Download Print this page

Novax 2020-S Installation Handbook page 2

Taxi computer

Advertisement

Fitting Instructions.
Before attempting to install the meter. Get the position right! Hold
it in the car and find the best possible position. It is light enough
to mount above the mirror, on the mirror or glass mount as well
as conventional dash mount, but keep the following in mind:
1. The meter must be clearly visible to all passengers. LCD
displays can be difficult to read if the viewing angle is too great.
2. Mount the meter where it is not likely to be damaged by
passengers or their luggage. Also keep it away from ashtrays.
3. It must be close enough to be operated from the driver's seat.
4. The sealing screw must be readily accessible.
5. Routing of the required wiring.
Once the position is known, if necessary, remove the meter
module from the back-shell case and put it aside. The case can
be fastened in place by small flat head screws using the existing
holes, or it can be held in place with suitable adhesive products.
The meter module is secured to the case only by the sealing
screw and collar.
Connections
For most installations the single 8 way loom supplied is adequate
to allow connections to be made in the engine compartment or
under the dashboard. The loom is colour coded as per diagram
overleaf.
Should the installation require connections to data plugs, GPS
swipe-reader etc. then additional cables may be required (remove
the meter module from the case to plug these in).
Ideally, power and ground connections should be taken directly
from the vehicle's battery terminals.
Note:
1
Although the meter is protected by internal overload
devices, the lamp circuit should be protected by an external
fuse (orange wire) at the battery connection (3 Amp). Where
regulations allow, meter power (brown wire) should also be
taken through a fuse. It's a good idea to ensure these fuses
are removed until all connections have been made, to avoid
damage in the event of accidental shorting of the wires.
2
The lamp drive circuits are controlled by conventional +12v
switching, switching +12v power to the light(s). These are
however solid-state switches and can be easily damaged by
overload conditions. If the aux outputs have other purposes
than tariff lights ensure the circuit is not likely to exceed 3
amps, or if it is required to switch other vehicle circuits, it is
recommended that external relays (with spike suppression
diodes) be used in order to protect the meter circuit board
from damage.
3
Where a receipt printer is to be used, Lamp o/p #3 should
be configured as "Hired" lamp drive, ie selected for all
operating tariffs. This is connected internally to power the
receipt printer. An optional loom is available with an inline
printer connector should this be considered easier.
Once all required connections are made the meter module can be
fitted into the case and the main connector plugged in (note this
is polarised such that it has a correct and an incorrect way round.
Don't force the connector in,! You could have it back to front!
Testing.
For the sake of these instructions the four Operate buttons are re-
ferred to as button 'A', 'B', 'C', and 'D'.
With the meter screen blank, the meter is said to be "Off".
Switch the meter through it's modes, to check operation is OK.
If the meter is configured for a modem, connection will be verified (or
not) in the For Hire screen by the appropriate symbol, or the banner
"No Modem" as the meter searches for it.
If a receipt printer is connected, it can be tested by printing the
"Running Totals". (button 'D' in the Global Totals Mode).
If a GPS receiver is connected the '+' symbol will show once a "Good
fix" has been established.
With the meter "Speedo signal pulse wire" connected to the vehicle's
speedo system it should be possible to verify that distance pulses are
being received by the meter when the vehicle is traveling. This is done
in the "Calibration Mode" and requires the use of a special purpose
device called an "Installation key" to unlock the calibration mode.
To prevent unauthorised alterations to the calibration figure, this func-
tion can ONLY be accessed if the Installation key is in place, this MUST
be fitted to the 4-pin connector under the sealing collar. Ensure you
get it the correct way round with the arrow pointing to the right.
Calibration and
Configuration.
Press button 'D' for the
Data screen then
button 'A', "Menu".
Provided a valid
"Installation key" is in
place the meter will
respond by displaying
"Calibration screen" rather than display the menu.
First, use the function to count the speedo pulses over a measured
distance, (eg a measured kilometre).
To count Speedo pulses hit the button 'B', (Start), this resets the "New
count" to zero, every pulse received from the speedo system will now
be counted and displayed. Drive the vehicle for a short distance in
order to confirm correct operation and satisfactory pick-up of speedo
pulses. Note that alternate pushes of the button 'B' freeze, and restart
the counting of pulses. Now drive over the measured kilometre,
starting the count at the beginning and freezing the count as you cross
the 1,000 metre mark (or 1mile for imperial) on the road.
With the exact calibration displayed, hit the button 'D' (save) in order
to store this number in memory. "Cal. Saved" briefly appears on the
display, as the meter switches Off.
Before storing the new calibration figure it is possible to make fine
adjustments if required, using buttons 'A' and 'C' to increment and
decrement the displayed figure.
Check operation, remove the key, then replace the sealing screw and
collar, make sure that the holes in the screw will allow the wire seal to
pass neatly across the sealing tab.
The Calibration Registration number is advanced each time the meter
is recalibrated.
Confirm the correct number is saved by viewing it in the "Data Mode".
Setup Options.
The Data screen provides information about the meter:
Model, Serial Number, Cab Number, GST number, Date of Manu-
facture and firmware revision. Two sets of registers relating to the
data security provide indelible counters and date stamps which
record each time the meter is programmed with either Fare Sched-
ule or Calibration adjustments.
From the "Data"
screen, access can
be gained to a
"Menu" (button 'A' in
"Data mode") which
allows selection of
various parameters
as shown.
Each entry is PIN pro-
tected with individual PIN numbers. The required parameter can
be selected from the numeric keypad, the four-digit PIN entered.
Clock Adjust.
To access the clock adjust mode; Hit button '1' on the numeric
keypad. This is covered in the Operator's Handbook.
The same editing procedure applies to all parameters.
Should you need to change the PIN number for any entry, this can
be done by hitting button 'D' once you have reached the edit mode
for that particular parameter. This will allow a new four digit PIN to
be entered and saved. Like all PIN numbers, if you forget what you
have set, you're bugg***d!
Shift Period and Lease Period.
These parameters relate to Daily activation periods (Shift) and
Global activation period (Lease). If a driver is to be restricted to say
a twelve hour period each day then the start and end times for the
"shift" can be entered here. During the inactive period he will not
be able to ply For Hire, and the meter is effectively locked.
The Lease Period provides a means to disable the meter should,
for example, the driver be leasing the cab (or the equipment) and
he fail to pay at the required time. The owner (or leaser) can set
the start and end time and date so that the meter will lock at ex-
piry.
Registration Number.
This provides a means to enter the vehicle identification number,
as may be required in some countries, for inclusion on printed re-
ceipts
Setup: Cab number, GST.
This provides a means to enter the cab number and the compa-
nies GST number. Follow the same procedures for all settings,
some provide two parameters under the one selection.
Configuration.
Roughly; consists of 3 sets of two digits:
First digit pair: Options and connections.
Second pair: Interface protocol and port vectors.
Third digit pair: Number of decimal places, Baud rates, GPS vector.

Advertisement

loading