WARNING: If the information in these instructions is not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
This appliance may be installed in an aftermarket permanently located, manufactured
home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases, unless a certified conversion kit is
used.
INSTALLER: After installation, explain the operation and maintenance to the owner and leave this manual.
Installation,
Operation
and
Owner's Manual
Report No. 284-F-06-5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H50-01-NG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Halcyon H50-01-NG

  • Page 1 Installation, Operation H A L C Y O N Owner’s Manual Direct · Vent · Gas · Fireplace WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. —...
  • Page 2: Table Of Contents

    CAUTION This Note symbol indicates a decision or information point Note in the installation process. Unless otherwise noted, the drawings in this Manual are not to scale. Halcyon Gas Fireplace EuropeanHome.com...
  • Page 3: Important Safety Information

    ½ psi (3.5 kPa). 3. The Halcyon Gas Fireplace must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply system at test pressures equal to or less than ½...
  • Page 4: Massachusetts Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Halcyon Gas Fireplace EuropeanHome.com...
  • Page 5: Specifications

    Total Height 44” Bead-to-Bead Height 157/8” Glass Frame Height 145/16” Viewable Height 123/4” Bead-to-Floor 6” Total Width 59” Bead-to-Bead Width 513/4” Glass Frame Width 501/2” Viewable Width 483/4” Cabinet Width (Standoffs) 561/4” Table 1 - Cabinet Dimensions Halcyon Gas Fireplace EuropeanHome.com...
  • Page 6 Rear of Cabinet to Center Line of Vent Collar 71/4” Rear of Cabinet to Center Line of Gas Access 87/16” Bottom of Cabinet to Center Line of Gas Access 33/8” Cabinet Center Line to Left (or Right) Standoff 281/8” Table 2 - Cabinet Dimensions Halcyon Gas Fireplace EuropeanHome.com...
  • Page 7 Fireplace Heaters and CAN/CGA-2.17-M91, Gas-Fired Appliances for Use At High Altitudes standards. The Halcyon Gas Fireplace is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet) in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having jurisdiction for gas product installations to determine their specific requirements for high altitude installations.
  • Page 8 SPECIFICATIONS HALCYON DIRECT VENT GAS FIREPLACE Model: H50 Serial Number: ____________________________________________________________________________________________________________________________________________________________________________________ VENTED GAS FIREPLACE HEATER – NOT FOR USE WITH SOLID FUEL This vented gas replace heater is not for use with air lters. This vented gas replace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory conversion kit must be used.
  • Page 9: Pre-Installation Planning

    Your Halcyon Gas Fireplace will arrive in two packages; the cabinet - including the burner and glass panel assembly - on a pallet, and a carton with everything else. Please inspect your shipment for completeness and any damage. Contact your retailer if any damage is found.
  • Page 10 Figure 6 shows some example installations. Since the Halcyon Gas Fireplace weighs several hundred pounds, it must be placed on a sturdy and level surface. It can be placed on the floor or a raised platform made of wood or non-combustible materials - do not place the Fireplace on carpet or vinyl tile.
  • Page 11 Figure 7 - Rough Opening Table 3, below, lists the minimum dimensions of the rough opening (shown in Figure 7) into which the Halcyon Gas Fireplace is set. It also lists the minimum height of an enclosure (W) and the minimum distance between a room ceiling and the bottom of the Halcyon (V).
  • Page 12 P2. ABOVE THE FIREPLACE Almost all of the heat produced by the Halcyon Gas Fireplace rises directly up the wall into which it is set. This subjects the wall above the Fireplace (and anything attached to the wall) to elevated temperatures. The European Home Remote Heat Kit (included) is designed to keep the wall cooler by moving heat away from the Fireplace.
  • Page 13 Your proposed vent configuration should offer as little resistance as possible to the rising of hot air. Any venting configuration used by the Halcyon must fall within the limits of Chart 1. All measurements are taken from the center of the vent connector on the top of the Halcyon cabinet.
  • Page 14 4 - Degagement conforme aux codes d’installation locaux et aux exigences du fournisseur de gaz. 5 - Permitted ONLY if veranda, porch, deck or balcony is fully open on a minimum of two sides below the floor. Halcyon Gas Fireplace EuropeanHome.com...
  • Page 15: Minimum Clearances To Combustibles

    When the Halcyon Gas Fireplace is to be installed directly on carpeting, vinyl tile or combustible material other than wood floor- ing, it must be installed on a metal or wood panel extending the full width and depth of the Fireplace cabinet.
  • Page 16 Figure 12 - Mantel, Ceiling and Enclosure Clear- ances (right side view) Enclosure 12” 10” Ceiling Line 8” 6” 22” 20½” 4” 19” Top Line of 57½” 17½” Glass 44” Panel Frame 16” Non-combustible Wall Face Glass Panel 21” Halcyon Gas Fireplace EuropeanHome.com...
  • Page 17 • Figure 13 shows the combustible facing limits for the Halcyon Gas Fireplace. Combustible wall facing is not permitted inside this 653/4” x 44” limit. The 44” dimension is measured from the bottom of the cabinet to the top of the standoff panel and the 653/4”...
  • Page 18: Installation

    The relief openings are located behind the left and right access doors mounted on the front of the Halcyon Gas Fireplace. Using the finger hole, slide the door left or right the door as appropriate.
  • Page 19 3. PLACE THE CABINET Since the Halcyon Gas Fireplace weighs several hundred pounds, it must be placed on a sturdy and level surface. It can be placed on the floor or a raised platform made of wood or non-combustible materials - do not place the Fireplace on carpet or vinyl tile.
  • Page 20: Installation - Electrical Assembly

    Thermostat Circuit The Thermostat Circuit is powered by a 24V AC transformer inside of the Halcyon and consists of 25 feet of thermostat wire (wired to the Control Module) and a remote control receiver (included.) Alternatively, the Thermostat Circuit may be wired to a customer- provided 24V thermostat or SPST switch.
  • Page 21 While ensuring that at least ten inches of slack remains within the Wiring Tunnel, run the thermostat wire to the work box and connect it to the receiver. g) With the connections secure, push all slack inside the Wiring Tunnel and attach the Cover Plate. Halcyon Gas Fireplace EuropeanHome.com...
  • Page 22 WHITE 24V AC Receiver (Remote Control) 24V AC BLACK 110V AC Transformer Power WHITE 110V AC BLUE 110V AC Lamp Power PURPLE 110V AC Device Ground GREEN — Table 7 - Wire Colors for External Connections Halcyon Gas Fireplace EuropeanHome.com...
  • Page 23: Installation - Gas Supply

    ½ psi (3.5 kPa). The Halcyon Gas Fireplace must be isolated from the gas supply system by closing the service valve during any pressure testing of the gas Opening for Burner Connection supply system at test pressures equal to or less than 1/2 psi (3.5 kPa).
  • Page 24 See the MAINTENANCE section. Figure 20 shows Stainless Steel panels; other panel types are also available. Figure 20 - Halcyon Panel Numbers 7. INSTALL THE MEDIA The contents of the bag of Burner Media should be spread to an even depth over the entire burner top.
  • Page 25 8. INSTALL THE GLASS PANEL ASSEMBLY Proper care of the glass panel assembly is important for the safe operation of the Halcyon Gas Fireplace. Do not abuse the glass panel assembly by slamming , striking or scratching it.
  • Page 26 INSTALLATION In order to ease the latching/unlatching of the glass panel assembly, the Halcyon Gas Fireplace comes equipped with a standard 5/8” combination wrench. The wrench is used to make it easier to move the latches – your fingers can do the job just as well.
  • Page 27: Installation - Venting

    This section provides venting information which is specific to the Halcyon Gas Fireplace. The Halcyon Gas Fireplace is a direct vent fireplace that uses a co-axial or “pipe within a pipe” venting system. The outer “pipe” or vent (8” diameter) conducts outside air into the Fireplace and the inner vent (5” diameter) carries the exhaust outside. This technology, which can run either horizontally through a side wall or vertically through the roof, produces an efficient system because conditioned building air is not used for combustion.
  • Page 28 • When installed with one foot of rise, the Halcyon can be installed with no more than two 90° elbows OR four 45° elbows OR a combination totaling no more than 180° ‘elbow degrees’ . For example, a combination of one 90° elbow and two 45° elbows is allowed (90°...
  • Page 29 10. ADJUSTING THE DRAFT As the Halcyon Gas Fireplace warms the attached venting, a draft is created. This draft acts on both the intake and exhaust sides of the venting and produces an effect on the Fireplace flames. In order to obtain the performance for which the Halcyon was designed, the air intake and exhaust outlet must be adjusted before the installation is complete.
  • Page 30 In this case, the Air Intake Adjustment Quadrant is set to a position one half of the way between C and D and the Exhaust Outlet Adjustment Quadrant is set to a position one quarter of the way between 3 and 4. 6’ 3’ 8’ Figure 27- Venting Example Halcyon Gas Fireplace EuropeanHome.com...
  • Page 31 Chart is black. Therefore, this configuration is not allowed. 6’ 10’ 3’ Figure 29- Venting Example Example D The example shown in Figure 29, (10’ of rise and 9’ of run) has four 90° elbows and is, therefore, not allowed. Halcyon Gas Fireplace EuropeanHome.com...
  • Page 32 INSTALLATION - VENTING Chart 2 - Air Intake and Exhaust Outlet Restrictor Settings - NATURAL GAS E 31/2 D1/2 31/2 D 31/2 C1/2 31/2 C1/2 31/4 B1/2 21/2 Horizontal Vent Run (in feet) Air Intake Restrictor Setting Exhaust Outlet Restrictor Setting Venting NOT Allowed Halcyon Gas Fireplace EuropeanHome.com...
  • Page 33 INSTALLATION - VENTING Chart 3 - Air Intake and Exhaust Outlet Restrictor Settings - LP GAS E 31/2 D1/2 31/2 D 31/2 C1/2 31/2 C1/2 31/4 C1/2 3 B1/2 21/2 Horizontal Vent Run (in feet) Air Intake Restrictor Setting Exhaust Outlet Restrictor Setting Venting NOT Allowed Halcyon Gas Fireplace EuropeanHome.com...
  • Page 34: Installation - Remote Heat Kit

    • When choosing the duct box finish, do not use a register instead of a grille. If the flow of warm air from the Halcyon Gas Fireplace is blocked the wall above the Glass Panel Assembly will be subjected to elevated temperatures. The grille MUST have a minimum open area of 41%.
  • Page 35 Screw each duct collar to the cabinet. Mount the left and right duct boxes within their respective rough openings. See Figure 31. g) Cut the insulated duct into the appropriate lengths from that supplied in the kit. Halcyon Gas Fireplace EuropeanHome.com...
  • Page 36 12” Secure each end with two sheet metal screws. Figure 31 - Duct Box Rough Opening Dimensions 14” Upper Cover Insulation Disc Lower Cover Port Figure 32 - Exploded View of the Halcyon Remote Heat Port. Halcyon Gas Fireplace EuropeanHome.com...
  • Page 37 OPERATION As the Halcyon Gas Fireplace heats the air within the cabinet it rises up through the insulated ducts and out through the grilles. This heated air is replaced with cooler room air that enters the cabinet from around the Glass Panel Assembly. When the Halcyon cools, the movement of air stops.
  • Page 38: Operating The Fireplace

    How to light your Halcyon Gas Fireplace for the first time is detailed in this section. The first time you light your Halcyon Gas Fireplace an odor may be given off by the unit. This is normal and is a result of the ‘burn off’...
  • Page 39 Set the Flame Switch to OFF to turn o the appliance. CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other liquids having ammable vapors away. EUROPEAN HOME 376 Washington Street Malden, MA 02148 Halcyon Gas Fireplace EuropeanHome.com tel: 781.233-8383 www.europeanhome.com...
  • Page 40: Completing The Installation

    Fireplace which has been operating for at least an hour. The flames on your Halcyon Gas Fireplace should be mostly yellow, about four inches long and have some motion to them. They should be neither short and blue nor long and sooty.
  • Page 41 Once all adjustments are made, tighten both the Air Intake and Exhaust Outlet Quadrant locking wing nuts. Turn the Fireplace off and let it cool to room temperature. Close the access doors the before proceeding with the installation. Halcyon Gas Fireplace EuropeanHome.com...
  • Page 42 • Provided the required clearances are maintained, the walls that enclose the side and rear of the Halcyon Gas Fireplace may be constructed of combustible material. The facing within the limits shown in Figure 13, however, must be made of non-combustible material.
  • Page 43: Maintenance

    Do NOT clean the glass when it is hot! To keep your Halcyon Gas Fireplace in peak condition, routine inspection and maintenance should be performed by a qualified service person. We recommend that this be done prior to the beginning of your heating season.
  • Page 44 PERIODIC CLEANING NOTE: Both sides of the Halcyon glass panel must be cleaned after the first fire. As part of the ‘burn-off’ process, a white film may form on the inside of the glass during the first few fires. Do not allow the film to accumulate as it can become very difficult to remove.
  • Page 45: Troubleshooting

    Any repair and troubleshooting of the Halcyon Gas Fireplace must be done by a qualified technician only. Since the LED on the control module cannot been seen after the Fireplace has been installed, the following assumes that the Halcyon Burner Assembly has been safely connected to a test bench and that all appropriate safety precautions are being observed.
  • Page 46 Check gas supply and pressure to valve. Check sparks and wiring as above. Check limit switches, check sensor leads, check ground continuity, Does the Halcyon run until check pilot flame remains on flame sensor when main burner lights, turned off? check gas jets are clear, check for clean burn.
  • Page 47: Installation Record

    Installer Name:____________________________________________________________________________________________ Installer Phone:____________________________________________________________________________________________ Sold By:__________________________________________________________________________________________________ Fuel: Natural Gas Propane Inlet Pressure at Installation:_________________________________________________________________________________ Manifold Pressure at Installation :_____________________________________________________________________________ Total Vertical Vent Rise:_____________________________________________________________________________________ Total Horizontal Vent Run:___________________________________________________________________________________ Total Number of 90° Elbows:_________________________________________________________________________________ Total Number of 45° Elbows:_________________________________________________________________________________ Halcyon Gas Fireplace EuropeanHome.com...
  • Page 48 NOTES Halcyon Gas Fireplace EuropeanHome.com...
  • Page 49: Appendix A - Lp Gas Conversion

    - an assortment of open end wrenches (3/8” through 1”) • One Burner Base Gasket (H50-FG-BG-03) - a No. 2 Phillips screwdriver • One LP Conversion Label - two adjustable wrenches • One Instruction Sheet - 9/16” socket wrench Halcyon Gas Fireplace EuropeanHome.com...
  • Page 50 Separate the four-conductor plastic connector (the largest of the three connectors) by depressing the latch that holds them together. See Figure A2. Carefully remove the burner assembly from the cabinet and place it on a clean, sturdy work surface. Figure A1 - Halcyon Burner Moved To Right Revealing Connections Latch Figure A2 - Male Connector Showing Latch Halcyon Gas Fireplace EuropeanHome.com...
  • Page 51 10. Loosen the Pilot Burner Nut and push in the Orifice Slide to engage the LP Orifice. The red dot and “LP” marking on the Slide will now be exposed and the “NA” marking will be hidden. Tighten the Pilot Burner Nut securely. See Figure A4. Pilot Burner Nut Orifice Slide Figure A4 - Pilot Burner Details Halcyon Gas Fireplace EuropeanHome.com...
  • Page 52 Installation, Operation and Owner’s Manual and complete the installation. Retain the removed parts if the Halcyon Gas Fireplace is to be re-converted for use with natural gas. Figure A7 - Close-up of Regulator Cap Set to “NAT”...
  • Page 53 Fireplace Heaters and CAN/CGA-2.17-M91, Gas-Fired Appliances for Use At High Altitudes standards. The Halcyon Gas Fireplace is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet) in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having jurisdiction for gas product installations to determine their specific requirements for high altitude installations.
  • Page 54 EUROPEAN HOME a division of Europa Ja, Inc. 376 Washington Street Suite 203 Malden, MA 02148-1300 tel: 781.324.8383 fax: 781.324.8384 info@europeanhome.com Halcyon Gas Fireplace EuropeanHome.com rev.110707u...

This manual is also suitable for:

H50-01-lpH50

Table of Contents