STO M-8 Operation And Maintenance Instructions

Spray pump

Advertisement

Quick Links

Operation and Maintenance Instructions
Sto M-8 Spray Pump
For assistance, please call:
StoMachine Technology HelpLine
(888) 522-0184
www.stocorp.com
Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331
Phone (404) 346-3666 Fax (404) 346-3119

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M-8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STO M-8

  • Page 1 Operation and Maintenance Instructions Sto M-8 Spray Pump For assistance, please call: StoMachine Technology HelpLine (888) 522-0184 www.stocorp.com Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119...
  • Page 2: Table Of Contents

    9. Technical Data...................... 15 10. Worn Parts......................15 10.1 Membranes....................15 10.2 Conveying Disc..................... 15 10.3 O-Rings ......................15 ________________________________________________________________________________________________________________________ Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119 Page 2 of 15...
  • Page 3: Performance

    Sto M-8 Spray Pump Operation and Maintenance Instructions Performance The Sto M-8 Spray Pump is a new type of pump technology, protected with three different patents. This new technology enables a wide range of Sto products that are capable of being used for spray or roller applications.
  • Page 4: Advantages

    Light and handy (approx. 57 lbs) Operates with 110 V Quiet Perfect spray appearance Proven and tested for every construction site!! ________________________________________________________________________________________________________________________ Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119 Page 4 of 15...
  • Page 5: Use

    Sto M-8 Spray Pump Operation and Maintenance Instructions 1. Use The Sto M-8 Spray Pump conveys liquids, aggregated materials up to 2mm, sand finishes, coatings, concrete, and repair products. When using products for the first time, we recommend applying on a small test area. We do not recommend the use of R (rilled) finishes to be spray applied.
  • Page 6: Operation Of Control Panel

    Sto M-8 Spray Pump Operation and Maintenance Instructions 3.1 Operating the Control Panel “OFF“ – M-8 is switched off 3.2 Forward “FWD“ -- M-8 is switched on (Forward) to pump material through hose. 3.3 Backward “REV“ – M-8 runs backwards. Necessary to clean pump or when blockage occurs in material hose.
  • Page 7: Overload Protection

    To manually or remotely operate the M-8 for running or cleaning, either the remote cable or the dummy plug needs to be connected. _______________________________________________________________________________________________________________ _________ Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119 Page 7 of 15...
  • Page 8: Remote Control Use

    13 on scale = highest pressure. The amount of pressure determines the flow of material. _______________________________________________________________________________________________________________ _________ Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119 Page 8 of 15...
  • Page 9: Operation Of Pump

    Not available in the US. Contact StoMachine Technology HelpLine at (888) 522-0184 for more information. _______________________________________________________________________________________________________________ _________ Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119 Page 9 of 15...
  • Page 10 Note: To operate pump the dummy plug or the remote cable must be connected. If M-8 is not pumping material turn pressure switch to next setting, moving only one setting at a time, until desired material flow is achieved. Important: Do not stress pump and hoses. Please use only as much pressure as needed.
  • Page 11: Clean-Up Of Pump

    Repeat until water is clear. ________________________________________________________________________________________________________________________ Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119 Page 11 of 15...
  • Page 12: How To Change Delivery Washer And Membranes

    Install new parts in reverse order Note: Ensure that the fingers are lubricated between the two rubber diaphragms. ________________________________________________________________________________________________________________________ Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119 Page 12 of 15...
  • Page 13: Trouble Shooting

    Sto M-8 Spray Pump Operation and Maintenance Instructions 7. Trouble Shooting M-8 does not pump: Possible cause: Cap nut that secures flange is not tightened enough. There should be no gap between flange and housing. Pressure switch to select pressure is adjusted too low.
  • Page 14: Technical Recommendation

    Sto M-8 Spray Pump Operation and Maintenance Instructions 8. Technical Recommendation 8.1 Service Manual Check rubber diaphragm and delivery washer for damage and cracks after daily cleaning routine. Exchange rubber diaphragm and delivery washer as described, if necessary. Please check all electrical plugs and power supply before starting.
  • Page 15: Technical Data

    Article No. M900820 - Delivery Washer 1 piece 10.3 O-Rings Article No. M900805 - O-Rings 1 piece _______________________________________________________________________________________________________________ _________ Sto Corp. 3800 Camp Creek Parkway, Bldg 1400, Ste 120 Atlanta, GA 30331 Phone (404) 346-3666 Fax (404) 346-3119 Page 15 of 15...