Residential Steambath Generator Systems Table of contents Aquasteam S elect Your Model ....2 B efore Installing ......3 S team R oom Guidelines .
Page 3
Residential Steambath Generator Systems ______________________________ MODEL NO ______________________________ SERIAL NO MODELS ABSC02787 7.5 KW 240V 1ph generator _____________________________________ ABSC02789 9 KW 240V 1ph generator _____________________________________ ABSC02782 12 KW 240V 1ph generator _____________________________________ important note: As you follow WARNING these instructions, you will notice warning and caution symbols.
Note: To convert cubic feet ot cubic meters, divide cubic feet by 35.3. E xample: Total cubic feet required is 155. Divide by 35.3 to obtain 4.39 m3. S elect model ABSC02787 aquabrass.com...
Residential Steambath Generator Systems Before Installing The following general information should be used in conjunction with consultations with your IMPORTANT: architect, designer and contractor in determining all factors necessary in providing a suitable and safe steam room. R ead these instructions before installation or service. Although this steambath generator has been qualified for shipment, the following must be reviewed for proper, safe and enjoyable steam bathing.
Re s i de n t i a l St e a m ba t h Ge n e r a t or Sy s t e m s L oc a t i n g t h e St e a m Ge n e r a t or U n i t Select a location as near as practical and outside the steam room.
Residential Steambath Generator Systems Installation Plumbing All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes. Use unions on all pipe connections. Use only brass piping or copper tubing as permitted by codes. Do not use black, galvanized or PVC pipe.
P rovide clearance around steam generator as required for service I M P O R T A N T N O T E : and maintenance. DO N OT rough in plumbing and electrical services based on dimensional information provided. Drawing not to scale. ABSC02787 ABSC02782 ABSC02789 ____...
ABSC02789 360 (10.19) 240/1 8 (10) __________________________________________________________________________ ABSC02782 575 (16.82) 240/1 6 (16) _________________________________________________________________________ Wiring Diagrams Diagram POWER INPUT for ABSC02787 L E G E N D All Diagrams) TRANSFORMER ABSC02789 FIELD BLACK WHITE WIRING DARK FACTORY BLACK BLUE WIRING...
Residential Steambath Generator Systems Models ABSC02787, ABSC02789 (single phase wiring shown) Contactor L, N Ground to be field wired caution Knock-out (fitting omitted TO AVOID E QUIPME NT DAMAGE for clarity) DO NOT CONNE CT POWE R SUPPLY Ground DIR E CTLY TO HE ATING E LE ME NTS !!!
Residential Steambath Generator Systems Optional Automatic Drain System (2) Pin Connector BOX CONTENTS: for Automatic Drain Automatic Drain Valve with Cord Installation instructions. Operation The optional Automatic Drain feature Automatic Drain Cord Connector automatically drains the Aquasteam Automatic Drain Cord system following each use.
Residential Steambath Generator Systems Installing the Aquasteam In-Shower Temperature Probe aqua s tea m caution The R emote Temperature Probe is for use with in-shower controls. Controls only. Do not use any other controls. Do not use any other temperature probe aquasteam with the in-shower controls.
Page 13
Residential Steambath Generator Systems 5. R oute the end of the temperature probe cable with the temperature probe through the wall into the steam room as shown in Diagram 3. Do not strain, staple, pinch or IMPORTANT NOTE: otherwise damage the probe cable. 6.
Residential Steambath Generator Systems " Step 1 Installating the In-Shower Control 67 mm 1 " 1 " Turn power to the steam generator OFF before IMPORTANT: 25 mm 25 mm installing the control. Failure to turn the power offwill result in an inoperable control.
Page 15
Residential Steambath Generator Systems Connection of Aquasteam Control & TemperatureSensor Temp Probe Main Control Valve should be closed when Note: automatic drain is not installed aquabrass.com...
Residential Steambath Generator Systems Operation of the In-Shower Control On/Off Key ON/OFF K ey is used to turn the steam generator on/off. Press On/Offkey to turn steam generator on. Press a second time to turn steam generator off. A built-in timer automatically shuts the steam generator offa predetermined period of time after it has been started, unless the user does so manually.
warranty Residential Steambath Limited Lifetime Warranty THIS WARRANTY DOES NOT APPLY TO AQUASTEAM PROD- aquasteam extends to the original consumer purchaser of a UCTS WHICH ARE USED FOR ANY NON-RESIDENTIAL OR aquasteam. RESIDENTIAL STEAMBATH GENERATOR COMMERCIAL PURPOSE. THE FOREGOING IS IN LIEU OF ALL (aquasteam Generator), installed in the United States or EXPRESS OR IMPLIED WARRANTIES AND AQUASTEAM DOES Canada (excluding controls and accessories), a warranty that...