  • Page 1 ® Dialogic BorderNet™ 4000 Session Border Controller (SBC) Installation and Deployment Guide December 2013 64-1191-03 www.dialogic.com...
  • Page 2 Borough of Saint-Laurent, Montreal, Quebec, Canada H4T 2B5. Any authorized use of Dialogic's trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic’s trademarks requires proper acknowledgement.
  • Page 3: Revision History

    Dialogic Corporation or its subsidiaries. The listed hardware warranty periods and terms are subject to change without notice. For purchases not made directly from Dialogic please contact your direct vendor in connection with the warranty period and terms that they offer.
  • Page 4: Table Of Contents

    Table of Contents Revision History ..................... 3 Hardware Limited Warranty ................... 3 Introduction ....................5 Configuration ....................6 Physical Description and Specifications............7 BorderNet 4000 SBC dimensions ................ 7 Detailed Dimensions ..................8 Power Specifications ..................8 Typical Specifications ..................9 Environmental Specifications ................
  • Page 5: Introduction

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide Introduction The Dialogic® BorderNet™ 4000 Session Border Controller (also referred to herein as the BorderNet 4000 SBC and/or BorderNet 4000) is shipped with the following components: • Power cords: AC units - Country-specific power cord specified per order.
  • Page 6: Configuration

    Configuration The BorderNet 4000 SBC is available in the following configurations: Product number Description BN4-BSH-1000 BorderNet 4000 SBC HA base hardware, DC power supplies, four (4) 4m DC power cables, AQR1U Rack Mount Kit, Copper NICs and base system software BN4-BSH-1001 BorderNet 4000 SBC HA base hardware, AC power supplies, AQR1U Rack Mount Kit, Copper NICs and base...
  • Page 7: Physical Description And Specifications

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide Physical Description and Specifications The following table provides approximate weights for the BorderNet 4000 SBC: Component Approximate equipment Approximate packaging weight weight BorderNet 4000 SBC with: 26.8 lbs (12.16 kg) 5.9 lbs (2.7 kg) •...
  • Page 8: Detailed Dimensions

    Detailed Dimensions The following illustrations provide detailed dimensions of the BorderNet 4000 SBC: Power Specifications The following table lists the BorderNet 4000 SBC absolute maximum power specifications: Power supply Power component Specification Current 10 - 5 A Voltage 100 - 240 V AC Frequency 50-60 Hz Voltage...
  • Page 9: Typical Specifications

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide Typical Specifications The following numbers are representative only. Actual power consumption depends on environmental conditions and deployment use case. Scenario Power Specification Worst case @ 50 Degrees C 420 Watts – 2xCPU Running Intel Maximum Power...
  • Page 10: Panel Descriptions

    Panel Descriptions Front Panel The following illustration shows the front panel of the BorderNet 4000 SBC (with the front bezel removed): Status panel The status panel consists of LEDs, panel switches and a USB connector. The status LEDs change from green to red when a fault is triggered. The P Fault LED is off unless a fault is triggered.
  • Page 11: Rear Panel

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide Component Description Indicates hard drive activity. This LED blinks when a disk drive is reading or being written to and does not change color. When there is no hard drive activity, this LED is off.
  • Page 12: Ethernet Interfaces

    Ethernet Interfaces The following illustration shows the interface numbering and LED assignments for a BorderNet 4000 SBC. The BorderNet 4000 SBC includes the following interfaces: Interface Description Eth0, Eth1, Eth2, Eth3 10/100/1000 Base-T Ethernet interfaces Eth4, Eth5, Eth6, Eth7, Eth8, Eth9, 10/100/1000 Base-T Ethernet interfaces or Eth10, Eth11 optical SFP interfaces.
  • Page 13: Safety Precautions

    • Maintenance: There are no user-serviceable parts inside the BorderNet 4000 SBC. Only technically qualified personnel approved by Dialogic should perform service and maintenance tasks. • Avoid injury: Lifting the BorderNet 4000 SBC and attaching it to the rack is a two- person job.
  • Page 14 CAUTION: Boards with fiber interfaces contain Class 1 laser devices. Class 1 lasers are not considered to be hazardous. All adjustments have been made at the factory prior to shipment of the devices. No maintenance or alteration to the device is required. Do not tamper with or modify the performance of the device.
  • Page 15: Installing The Rack Mount Kit

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide Installing the Rack Mount Kit When mounting the BorderNet 4000 SBC, follow these requirements: • Elevated operating ambient: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient.
  • Page 16: Four-Post Rack With Square Holes

    The following illustration shows the slide rail assembly: Four-Post Rack with Square Holes If the four-post rack at your site has square holes, refer to the instructions included in the box with the Tool-Less Blade Slide Kit. Four-Post Rack with Round Holes If the four-post rack at your site has round holes, complete the following procedure to use the post adapter and screw kit to convert the square holes to round holes: 1.
  • Page 17 ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide 5. Mount the rail slides to the rack and secure them with two M5 screws at each end. There are a total of 8 screws; you will use two screws at each end of the rails. Torque to 4.5~5.0 kgf-cm (3.9 ~ 4.3 lbf-in).
  • Page 18: Installing The Bordernet 4000 Sbc

    Ethernet configurations including the number of connections and IP addressing are deployment specific. To initially configure the BorderNet 4000 SBC, connect Eth0 and refer to the Dialogic® BorderNet™ 4000 Session BorderNet Controller (SBC) Configuration and Provisioning Guide. 4. To connect to a 10Base-T, 100Base-T, or 1000Base-T network, use shielded twisted pair (STP) Category 5 or better Ethernet cables.
  • Page 19: Dc Power Cables

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide Note: MAC addresses shown in bold are obtained from the compliance label. Label MAC address with offset Ethernet interface M_ENET XX-XX-XX-XX-XX-XX ETH1 motherboard interface XX-XX-XX-XX-XX-XX + 1 ETH2 motherboard interface XX-XX-XX-XX-XX-XX + 2...
  • Page 20: Ac Power Cables

    AC power cables The following table lists the available AC power cables: Part number Description ACC000001 North America Pwr crd, 2.5M, IEC 320 C13/NEMA 5-15P, 15A/125VAC: NA, Asia ACC000002 United Kingdom Pwr crd, 2M, IEC 320 C13/BS 1363, 10A/250VAC: GB ACC000003 Continental Europe Pwr crd, 2M, IEC 320 C13/CEE 7/7, 10A/250VAC: FR, ES, DE...
  • Page 21 ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide • The AC plug end must be terminated in a grounding-type male plug designed for use in your region. The plug ends must be labeled or marked to indicate they have been certified by an agency acceptable in your region.
  • Page 22: Cabling The Bordernet 4000 Sbc

    Cabling the BorderNet 4000 SBC This section shows how to cable the BorderNet SBC 4000 in two configurations: • Standalone • High Availability (HA) Cables In either configuration, the cables can be either of the following: • RJ-45 Ethernet cable – Category 5 (CAT 5) or better. •...
  • Page 23: High Availability (Ha) Configuration

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide High Availability (HA) Configuration The following diagram shows the cabling for an HA configuration. HA links between two platforms of the HA system have to be a direct connection as follows: •...
  • Page 24: Interfaces

    Interfaces The particular configuration of the BorderNet 4000 SBC may vary; therefore, your particular model may not have all of interfaces listed here. RJ-45 Ethernet Interface Pin Assignments RJ-45 Ethernet interfaces use the following pin assignments: MDI = Media Dependent Interface M = Minus P = Plus LC-OLC-DPLX (optical)
  • Page 25: Field Replaceable Units And Accessories

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide Field Replaceable Units and Accessories If a component on your BorderNet 4000 SBC fails, field replaceable components are available for order. The following table lists the field replaceable units (FRUs) and...
  • Page 26: Deploying And Redeploying The Bordernet 4000 Sbc

    10. Deploying and Redeploying the BorderNet 4000 Overview The BorderNet 4000 SBC deployment is the initial setup of the system in a customer network. It can be done at the customer site or done at Dialogic. Deployment includes the following steps: •...
  • Page 27: Deploying The Bordernet 4000 Sbc

    ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide License File The license file is tied to the system and defines the licensed features (for example, HA and H.323.) Virtual MAC In an HA configuration, when Virtual MAC disabled; the new Active platform takes over the ownership of Virtual IP addresses configured on the system.
  • Page 28 Standalone 1. Select Standalone for the Deployment Type. 2. Browse to the License File and select it. 3. Complete the remaining fields below. 4. Click Start Deployment. 5. Once the deployment is complete, the following screen appears.
  • Page 29 Management IP address entered in the deployment process. Note: You must be on the same subnet as that of System Management IP address to access the management interface. Refer to the Dialogic® BorderNet™ 4000 SBC Quick Start Guide for first-time access instructions. HA System 1.
  • Page 30 3. Browse to the License File. 4. Complete the remaining fields below. 5. Click Start Deployment. 6. Once the deployment is complete, the following screen appears.
  • Page 31 Management IP address entered in the deployment process. Note: You must be on the same subnet as that of System Management IP address to access the management interface. Refer to the Dialogic® BorderNet™ 4000 SBC Quick Start Guide for first-time access instructions.
  • Page 32: Redeploying The Bordernet 4000

    Redeploying the BorderNet 4000 Redeploy the BorderNet 4000 SBC when you want to change the basic system configuration such as: • System management IP address • HA link IP address • Utility IP address You need to redeploy the system to convert a standalone to an HA system and vice versa. Guidelines Follow the guidelines below when redeploying a system: •...
  • Page 33 ® Dialogic BorderNet™ 4000 SBC Installation and Deployment Guide...
  • Page 34 2. Click Redeploy to edit the values. The following screen appears: 3. Complete the fields and click Start.