Del ozone delclean CD-7GL-30 Installation & Operation Manual

Clean laundry systems

Advertisement

TM
TM
CD-7GL-30, CD-7GV-11
INSTALLATION & OPERATIONS MANUAL
DEL OZONE · SAN LUIS OBISPO, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
4-1513-01 Rev. C

Advertisement

Table of Contents
loading

Summary of Contents for Del ozone delclean CD-7GL-30

  • Page 1 CD-7GL-30, CD-7GV-11 INSTALLATION & OPERATIONS MANUAL DEL OZONE · SAN LUIS OBISPO, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459 4-1513-01 Rev. C...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION 1 SECTION 4 General Information Replacement Parts & Order Info 1A. Description ............1 4A. Ordering Information ..........4 1B. Specifi cations ............1 4B. Standard Replacement Parts List ......4 Warranty ..............5 SECTION 2 Operation Appendix 2A. Initial System Start-Up .........1 Appendix A: Venturi Installation Instructions ....6 2B.
  • Page 3: General Information

    4. Check for leaks. performance. 5. (CD-7GL-30 only) With the ozone isolation valve closed, adjust injector bypass valve to fl ow water The DEL Clean™ Ozone Laundry System is safe through the injector.
  • Page 4: System Electromechanical Overview

    4. Oxygen Concentrator: Supplies concentrated, dry, oxygen feed gas to the ozone generator. as required. 5. Lo Limit Vacuum Switch (CD-7GL-30 only): If 4. Visual inspection of all plumbing, mechanical, and the vacuum in the ozone output supply line falls wiring in system.
  • Page 5: Troubleshooting

    fl ow meter indicates 0 scfh fl ow. 2. G.F.C.I. has tripped.* 1. Injector not set properly (CD-7GL-30 only). a. Check power cord and reset G.F.C.I. a. Adjust injector bypass valve until proper air fl ow is indicated (~7 scfh).
  • Page 6: Contact Information

    DEL Clean Ozone Laundry Systems Installation & Operations Manual 3D. Contact Information: For Technical assistance: Call: (800) 676-1335 x213 E-mail: service@delozone.com Or visit or web site: www.delozonelaundry.com SECTION 4 Replacement Parts and Order Information 4A. Ordering information: For replacement parts call DEL at 1-800-676-1335 x213 Be prepared with the following information: -Customer Name -Customer Address...
  • Page 7: Warranty

    After this information is provided, DEL Ozone may release a RETURN GOODS AUTHORIZATION (RGA) NUMBER. After receiving the RGA number the part in question must be returned to DEL Ozone, freight prepaid, with the RGA number clearly marked on the outside of the package. All preauthorized defective parts must be returned to DEL Ozone within thirty (30) days.
  • Page 8: Appendix A: Venturi Installation Instructions

    DEL Clean Ozone Laundry Systems Installation & Operations Manual APPENDIX “A” VENTURI INSTALLATION INSTRUCTIONS - CD-7GL-30...
  • Page 9 DEL Clean Ozone Laundry Systems Installation & Operations Manual A1.1.1.2. Refer to Figure 5. Mark the A1. Location locations for the four mounting bolts and The Ozone Generator is designed for wall install anchors appropriate for the mounting mounting. See Figure 5. Mount generator in a surface.
  • Page 10 DEL Clean Ozone Laundry Systems Installation & Operations Manual A2. Plumbing MPT-to-compression fi tting (contained in parts Ozone gas is introduced to the incoming cold water bag) onto check valve. Insert one end of ozone line using a venturi injector. Suction developed by tubing into the fi...
  • Page 11: Appendix B: Pressure Installation Instructions

    DEL Clean Ozone Laundry Systems Installation & Operations Manual APPENDIX “B” PRESSURE INSTALLATION INSTRUCTIONS - CD-7G-11...
  • Page 12 DEL Clean Ozone Laundry Systems Installation & Operations Manual B1. Location B2.2. Floor Mounting (optional) The Ozone Generator is designed for wall B2.2.1. The enclosure can be fl oor mounted to mounting. See fi gure 7. Mount generator in a a solid, fl...
  • Page 13 DEL Clean Ozone Laundry Systems Installation & Operations Manual B4. Plumbing B4.2.4. Wrap Tefl on tape around the male Ozone gas is bubbled into the sump of the washer threads of the compression fi tting. Then, through the ozone supply line. screw the compression fi...
  • Page 14 DEL Clean Ozone Laundry Systems Installation & Operations Manual Ozone External Cold Water In Trigger Line Pressure switch Cold Fill Valve Hot Water In Hot Fill Valve CHECK VALVE INSTALLATION Ozone Supply Line Figure 9: Ozone Installation Line Drawing - Pressure WARNING: The ozone gas supply line must have a back fl...
  • Page 15 DEL Clean Ozone Laundry Systems Installation & Operations Manual B5. Ozone External Trigger Line B6. Ozone gas destruct B5.1. Locate the pressure line inside the washer/ B6.1. Using a length of EPDM rubber hose, connect extractor electrical area. See Figure 10 (left top) the vent destruct to the 3”...
  • Page 16: Appendix C: Safety

    DEL Clean Ozone Laundry Systems Installation & Operations Manual APPENDIX “C” SAFETY...
  • Page 17 DEL Clean Ozone Laundry Systems Installation & Operations Manual HEALTH HAZARDS OF OZONE FIRST AID Detection Levels General Ozone can be detected in air by its distinctive odor at First Action concentrations of about 0.02 ppm. Although each nose 1. If exposure to ozone causes headache or shortness varies, olfactory fatigue occurs quickly.
  • Page 18 (fluid in lungs) as well as affecting the eyes, blood, and central nervous system. Manufacturer/Supplier: On-site generation, equipment available from various suppliers, including: DEL Ozone Phone: (805) 541-1601 3580 Sueldo Street FAX:...
  • Page 19 DEL Clean Ozone Laundry Systems Installation & Operations Manual SECTION VI: HEALTH HAZARD DATA Carcinogenicity: Ozone is not listed as a carcinogen by the NTP, IARC, or OSHA. Primary Entry: Inhalation Target Organs: Respiratory system, eyes, blood. Summary of Risks: There is no true threshold limit and so no exposure (regardless of how small) is theoretically without effect from ozone’s strong oxidative ability.