TAC4 DG + TCP/IP / GPRS

Installation and maintenance

Status: 06/2013
Paul Wärmerückgewinnung GmbH
August-Horch-Straße 7
08141 Reinsdorf
Germany
Tel.: +49(0)375 - 303505 - 0
Fax: +49(0)375 - 303505 - 55

Advertisement

Table of Contents
loading

Summary of Contents for Paul TAC4 DG + TCP

  • Page 1: Installation And Maintenance

    TAC4 DG + TCP/IP / GPRS Installation and maintenance Status: 06/2013 Paul Wärmerückgewinnung GmbH August-Horch-Straße 7 08141 Reinsdorf Germany Tel.: +49(0)375 - 303505 - 0 Fax: +49(0)375 - 303505 - 55...
  • Page 3: Table Of Contents

    Table of contents Preamble ..........................2 Introduction ..........................2 Safety ............................2 Used symbols ........................... 2 Functionalities of the regulation ..................3 Operating principle ........................ 4 Which module to choose – TCP/IP or GPRS? ..............4 Configuration and programming of the TAC4 TCP/IP or GPRS module ......5 Configuration file ........................
  • Page 4: Preamble

    If you have any questions that have not been answered or have not been sufficiently answered in this documentation, please contact the company Paul Wärmerückgewinnung GmbH. We will be glad to help you.
  • Page 5: Functionalities Of The Regulation

    Functionalities of the regulation The TAC4 DG controller is mounted in the units of maxi-series. The functionalities of this TAC4 DG control board are described in detail in the “Operating instructions TAC4+RC” manual. The TAC4 DG control board provides the following functionalities: •...
  • Page 6: Operating Principle

    3 Operating principle The TAC4 TCP/IP and GPRS modules are automated units with a built-in web server. Once programmed, the module contains software composed of web pages used for the configuration, control and display of TAC4 units connected to this module. Basic diagram: = MODBUS RTU communication = Access to the TAC4 MODULE web pages.
  • Page 7: Configuration And Programming Of The Tac4 Tcp/Ip Or Gprs Module

    5 Configuration and programming of the TAC4 TCP/IP or GPRS module The TAC4 TCP/IP or GPRS is delivered non-programmed. Programming is carried out in two steps: Entry of configuration settings: via the website http://TAC4.atmdata.be (you will need an SD card, maximum 2GB (not supplied)). Programming of the module using an SD card: follow the procedure in paragraph 5.2.
  • Page 8: Installation And Connection Of The Tac4 Tcp/Ip Or Gprs

    6 Installation and connection of the TAC4 TCP/IP or GPRS Support of the module Antenna (only for GPRS module) ETHERNET cable RS485 communication terminal block to TAC4 circuits and 24VDC power supply block Mounting screw on the support Figure 2 1) For the GPRS module, mount the antenna supplied with the TAC4 GPRS module and install the SIM card (not supplied) (see Figure 1).
  • Page 9: Pc Configuration To View Web

    7 PC Configuration to view web pages Compatible Web browser “Internet explorer” must be used to view Web pages. Other browsers are not compatible! Installation of the “WebFormViewSetup.exe” viewer To view the pages, you must install the “WebFormViewSetup.exe” viewer on your PC. This application can be downloaded from: http://TAC4.atmdata.be.
  • Page 10: Visualization

    Visualization The pages of this menu are used to view all the settings of the TAC4 unit with which you communicate (the address and the name of the unit are indicated at the top of the page). This menu comprises different sub-categories presented in the form of tabs. Synoptic 8.2.1 The “Synoptic”...
  • Page 11: I/O Status

    All the temperatures measured by the sensors of the unit The operating time of the unit. I/O status 8.2.5 The “I/O status” tab shows summary of the status of all inputs and outputs on the TAC4 control board. Configuration 8.2.6 The “Configuration”...
  • Page 12: Time Table

    Time table The ‘Time table” menu is used to program the operating mode and the setting points for the fans, the supply temperature and the position of the bypass on a weekly basis. Click on the box containing the time slot to open the configuration window of the corresponding time slot. Seasonal management of the bypass and the cold and hot coils is provided under the Seasonal manager tab.
  • Page 13: Tac4 Network

    TAC4 Network The “TAC4 Network” menu is used to configure and supervise all the units present in the network. Configuration 8.6.1 The “Configuration” tab is used to add/remove and to address units on the network. Each TAC4 unit is factory programmed with the address Modbus 1. To network several units, the different units must be re-addressed.
  • Page 14: Alarm Warning

    Alarm warning 8.6.3 The “Alarm warning” tab is used to select the type of alarms to be sent and to configure the dispatch by SMS and/or by e-mail. To select the types of alarm for which you want to send a message, tick the boxes of the desired alarms. Remember only the units present in the “Overview”...