Rheem 871018 Service Instructions Manual page 42

18, 20,24, 26l integrity electronic gas continuous flow water heater
Hide thumbs Also See for 871018:
Table of Contents

Advertisement

Fault Finding Tests 14 – 22
Isolate power when conducting resistance tests. "Live" components present
during voltage tests, exercise caution.
Solenoid
Normal
Test
Valve
Voltage
14
GISV
1
18
2
3
Tests 16 and 17 - Diagnostic Point 10
Test 16 – Conduct test with water flowing
Measure the voltage with connector B
plugged
into
PCB.
between DC1.5 and 8.0V.
Test 17 – Isolate power before conducting
test.
Measure the resistance with connector B
unplugged from the PCB. Normal resistance
is between 42 ohms and 97 ohms.
TM031 Integrity 18, 20, 24, 26L Service Instructions REV: B
D.O.I: February 2008
This document is stored and maintained electronically by
Tests 14, 15, 18, 19, 20 and 21
Diagnostic
Test Point
Point
9 Yellow
11
10 Black
3 Red
13
10 Black
4 White
14
10 Black
5 Blue
15
10 Black
Normal
voltage
is
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled"
NOTE:
Measure the voltage with connector L
plugged into PCB
Measure the resistance with connector L
unplugged from the PCB
Solenoid
Test
Valve
Resistance
15
GISV
1
19
2
3
Test 22 – Diagnostic Points 6 and 7
Error
Maintenance
Diagnostic
Code
display code
4y:
Combustion
32
Chamber
Thermistor
5y: Hot
33
Water Outlet
Thermistor
42
Normal
Test Point
9 Yellow
10 Black
3 Red
10 Black
4 White
10 Black
5 Blue
10 Black
Test Point
Point
5 White
6
7 Black
4 Red
7
7 Black
Diagnostic
Point
11
13
14
15
Measured
Value
@20ºC –
10.3 kilo-
ohms
@40ºC –
4.9 kilo-
ohms