INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your product. Retain these instructions
for future reference.
The product you have purchased is of the highest quality work-
manship and material, and has been engineered to give you
long and reliable service. This product has been carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your item(s) carefully to ensure that no damage
occurred during shipment. If damage has occurred, please con-
tact the place of purchase. They will assist you in replacement or
repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING
TO
INSTALL,
YOUR PRODUCT. KNOW THE PRODUCT'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
DESCRIPTION
This is a magnetic drive pump intended to move water through
aquarium filtration systems. The pump should be installed external
to the aquarium and filtration systems, and is usually mounted
below the aquarium in the cabinet that houses the filtration sys-
tems. The pump head parts are made of glass filled polypropylene.
The spindle shaft and thrust washers are ceramic. The impeller
driven magnet is coated ceramagnet A (barium ferrite) type ceram-
ic. O-ring seals are nitrile. The motor is thermally protected.
MAGNETIC DRIVE
AQUARIUM PUMP
2-MDQ-SC 2-MDQX-SC
3-MDQ-SC 3-MDQX-SC
4-MDQ-SC 4-MDQX-SC
CAREFULLY
BEFORE
OPERATE,
OR
SERVICE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
Figure 1 • Figure 1 • Figura 1
SAFETY GUIDELINES
DANGER: To avoid possible electric shock, special care
should be taken in the use of aquarium equipment. For each
of the following situations, do not attempt repairs yourself;
return the appliance to an authorized service facility for service
or discard the pump.
1. Do not handle the pump with wet hands or when standing on
a wet or damp surface or in water.
2. If the appliance falls into the water, DO NOT reach for it! First
unplug it and then retrieve it. If electrical components of the
appliance get wet, unplug the appliance immediately. (nonim-
mersible equipment only)
3. Carefully examine the appliance after installation. It should
not be plugged in if there is water on parts not intended to be
wet.
4. Do not operate the pump if it has a damaged cord or plug, or if
it is malfunctioning or if it is dropped or damaged in any manner.
5. To avoid the possibility of the pump plug or receptacle get-
ting wet, position aquarium stand and tank to one side of a
wall-mounted receptacle to prevent water from dripping onto
the receptacle or plug. Arrange a drip loop for each cord con-
necting an aquarium pump to a receptacle (Figure 1). The drip
loop is that part of the cord below the level of the receptacle
(or the connector if an extension cord is used) that prevents
water from traveling along the cord and coming in contact with
the receptacle. If the plug or receptacle does get wet, DO NOT
unplug the cord. Disconnect the fuse or circuit breaker that
supplies power to the pump. Then unplug and examine for
presence of water in the receptacle.
6. Close supervision is necessary when any pump is used by or
near children.
7. Always unplug the pump from the outlet when not in use,
before putting on or taking off parts, and before cleaning. Never
yank cord to pull plug from outlet. Grasp the plug and pull to
disconnect.
8. Do not use the pump for other than intended use.
9. Do not install or store the pump where it will be exposed to the
weather or to temperatures below freezing.
1

Advertisement

Table of Contents
loading

Summary of Contents for Little Giant 2-MDQ-SC

  • Page 1 Franklin Electric Co., Inc. P. O. Box 12010 DANGER: To avoid possible electric shock, special care Oklahoma City, OK 73157-2010 2-MDQ-SC 2-MDQX-SC 405.947.2511 • Fax: 405.947.8720 should be taken in the use of aquarium equipment. For each www.LittleGiantPump.com 3-MDQ-SC 3-MDQX-SC of the following situations, do not attempt repairs yourself;...
  • Page 2: Electrical Connections

    Figure 2. This pump should not be used with a three to two grounding adaptor. 4. If pump is tripping circuit breakers or GFCI, or not operating prop- erly after cleaning, return it to Little Giant or its authorized OPERATION service center. DO NOT attempt repairs yourself.
  • Page 3: Connexions Électriques

    DESCRIPTION inférieur à celui de la pompe afin d’éviter la surchauffe. Placez le cordon à un endroit où personne ne risque de trébucher sur La pompe que vous avez achetée est activée par magnétisme et lui ou de le tirer par inadvertance. est conçue pour produire un courant d’eau dans les systèmes de filtration des aquariums.
  • Page 4: Normas De Seguridad

    à la terre (GFI) ou si elle fonctionne mal après le por el usuario para cada cuerda que conecta una bomba de nettoyage, retourner l’article à Little Giant ou à un centre de acuario a un receptacle. Un “lazo de goteo” (drip loop) debe service autorisé.
  • Page 5: Conexiones Electricas

    (GFCI) o si no funciona apro- de alimentación de corriente que tiene un conductor y un tipo de piadamente después de limpiarla, devuélvala a Little Giant o enchufe con conexión a tierra. Este debe enchufarse en un toma- llévela a un taller autorizado de servicio, NO intente efectuar...
  • Page 6 PART NO. DESCRIPTION ARTICLE PARTIE NO. DESCRIPTION 580506 580507 581506 581903 581507 581517 582506 582507 ARTÍCULO PARTE NO. DESCRIPCION 2-MDQ-SC 2-MDQX-SC 3-MDQ-SC 3-MDQ-SC 3-MDQX-SC 3-MDQX-SC 4-MDQ-SC 4-MDQX-SC 977447 MOTOR, 115V 977459 MOTOR, 115V 977861 MOTOR, 230V 977446 MOTOR, 115V 180037...
  • Page 7: Limited Warranty

    2. Product connected to voltage other than indicated on nameplate dont la tension est supérieure à 15 volts. Little Giant Pump Company offre une assortiment de GFCI et recommande chaque pompe est 3.
  • Page 8 ..... . .1-888-572-9933 Para la ayuda técnica, por favor póngase en contacto ..1-888-956-0000 www.LittleGiantPump.com CustomerService-WTS@fele.com Form 993610 - 10/28/2009 © 2009 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

This manual is also suitable for:

3-mdq-sc4-mdq-sc2-mdqx-sc3-mdqx-sc4-mdqx-sc

Table of Contents