Pails
Solvent and oil/based fluids:
follow local code. Use only
conductive metal pails, placed on
a grounded surface such as
concrete.

Setup

ti5300a
1
Connect Graco airless hose
to sprayer.
Tighten securely.
310820H
ti5850a
Do not place pail on a
nonconductive surface such as
paper or cardboard which
interrupts grounding continuity.
ti2702b
2
Connect other end of hose
to gun.
ti5851a
Grounding a metal pail: connect a
ground wire to the pail by clamping
one end to pail and other end to a
true earth ground such as a water
pipe.
ti2703b
3
Tighten securely.
To maintain grounding
continuity when flushing or
relieving pressure: hold metal
part of spray gun firmly to side
of a grounded metal pail. Then
trigger gun.
ti2769a
4
Remove tip guard.