Focal Point MUSE P23 Installation Instructions Manual

Wall mounted flueless gas fire

Advertisement

Quick Links

MUSE
MODEL : P23
WALL MOUNTED FLUELESS GAS FIRE

INSTALLATION INSTRUCTIONS

It is the LAW that all gas appliances and fittings are installed by a competent person (such as a CORGI registered fitter) and in
accordance with the Gas Safety (Installation and Use) Regulations 1998.
All instructions must be handed to the user for safekeeping.
Revision A - 05/07
Country(s) of destination - GB/IE
Focal Point Fires plc, Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e-mail: sales@focalpointfires.co.uk
©
2007 Focal Point Fires plc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUSE P23 and is the answer not in the manual?

Questions and answers

Summary of Contents for Focal Point MUSE P23

  • Page 1: Installation Instructions

    Gas Safety (Installation and Use) Regulations 1998. All instructions must be handed to the user for safekeeping. Revision A - 05/07 Country(s) of destination - GB/IE Focal Point Fires plc, Christchurch, Dorset BH23 2BT Tel: 01202 499330 Fax: 01202 499326 www.focalpointfires.co.uk e-mail: sales@focalpointfires.co.uk...
  • Page 2: Table Of Contents

    Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet is owned by Focal Point Fires plc.You are not permitted to copy or adapt any of the content without the prior written per- mission of Focal Point Fires plc.
  • Page 3: Appliance Data

    It is recommended that the appliance should not be installed within 1 metre of any air vent. © 2007 Focal Point Fires plc.
  • Page 4: Ventilation

    An openable window or equivalent is also required. The require- ments of other flued appliance operating in the same room or space must be taken into consideration when assess- ing ventilation. © 2007 Focal Point Fires plc.
  • Page 5: Unpacking The Appliance

    Joints should be kept to a minimum and compression fittings must not be used. The pipework installation must be tested for tightness before any protection is applied and/or the pipework and fit- tings are buried. © 2007 Focal Point Fires plc.
  • Page 6: Fixing The Appliance

    If it is necessary to clean or dust off the burner then the glass door should be removed by removal of the four retaining screws. Re-fit the glass door after cleaning or inspection, ensuring the correct orientation and a good seal. © 2007 Focal Point Fires plc.
  • Page 7: Testing And Commisioning

    In the event that the burner pressure is not in accordance with the figures stated in the data section of these instruc- tions, the appliance must not be commissioned, and the manufacturer should be contacted for guidance. © 2007 Focal Point Fires plc.
  • Page 8: Fitting The Decorative Frame

    12. Refit the decorative facia/frame assembly as detailed in section 8.4. 13. Check the purpose provided ventilation is un-obstructed. 14. Light the fire and test setting pressures. 15. Check safe operation of the appliance. For specific servicing instructions, see relevant sections. © 2007 Focal Point Fires plc.
  • Page 9: Servicing The Burner Unit

    To convert from parts per million (ppm) to a percentage (%) divide the ppm figure by 10,000. Examples : 35ppm = 0.0035%, 15ppm = 0.0015%, 5ppm = 0.0005%. © 2007 Focal Point Fires plc.
  • Page 10: Testing For Firebox Leakage

    Combustible materials used in incorrect positions. DO005895/0 As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to © amend details and/or specifications without prior notice. 2007 Focal Point Fires plc.
  • Page 11: User Instructions

    All instructions must be handed to the user for safekeeping. Revision A - 05/07 Country(s) of destination - GB/IE Next Retail Ltd, Desford Road, Enderby, Leicester LE19 4AT Helpline Telephone : 0844 844 8999 © 2007 Focal Point Fires plc.
  • Page 12 Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet is owned by Focal Point Fires plc.You are not permitted to copy or adapt any of the content without the prior written per- mission of Focal Point Fires plc.
  • Page 13: Clearances To Combustibles

    A supply of fresh air into the room is advisable to maintain temperatures within limits. The appliance MUST NOT be installed in a bedroom or bathroom. For Republic of Ireland, see relevant rules in force. © 2007 Focal Point Fires plc.
  • Page 14: Operating Instructions

    Burner tray FB/780081 Catalyst IN/F940136 Seal kit for Catalyst Manufactured by: Focal Point Fires plc, Christchurch, Dorset BH23 2BT Tel: 01202 499330 Fax: 01202 499326 www.focalpointfires.co.uk e-mail: sales@focalpointfires.co.uk DO005900/0 As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice.

Table of Contents