DEMINERALIZZATORE D’ACQUA Manuale Operatore WATER DEMINERALIZER User Manual DEMINERALISATEUR D’EAU Manuel d’utilisation UMKEHROSMOSEANLAGE Bedienerhandbuch DESMINERALIZADOR DE AGUA Manual Operador...
D#0MDAA1000X 05-2008 New hydraulic and electrical drawing New installation and maintenance procedures 97050402 05-2011 Address and code updating on Mocom use and maintenance manuals 97050402 07-2011 Correcting the board setting indication TABLE OF CONTENTS INTRODUCTION ................................1 APPLICABLE EUROPEAN DIRECTIVES ....................... 1 INTENDED USE ..............................
Page 6
Case 3: Connection to an electric-type drawing tap (option) ................13 FIRST STARTUP ................................14 MILLDROP CONNECTED TO THE STERILIZER SERIES MILLENNIUM ............14 MILLDROP CONNECTED TO THE FEEDING TANK .................... 14 MILLDROP CONNECTED TO THE MANUAL DRAWING TAP ................15 STAND-BY STATUS ..............................
INTRODUCTION INTRODUCTION Dear Client Thank you for choosing this product from M.O.COM. Srl. We hope that you will find it completely satisfactory. This manual describes all procedures for the correct installation and use of the equipment. Should you have any questions or suggestions concerning this product or our support, do not hesitate to contact us.
INTRODUCTION The purpose of this manual is to provide directions for: PURPOSE OF THE MANUAL - becoming familiar with the product; - its appropriate installation; - its secure and efficient employment. The appendixes provide information regarding: - technical characteristics; - maintenance procedures; - analysis and solution of problems;...
Feeding pipe (blue), complete with gaskets – Ref. 4; • Reinforced silicone pipe (Ref. 5) for connecting Milldrop to sterilizer, external tank or tap; • Power supply cable – Ref. • Kit (Ref. 7) containing: start/stop signal cable, nr. 2 pipes union, nr.
The equipment operation is controlled by an electronic board which also monitors any alarm (leak and lack of water, quality of the output water, etc.). “Milldrop” may be installed on a work plane, hung to a wall or set inside the washbasin piece of furniture.
L - Purging tube quick connector FUNCTIONING The Milldrop operation is very easy and automatic in any use. Directly connected to a Millennium series sterilizer, it operates at the start of the sterilizer’s water feeding pump, and until the pump stops.
INSTALLATION The correct and careful installation is the first and fundamental step in achieving the good INSTALLATION demineralizer operation, long life and complete utilization of its features. INTRODUCTION Moreover, this precaution will avoid the danger for physical injury or property damage, not to mention equipment malfunctions and faults.
Install the unit so that any external fill/drain piping is not bent or crushed. The length of the reinforced silicone tube connecting Milldrop to the sterilizer or tank, shall not exceed 2 meters, otherwise performance quality could fall or, what is worse, the demineralizer itself could not operate properly.
Remove the screws (1) and the lid (A). Figure A Remove the screws (2-3) and the side panel (B). Figure A Position the panel (B) on the wall where Milldrop has to be installed and mark the wall by a pencil in the mounting slots (C). Figure B...
CONNECTIONS 1. Use the kit supplied (Page 3, Ref. 2) and install the draining bracket onto the washbasin’s siphon where you wish to install the Milldrop draining pipe; carry out an Initial installation hole Ø 6 mm in the siphon across the bracket’s fitting.
Page 16
4. Plug the key (supplied with the kit - page 3, Ref. 7) in the fitting of the purging tap positioned under the Milldrop equipment and turn the tap on "Service Mode" position. 5. Plug the purging jack (supplied with the kit - Page 3, Ref. 7) in the connector "T".
INSTALLATION Case 1: See Figure G: Direct connection to a Keep the DIP1 position on the electronic board unchanged (see diagram on page 25): sterilizer series Make sure that the position is as indicated in the Millenium figure. If not, correct it. DIP1 1.
(optional) figure. If not, correct it. DIP1 Plug the supplied pipe fitting in the inlet point (label “Milldrop”) of the tank. Cut the silicone pipe (connected to the quick connector “C” on the demineralizer rear panel) long enough to reach the pipe-union installed on the tank’s inlet (label “Milldrop”), fit and tight by clamps.
INSTALLATION Case 3: See Figure I: Connection to an Configure DIP1 on the Milldrop electronic board as follows (see diagram on page 25): electric-type drawing Remove the external cover and the protection of the tap (option) electronic board. Change the setting of the DIP1 switches as shown in the figure Refit the covers.
FIRST STARTUP Once properly installed, proceed with the following additional startup operations and FIRST STARTUP checks according with the Milldrop use. MILLDROP Turn on the demineralizer and then the sterilizer. CONNECTED TO THE STERILIZER Ended the initial test of the sterilizer, enter the SETUP menu, select “Filling Options” and the mode “AUTOMATIC”...
FIRST STARTUP Press the tap’s button to start the water delivery. MILLDROP CONNECTED TO Press 2 seconds again the tap’s button to stop the water delivery. THE MANUAL DRAWING TAP NOTA ’ SECONDS BEFORE PRESSING AGAIN THE TAP S BUTTON TO RESTART...
APPENDIX A – TECHNICAL DATA APPENDIX A – TECHNICAL CHARACTERISTICS SUMMARY TABLE Device REVERSE OSMOSIS WATER DEMINERALIZER Model Milldrop C.M.F. S.r.l. Via E.Ellero, 9 33080 Cusano di Zoppola (PN [=Province of Pordenone]) - ITALY Manufacturer M.O.COM. Srl Via Saliceto, 22...
APPENDIX A – TECHNICAL DATA CHARACTERISTICS OF THE DEMINERALISED WATER FILTERING CHARACTERISTICS The following table shows the demineralizer’s average filtering characteristics, compared with values stated by the standards EN 285 and EN 13060. Value according Unit of Value at the Value at the Element/Characteristic measure...
APPENDIX B – MAINTENANCE APPENDIX B - MAINTENANCE In addition to the procedures for the correct use, it needs the user performs an ordinary INTRODUCTION maintenance in order to guarantee safe and efficient operation over the entire life of the equipment.
FILTERS See Figures L and M: Resin filter cartridges Turn off Milldrop, remove the mains cable and disconnect pipes and cable from the use side (sterilizer, feeding tank or drawing tap). Turn off the water tap feeding the Milldrop. Remove the screws (1) and take off the lid (A).
Replace first the osmotic membrane. See Figure N Turn off Milldrop, remove the mains cable and the hydraulic and electric connection with the equipment (sterilizer, tank or drawing tap). Proceed as for the resin filter cartridges, and remove the whole filter assembly (A) from its supports to access the osmotic membrane assembly (B).
Page 27
(not supplied) and place the opposite end inside a wash-basin. verify that the jack of the start/stop cable coming from the sterilizer, tank or drawing tap is disconnected from the Milldrop; plug the purging jack in the “T” connector.
FLOW RESTRICTOR Turn off Milldrop and remove the mains cable. Turn off the water tap feeding the Milldrop, remove the equipment lid and the side panel. Disconnect the “flow restrictor” from the red pipes Ø6 and replace with a new one.
This fault condition is preceded by an intermediate phase during which Milldrop, even if correctly operating, turns on the yellow LED (matched with the acoustic alarm) to signal that the filter replacement is coming near.
Page 30
APPENDIX C – TROUBLESHOOTING PROBLEM POSSIBLE CAUSE PROPOSED SOLUTION Entry tap closed. Open the tap. Water work pressure insufficient. Check the water pressure. Alarm: Solenoid valve filter clogged up Clean the filter (see rear view, page 5). lack of water (red Pressure switch failure.
APPENDIX D - DIAGRAMS APPENDIX D - DIAGRAMS ELECTRIC DIAGRAM Probe terminal board Configuration dip-switch Ground Temperature Water leak sensor Pressure switch –NC contact Start/Stop signal (tank/tap) Sonda Probe Start/Stop signal (sterilizer) Electric valve Pump Transformer 230 Vac...
M.O.COM. Srl is completely available to customers to provide any technical information about the product as well as to offer suggestions and advice on steam sterilization procedures. In this regard, please refer to the following address: M.O.COM. Srl Via Saliceto, 22 40013 Castel Maggiore (BO) Italy website www.mocom.it...