Living Water  User Manual

Living Water User Manual

Water ionization, filtration, ph optimization for drinking , cooking, cleaning, and other uses

Advertisement

LIVING
WATER
WATER IONIZATION, FILTRATION, pH OPTIMIZATION
FOR DRINKING, COOKING, CLEANING, AND OTHER USES
USER'S MANUAL
CAUTION: Read manual carefully for
proper procedures and operation.
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Living water and is the answer not in the manual?

Questions and answers

Summary of Contents for Living Water Living water

  • Page 1 LIVING WATER ® WATER IONIZATION, FILTRATION, pH OPTIMIZATION FOR DRINKING, COOKING, CLEANING, AND OTHER USES USER’S MANUAL CAUTION: Read manual carefully for proper procedures and operation.
  • Page 2: Important Safety Information

    PLEASE READ THIS MANUAL PRIOR TO INSTALLATION AND OPERATION Important Safety Information • Use only as described in this manual. Use only DO NOT DRINK: manufacturer’s recommended attachments. • Any acidic water • Do not handle plug or appliance with wet hands.
  • Page 3 PLEASE READ THIS MANUAL PRIOR TO INSTALLATION AND OPERATION Disclosures IMPORTANT NOTICE: Failure to install • No medical claims are made by the according to the User’s Manual and in manufacturer or distributor, nor are they accordance with applicable city, state, and responsible for any adverse effects that may local plumbing codes can result in leaks and/or result from the use, or misuse of ionized water.
  • Page 4 LIVING WATER USAGE AND SPECIFICATIONS The Living Water is a water ionizer designed for SPECIFICATIONS use on a counter top or other sturdy surface where Voltage 100 - 40 VAC / 50~60 Hz there is access to a COLD water supply, a drain, and an electrical outlet.
  • Page 5: In The Box

    PACKAGE CONTENTS All parts for a typical installation are included with Carefully unpack your water ionizer, the purchase of your water ionizer. Other parts which making sure all the parts listed on the are not included may be required for your specific diagram are enclosed.
  • Page 6 ANY water ionizer. Tap water provided of well water) generally requires a sediment by municipal water companies typically has a prefilter.Your Vollara Independent Business pH value between 7.1 and 7.3, and a moderate Owner can help you decide if additional water...
  • Page 7 INSTALLATION Faucet Diverter Installation Rubber Washer Adapter Rubber Washer Diverter Valve 1. Remove the aerator from the . Assemble rubber washers, diverter valve adapter, and faucet faucet head (put this in a location diverter as shown. Tighten firmly. The use of pliers may be where you can find it if you ever required to tighten the diverter.
  • Page 8 INSTALLATION Connecting The Drain Line Acidic Water Outlet Port Clamp 3/8” tubing 1. Cut a length of tubing sufficient to reach . Slide a hose clamp over one end of the from your sink to the acidic water output port 3/8”...
  • Page 9: Optional Wall Mounting

    OPTIONAL WALL MOUNTING Wall Mount Installation Using The Wall Bracket 1. Select a suitable wall location to mount the unit. Allow sufficient overhead clearance to hang the unit on the bracket. . The wall bracket may be used as a template to Wall Bracket mark locations for screws and plastic anchors Mounting...
  • Page 10 OPERATION Control Panel LCD Display Filtered Water Function Alkaline Water Func. Filtered Alkaline 10.0 Settings Setting Acidic Alkaline Increase Acidic Alkaline Decrease – SUPER Alkaline Acidic Water Super Setting Settings You can make pH value changes to settings 4.0, settings. The ORP number displayed on the 5.5, 8.5, 9.0, 9.5 and 10.0.
  • Page 11: Lcd Display

    LCD DISPLAy ORP / PH Levels ..Indicates when display is showing ORP level or pH level of output water. Pressing FUNC changes the displayed information. Note: water is not ready for use while Working is flashing.
  • Page 12: Filter Replacement

    FILTER REPLACEMENT You need to change the filters when one of the following occur: NOTE: Water will drain out the • When the LCD display shows 10,000L. bottom of the unit when the old • Every year, even if the display is showing less than 10,000L. filters are pulled out.
  • Page 13: Super Acidic Water/Salt Port

    SUPER ACIDIC WATER / SALT PORT A pH level down to .0+ is possible (super acidic water) using the salt port option. This water is astringent. CAUTION: Super acidic water is for external use only. DO NOT DRINK acidic water from 1.
  • Page 14: Citric Acid Electrode Cleaning

    CITRIC ACID ELECTRODE CLEANING Salt Port Cleaning Adapter Stainless Steel Water Delivery Hose Water Pump Plug (plugged in) Ionizer Plug (not plugged in) 4 0 0 0 Acidic Water Hose 3 5 0 2 5 0 0 2 0 0 0 1 5 0 0 NOTE: The stainless steel 1 0 0 0...
  • Page 15: Ph Testing

    PH TESTING Testing The pH Value Of your Ionized Water 1. Turn on your water ionizer and let it run for about 10 seconds until “Working” is not flashing on the LCD display. 10.0  drops testing liquid 1/ vial ionized water .
  • Page 16: Troubleshooting

    TROUBLESHOOTING Symptom Possible Cause Possible Solution Clogged filter(s) Replace Filter(s) Check tubing for kinked or bent Water source line pinched Water flow has decreased. The restrictions amount of water coming out of Stainless steel water delivery unit getting less and less Straighten or replace the hose hose may be bent Inlet valve (diverter valve) not...
  • Page 17: Frequently Asked Questions

    FREqUENTLy ASKED qUESTIONS Q: What is the white powder that sticks to a cup Q: Why is it unsafe to take medicine with ionized or kettle? water? A: Alkaline-forming minerals, including calcium, A: Because the water makes the medicine more magnesium, sodium, potassium, iron, and absorbable in the body.
  • Page 18 LIMITED 5 yEAR WARRANTy Customer should not repackage and ship the Living Water® unit due to possibility of irreparable damage. For warranty service, please contact your Independent Business Owner for the address of the nearest service center, or call Customer Service at 800.989.2299.
  • Page 19 For the latest information, please visit our web site. FCC DECLARATION OF CONFORMITY Name: Vollara, LLC Model: Living Water This equipment has been tested and found to comply with the limits for a Class B digital device pursuit to Part 15 of the FCC Rules.
  • Page 20 *P65-00368* 65-00368-EA-0373 Vollara, LLC | 540 LBJ Freeway | Suite 1010 | Dallas, TX 7540 | 800.989.99 © Vollara, LLC. All Rights Reserved...