1. Options and Accessories
Hand held remote control with weekly program.
• Individual cool and heat set points.
• External sensor option:
RS01 for remote temperature sensing (1 required)
RS02 for average temperature sensing (2 required)
For details on where to purchase accessories, please contact SCI for your nearest
location or visit our web site at www.scillc.com
File: FMT-24-SUPER-PROG+FP_letter_rev1.doc | Rev. 1 | October 16 ,2007
1
2
3
4
5
6
7

Advertisement

loading
Need help?

Need help?

Do you have a question about the FMT-24-SUPER-PROG and is the answer not in the manual?

Questions and answers

Summary of Contents for SCI USA FMT-24-SUPER-PROG

  • Page 1: Table Of Contents

    RS01 for remote temperature sensing (1 required) RS02 for average temperature sensing (2 required) For details on where to purchase accessories, please contact SCI for your nearest location or visit our web site at www.scillc.com File: FMT-24-SUPER-PROG+FP_letter_rev1.doc | Rev. 1 | October 16 ,2007...
  • Page 2: Installation Instructions

    2. Installation Instructions It is very important to find the right place to install the Flush Mount unit. Please make sure to follow all the installation instructions in order to get an accurate reading of the temperature. General points to follow: •...
  • Page 3: Wiring Connections

    3. Wiring Connections If you have the super model, make sure that you choose the right configuration - please see # 4 Rc-Rh - If one transformer is in use, Rc-Rh must be shorted - (Default from Factory) Table 3.1 - Connections for all applications Terminal Function ETN...
  • Page 4: Dip Switch Configuration And External Sensor Connection

    IMPORTANT! Before making any changes in the dipswitch disconnect electricity in the main board. 4. DIP Switch Configuration and External Sensor Connection DIP Switch Location The DIP switch is located on the top of the back side of the thermostat (above the connectors).
  • Page 5 External sensor connection - option Important! The external sensor must be SCI type. Table 4.4 - N.TC. Sensor: Temperature ~ Resistance Characteristics Temp °C 10.0 12.8 15.6 18.3 21.1 23.9 26.7 29.4 32.2 Temp °F Res. k 115.8 100.9 88.1 77.1 67.7 59.6...
  • Page 6: Operating Manual

    5. Operating Manual On/Off • Press the ON button to turn the thermostat ON or OFF - the word "ON" or "OFF" will appear on display. 5.2 Set Temperature • Press the “+” or “-” buttons – “COOL” will appear on display and the set temperature for cooling will flash.
  • Page 7 * In Heat mode, with Oil/Gas heat configuration (i.e., furnace): AUTO FAN - Fan will never be activated. FAN ON - The Fan will work continuously. • Press the ON button to return to normal display. 5.4 Lock/Unlock the thermostat button Use the Lock option to prevent users from making unwanted changes.
  • Page 8 5.5 Programming The thermostat is a 5-1-1 programmable; weekdays Monday through Friday, Saturday and Sunday both have individual programs. There are four program events per day: 1-Wake, 2-Day, 3-Return, 4-Sleep Switch between Programmable/Non Programmable configurations • Press and hold the ON button (10 seconds) – The word “Program” will either appear on display or disappear from display.
  • Page 9 Program Chart...
  • Page 10: Technician Settings

    6. Technician Settings 6.1 Adjust temperature limits for cool and heat, and offset for temperature reading. • Set temperature to 50°F. • Wait until the display • Press and hold the SELECT button (5 sec.) – “COOL” and the temperature limit for cooling will appear on display.
  • Page 11 7. RT04 - Hand Held Remote Control - Option The remote control is Infrared; the remote must be pointed at the thermostat to operate. Every time you change parameters in the Remote Control, you must send it to the thermostat by pressing the ON/SEND button.
  • Page 12 Temperature Set Point In Cool Mode: • Press the “+” or “-” buttons - “COOL” and set temperature for cooling will flash. • Using the “+” and “-” buttons, adjust the set temperature for cooling. • Press the ON/SEND button to send the information to the thermostat.
  • Page 13 The thermostat keeps a minimum differential of at least 1 degree between Heat set and Cool set (Heat is always less than Cool). Real Time Clock and Day • Press the SELECT button – “CLOCK SET” will flash. • Press the “+” or “-” buttons - the hours will flash. •...
  • Page 14 • Press the “+” or “-” buttons, “PROGRAM 1” & “START” (flashing) will appear on display. • Press the “+” or “-” button - the hours will flash. • Adjust the hours using the “+” and “-” buttons.
  • Page 15 • Press the SELECT button - the minutes will flash. • Adjust the minutes using the “+” and “-” buttons. • Press the SELECT button again – “COOL” (flashing) & the set temperature for cooling will appear on display. • Adjust the set temperature for cooling using the “+”...
  • Page 16 • Press the SELECT button: “PROGRAM 4” & “START” (flashing) will appear on display. • Press the “+” or “-” buttons and adjust the hours, minutes and temperature, the same way as in PROGRAM 1 • “SEND” will flash, press ON/SEND button to send the information to thermostat.