACE STAMP HERE SEND TO: Metal Fab Industries P O Box 58 473 GREENMOUNT AUCKLAND Public/manufacturing/engineering+fires/fires/Logaire/maui/gasfires P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf...