AQUASTREAM ABSC02787 Installation, Operation & Maintenance Manual

Advertisement

Quick Links

Residential Steambath Generator Systems
Installation,
Operation &
Maintenance
Manual
aquabrass.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ABSC02787 and is the answer not in the manual?

Questions and answers

Summary of Contents for AQUASTREAM ABSC02787

  • Page 1 Residential Steambath Generator Systems Installation, Operation & Maintenance Manual aquabrass.com...
  • Page 2: Table Of Contents

    Residential Steambath Generator Systems Table of contents Aquasteam S elect Your Model ....2 B efore Installing ......3 S team R oom Guidelines .
  • Page 3 Residential Steambath Generator Systems ______________________________ MODEL NO ______________________________ SERIAL NO MODELS ABSC02787 7.5 KW 240V 1ph generator _____________________________________ ABSC02789 9 KW 240V 1ph generator _____________________________________ ABSC02782 12 KW 240V 1ph generator _____________________________________ important note: As you follow WARNING these instructions, you will notice warning and caution symbols.
  • Page 4: S Elect Your Aquasteam Model

    Note: To convert cubic feet ot cubic meters, divide cubic feet by 35.3. E xample: Total cubic feet required is 155. Divide by 35.3 to obtain 4.39 m3. S elect model ABSC02787 aquabrass.com...
  • Page 5: Before Installing

    Residential Steambath Generator Systems Before Installing The following general information should be used in conjunction with consultations with your IMPORTANT: architect, designer and contractor in determining all factors necessary in providing a suitable and safe steam room. R ead these instructions before installation or service. Although this steambath generator has been qualified for shipment, the following must be reviewed for proper, safe and enjoyable steam bathing.
  • Page 6: Locating The S Team Generator Unit

    Re s i de n t i a l St e a m ba t h Ge n e r a t or Sy s t e m s L oc a t i n g t h e St e a m Ge n e r a t or U n i t Select a location as near as practical and outside the steam room.
  • Page 7: Installation

    Residential Steambath Generator Systems Installation Plumbing All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes. Use unions on all pipe connections. Use only brass piping or copper tubing as permitted by codes. Do not use black, galvanized or PVC pipe.
  • Page 8: Generator Dimensions

    P rovide clearance around steam generator as required for service I M P O R T A N T N O T E : and maintenance. DO N OT rough in plumbing and electrical services based on dimensional information provided. Drawing not to scale. ABSC02787 ABSC02782 ABSC02789 ____...
  • Page 9: Electrical Specifications

    ABSC02789 360 (10.19) 240/1 8 (10) __________________________________________________________________________ ABSC02782 575 (16.82) 240/1 6 (16) _________________________________________________________________________ Wiring Diagrams Diagram POWER INPUT for ABSC02787 L E G E N D All Diagrams) TRANSFORMER ABSC02789 FIELD BLACK WHITE WIRING DARK FACTORY BLACK BLUE WIRING...
  • Page 10: Field Power Wiring

    Residential Steambath Generator Systems Models ABSC02787, ABSC02789 (single phase wiring shown) Contactor L, N Ground to be field wired caution Knock-out (fitting omitted TO AVOID E QUIPME NT DAMAGE for clarity) DO NOT CONNE CT POWE R SUPPLY Ground DIR E CTLY TO HE ATING E LE ME NTS !!!
  • Page 11: Optional Automatic Drain System

    Residential Steambath Generator Systems Optional Automatic Drain System (2) Pin Connector BOX CONTENTS: for Automatic Drain Automatic Drain Valve with Cord Installation instructions. Operation The optional Automatic Drain feature Automatic Drain Cord Connector automatically drains the Aquasteam Automatic Drain Cord system following each use.
  • Page 12: Installing The R Emote Temperature Probe

    Residential Steambath Generator Systems Installing the Aquasteam In-Shower Temperature Probe aqua s tea m caution The R emote Temperature Probe is for use with in-shower controls. Controls only. Do not use any other controls. Do not use any other temperature probe aquasteam with the in-shower controls.
  • Page 13 Residential Steambath Generator Systems 5. R oute the end of the temperature probe cable with the temperature probe through the wall into the steam room as shown in Diagram 3. Do not strain, staple, pinch or IMPORTANT NOTE: otherwise damage the probe cable. 6.
  • Page 14: Installing The Aquasteam In-S Hower Control

    Residential Steambath Generator Systems " Step 1 Installating the In-Shower Control 67 mm 1 " 1 " Turn power to the steam generator OFF before IMPORTANT: 25 mm 25 mm installing the control. Failure to turn the power offwill result in an inoperable control.
  • Page 15 Residential Steambath Generator Systems Connection of Aquasteam Control & TemperatureSensor Temp Probe Main Control Valve should be closed when Note: automatic drain is not installed aquabrass.com...
  • Page 16: Operation Of In-S Hower Control

    Residential Steambath Generator Systems Operation of the In-Shower Control On/Off Key ON/OFF K ey is used to turn the steam generator on/off. Press On/Offkey to turn steam generator on. Press a second time to turn steam generator off. A built-in timer automatically shuts the steam generator offa predetermined period of time after it has been started, unless the user does so manually.
  • Page 17: R Eplacement Parts Diagram & List

    Drain Line Replacement Parts List _____________________________________ ITEM PART NUMBER _____________________________________ Liquid Level Probe ABSP02797 _____________________________________ Heating E lement ABSC02787 (7.5KW) ABSP02772 ABSC02789 (9KW) ABSP02773 ABSC02782 (12KW) ABSP02774 _____________________________________ Liquid Level Circuit B oard ABSP02796 _____________________________________ Transformer ABSP02779...
  • Page 18: Warranty

    warranty Residential Steambath Limited Lifetime Warranty THIS WARRANTY DOES NOT APPLY TO AQUASTEAM PROD- aquasteam extends to the original consumer purchaser of a UCTS WHICH ARE USED FOR ANY NON-RESIDENTIAL OR aquasteam. RESIDENTIAL STEAMBATH GENERATOR COMMERCIAL PURPOSE. THE FOREGOING IS IN LIEU OF ALL (aquasteam Generator), installed in the United States or EXPRESS OR IMPLIED WARRANTIES AND AQUASTEAM DOES Canada (excluding controls and accessories), a warranty that...
  • Page 20 residential steambath generators and control by aquabrass aquabrass.com...

This manual is also suitable for:

Absc02789Absc02782