Model 3000 Hybrid Electronic Air Cleaner 90-1293 Safety and Installation Manual Model 3000 Hybrid Electronic Air Cleaner READ AND SAVE THIS MANUAL...
SPECIFICATIONS Description The Model 3000 Hybrid Electronic Air Cleaner is an electronically enhanced “ElectraMedia” air cleaner. Unit Dimensions Overall Unit – See Figure 2, page 3...
Door Retainers Inner Housing Source 1 Model S1-FM501 Media Power Pack/Door Assembly Coated side of media Pleat Spacers (6) 90-1294 FIGURE 2 – Dimensions of the Model 3000 Hybrid Electronic Air Cleaner BOTTOM VIEW ” Outlet ” ” ” ” Inlet ”...
LOCATING THE AIR CLEANER The Model 3000 Hybrid Electronic Air FIGURE 3 – Clearance for Inner Housing Removal Cleaner can be installed in a variety of ways. The figures below show some of the possibilities. It is important to leave enough room to remove The air cleaner may be installed on the and re-install the Inner Housing.
INSTALLING THE OUTER HOUSING AND INNER HOUSING ASSEMBLY WARNING 120 Volts may cause serious injury from electrical shock. Leave power disconnected until installation is complete. 1. Turn the system OFF at the thermostat by changing the mode selector to OFF – FIGURE 10 this may be a switch or a pushbutton, depending on the type of thermostat.
WIRING AND START UP WARNING 120 Volts may cause serious injury from electrical shock. Leave power disconnected until installation is complete. 1. Install a grounded (earth ground) 120-volt single receptacle outlet in accordance with NEC Standards and local codes, into which the EAC will be plugged.
Page 7
FIGURE 12 FIGURE 13 IT IS COMMON TO SEE SPADE LINE TERMINALS ON THE HVAC REFER TO THE VOLTAGE EQUIPMENT CONTROL INSTRUCTIONS PROVIDED CENTER CIRCUIT BOARD . WITH MODEL WIRE USE ONLY FULLY INSULATED S1-HEACRELAY120V FITTINGS (FEMALE QUICK FOR WIRING DETAILS DISCONNECTS SHOWN ).
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE(S) SOLUTION(S) ON/OFF switch not in ON position Turn switch ON Air cleaner not plugged in Plug in air cleaner Light does not come on at all after Insufficient current to activate Wrap blower common wire around relay bracket more - see 90 seconds Model S1-HEACRELAY120V relay Figure 14 on page 7 for wire wrapping method...
FIGURE 16 Bus Bar Ionizer Wires Control Electrode Ionizer Frame Control Electrode Media Ground Inner Housing Contacts Ionizer Frame Control Electrode Ground Contact 90-1151...
• Replace the media no less often than once per year. • Always use Genuine Source 1 Model S1-FM501 Replacement Media. The Model 3000 Hybrid Electronic Air Cleaner is designed to work only with Genuine Source 1 Model S1-FM501 Replacement Media. Use of other media will damage your Model 3000 Hybrid Electronic Air Cleaner.
MAINTENANCE RECOMMENDATIONS (CONTINUED) CLEAN THE IONIZER WIRES Particles will normally build up on the positively charged ionizer wires during operation. The ionizer wires should be cleaned to maintain the highest level of filtration. • Clean the ionizer wires at least once a year. Procedure: 1.
Page 12
Unitary Products Group Form 359520 220455 1.08 5005 York Drive, Norman, OK 73069 10007501 B2700974A...