USP AD-2000 Owner's Manual

USP AD-2000 Owner's Manual

Automatic voice/pager dialer system with verification

Advertisement

M O D E L A D - 2 0 0 0
A u t o m a t i c V o i c e / P a g e r
D i a l e r S y s t e m
w i t h V e r i f i c a t i o n
N o t j u s t t h e n e x t g e n e r a t i o n ... i t ' s t h e n e x t m i l l e n n i u m !
Versatile * Full-featured * Easy to Program
2-way Listen in Verification
Operates with all alarm systems
Ideal stand-alone dialer
Provides reliable emergency notification 24 hours a day

Advertisement

Table of Contents
loading

Summary of Contents for USP AD-2000

  • Page 1 M O D E L A D - 2 0 0 0 A u t o m a t i c V o i c e / P a g e r D i a l e r S y s t e m w i t h V e r i f i c a t i o n N o t j u s t t h e n e x t g e n e r a t i o n …...
  • Page 2: How It Works

    For The Next Millennium Congratulations! Thank you for purchasing United Security Products, Inc.’s Model AD-2000 - the “smartest”, most comprehensive automatic voice/pager security dialer available. Representing an exciting new level of achievement, the AD-2000 combines technologically advanced features, ease of programming and reliable operation in a compact, unobtrusive dialer completely compatible with any security alarm system.
  • Page 3: Table Of Contents

    THIS PACKAGE CONTAINS: 1 ea. MODEL AD-2000 1 ea. PHONE CABLE 1 ea. INSTRUCTION MANUAL 4 ea. 1K RESISTORS T A B L E O F C O N T E N T S Section Page number Package contents………………………………………………………………… Panel Displays……………………………………………………………………...
  • Page 4: Panel Displays

    P A N E L D I S P L A Y S...
  • Page 5: Installation Hookups: Alarm Panel

    A D - 2 0 0 0 I N S T A L L A T I O N H O O K U P S Alarm Panel...
  • Page 6: Installation Hookups: Stand Alone

    A D - 2 0 0 0 I N S T A L L A T I O N H O O K U P S Stand Alone...
  • Page 7: Programming The Dialer

    P R O G R A M M I N G T H E D I A L E R Overview Please study this section thoroughly before beginning to program the dialer, referring to the Sample Program Planner on page 13. Then, select from among the options for each feature, listing each choice in pencil on the blank Program Planner on page 14.
  • Page 8: Programming Phone/Pager Numbers

    P R O G R A M M I N G T H E D I A L E R First Time Installation to Initialize Dialer Follow Steps 1 & 2. STEP 1 Apply power to the unit. STEP 2 Press 1.
  • Page 9: Programming Auxiliary Information

    Structuring Your Outgoing Messages LINE), PBX, Dialing Attempts and Message Repeat options. If The AD-2000 dialer was designed with optimum versatility and you choose to accept the following default prompts, simply functionality in mind. Nowhere is this more apparent than in the press “2”...
  • Page 10: Programming/Recording Ogms

    P R O G R A M M I N G T H E D I A L E R Programming And Recording Your Programming The Channels The AD-2000 is designed to be adaptable to a complete range of Outgoing Messages personalized applications. Each of the four input channels can be Follow these steps to program and record your outgoing programmed individually for full system customization.
  • Page 11: Testing Your System

    P R O G R A M M I N G T H E D I A L E R Normally Open/Normally Closed B) Continue the above procedure for each of the up to eight phone/pager numbers programmed in. STEP 6 The LCD will read: STEP 9 The LCD will read:...
  • Page 12: Operating Your System

    You are now ready to begin operating your system, Under a momentary activation, a single violation of a relying on the AD-2000 to work in conjunction with your channel will cause the dialer to initiate delivering all pre- alarm system to provide 24-hour security reassurance and selected OGMs to all programmed numbers associated with peace of mind.
  • Page 13: Programming Example

    Sample Program Planner specific outgoing messages (OGMs). Programming Example for Quick Setup STEP 7 Before programming the dialer, study the example shown on this page. Using a prepared script and speakin g six-to-eight inches This “quick setup” example programs in one telephone number, two from the dialer’s microphone on the front of the unit, press “R”...
  • Page 14: Blank Program Planner

    Fill out this Program Planner in pencil initially After thoroughly testing your system, redo your Program Planner in ink. One copy should be kept in a safe place by the end user; one copy should be retained by the installer.
  • Page 15: Specifications

    RTS: Adjustable Temperature Controller, N.O., N.C. Wireless Upgrade: PLS: Power Loss Sensor (110VAC) The standard AD-2000 can be upgraded for wireless link-up with RF-activated mag contacts, motion sensors, pendant, etc., by Sensors installing a new back cover containing a pre-tested RF assembly Magnetic Contacts –...
  • Page 16: Important Information

    12VDC backup battery pack is recommended. (PP-1) • Increase the separation between the equipment and receiver. Available from United Security Products. • Connect the equipment into a different outlet so that the equipment and receiver are on different branch circuits.
  • Page 17 AD2000 SERIES FAQ SHEET Can the dialer be used as a stand-alone unit? Yes, Purchase USP part# PB12P to provide both main power and battery backup. The PB12P plugs right into the 12vdc input jack on top of the dialer. USP’s warranty dies not cover reverse polarity or lightning strikes and other acts of God.

Table of Contents