IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS
SAFETY NOTICE: If this stove
is not properly installed, a house
fi re may result. For your safety,
follow the installation instructions.
Contact local building or fi re officials
about restrictions and installation
inspection requirements in your
area.
TESTED and LISTED to CAN/ULC S627
AND UL 1482
Meets the Environmental Protection
Agency's July 1990 Particulate Emission
Standards
270412-20
INSTALLATION
AND OPERATING
INSTRUCTIONS
MODEL: TN19
SERIES: A
TN19
SERIAL #
5055.551

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TN19 and is the answer not in the manual?

Questions and answers

Summary of Contents for True North TN19

  • Page 1 Contact local building or fi re officials about restrictions and installation AND OPERATING inspection requirements in your area. INSTRUCTIONS TESTED and LISTED to CAN/ULC S627 AND UL 1482 Meets the Environmental Protection MODEL: TN19 Agency's July 1990 Particulate Emission Standards SERIES: A 270412-20 TN19 5055.551...
  • Page 2: Table Of Contents

    Minimum Clearance to Combustibles ................. 7 Through Wall Installations ....................10 Listed Chimney and Chimney Connector ................. 12 Firebrick Installation ..................15 Appendix A ......................16 Troubleshooting ........................ 16 Replacement Parts ......................17 Notes ..........................18 Label ..........................19 TN19 270412-20...
  • Page 3: Safety And Maintenance

    PLEASE SAVE THESE INSTRUCTIONS Please read this entire manual before you install and 4. DOOR GASKETS - The gasket used for the True North use your new room heater. Failure to follow instruc- (5/8" medium density fi berglass rope) requires only light tions may result in property damage, bodily injury, pressure to seal.
  • Page 4: Creosote

    Proper clearances are critical during such a fi re. Chimney fi res are easy to detect; they usually involve one or more of the following: -Flames and sparks shooting out of the top of the chimney -A roaring sound -Vibration of the chimney TN19 270412-20...
  • Page 5: Operation

    Normal Operation Your True North heater is designed for maximum overall efficiency at a moderate fi ring rate. Overfi ring is hazardous 1. Set air control to a desired setting. If smoke pours and a waste of fuel.
  • Page 6: More Wood, More Heat

    If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in closed container until all cinders have thoroughly cooled. Other waste should not be placed in this container. TN19 270412-20...
  • Page 7: Stove Dimensions

    6 1/2” 7” 17 1/2” 13” 6 1/2” 13” 26” 26” 7” 16” 16” 16” Alcove: Min. Height 7 1/2' Max. Depth 3' Double Wall Connector - Mobile Home 10” 13” 23 1/2” 16 1/2” 30” 20” 13” TN19 270412-20...
  • Page 8: Residential

    10 feet (3 m.). The installation must meet all local codes. Do not connect this unit to a chimney fl ue serving another appliance. Minimum system height is 12 feet (3.0 m.) (measured from top of appliance). TN19 270412-20...
  • Page 9 (1219 mm) Non-combustible fl oor protector Hooded vent or * 4" diameter air inlet with rodent screen 90 elbow turned down * If the crawl space is well ventilated it is not necessary to extend air inlet to outside TN19 270412-20...
  • Page 10: Through Wall Installations

    Supports shall be securely fastened to wall surfaces on all sides and shall be sized to fi t and hold chimney section. Fasteners used to secure chimney section shall not penetrate chimney fl ue liner. Clearance: 2 in. (51 mm) TN19 270412-20...
  • Page 11: Mobile Home Installation

    NOTE: Longer chimney lengths and different pitch fl ashings may be used. All other parts listed must be installed (see Figure #4, Page 13). Install all components to the connec- tor or chimney manufacturer's installation requirements. Consult your chimney supplier for installation advice. TN19 270412-20...
  • Page 12: Listed Chimney And Chimney Connector

    CL48 SDP-P SDT-P 2' Chimney length T-24 HS 24 CL24 SDP-P SDT-P Roof fl ashing RF17 T-SFA 8RFFU SDP-F SDT-F Storm collar T-SC TGSC PL-ASCG SDP-SC SDT-SC Spark arrestor rain cap XCPE RCSA RCSA T-CT 6PL-MPC SDP-C SDT-C TN19 270412-20...
  • Page 13: Floor Protector

    If blockage occurs, fl ue gases may enter living space. TN19 270412-20...
  • Page 14: Optional Blower

    Proper blower speed matched with air control setting will ensure peak performance from your stove. Operate as follows: - Except on "High" setting, wait 30 minutes before turning on blower to desired setting. ELECTRICAL RATING 115V, 60Hz, 1.1A FIG. #7 SPEED CONTROL BLOWER POWER CORD TN19 270412-20...
  • Page 15: Firebrick Installation

    1) Place 4 full-size fi rebricks against the rear wall. 2) Next install fi rebricks on the bottom of the unit. Use a total of 8 full-size. 3) Finally install 4 full-size fi rebricks on each side of the fi rebox as shown. TN19 270412-20...
  • Page 16: Troubleshooting

    11, Proper Draft. Stove Won't Burn 1. Combustion air supply blocked - Check outside air supply for obstruction - Check that room air cover is removed 2. Draft too low - Chimney plugged or restricted, inspect and clean TN19 270412-20...
  • Page 17: Replacement Parts

    8.... Rear Brick Rail(c/w 2 screws) ......7625 9.... Quadrant Assembly ....... TRNO.7617 10 ..Fan(Optional) ....... TRNO.19BLOWA All parts may be ordered from your nearest True North dealer. Contact True North for the location of the dealer nearest you. FIG. #13...
  • Page 18: Notes

    Notes TN19 270412-20...