Instructions For Handling Semi-Conductors - Centrum GEB100 Service Manual

Video cassette recorder
Table of Contents

Advertisement

CBA
Tweezers
2. Installation
(1) Using desoldering braid, remove the solder from
the foil of each pin of the flat pack-IC on the CBA so
you can install a replacement flat pack-IC more
easily.
(2) The " I " mark on the flat pack-IC indicates pin 1.
(See Fig. S-1-7.) Be sure this mark matches the 1
on the PCB when positioning for installation. Then
presolder the four corners of the flat pack-IC. (See
Fig. S-1-8.)
(3) Solder all pins of the flat pack-IC. Be sure that none
of the pins have solder bridges.
Example :
Pin 1 of the Flat Pack-IC
is indicated by a "
Presolder
CBA
Fine Tip
Soldering Iron
Flat Pack-IC
Fig. S-1-6
" mark.
Fig. S-1-7
Flat Pack-IC
Fig. S-1-8
Instructions for Handling
Semi-conductors
Electrostatic breakdown of the semi-conductors may
occur due to a potential difference caused by electro-
static charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1MΩ) that is prop-
erly grounded to remove any static electricity that may
be charged on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate
with proper grounding (1MΩ) on the workbench or
other surface, where the semi-conductors are to be
placed. Because the static electricity charge on cloth-
ing will not escape through the body grounding band,
be careful to avoid contacting semi-conductors with
your clothing.
<Incorrect>
<Correct>
1MΩ
1-3-3
CBA
Grounding Band
1MΩ
CBA
Conductive Sheet or
Copper Plate
NOTE_1