Datatek DT-6061 User Manual

Ip-pad application
Hide thumbs Also See for DT-6061:

Advertisement

Quick Links

DT-6061
U
'
M
SER
S
ANUAL
IP-PAD A
PPLICATION
V
1.0.16
ERSION
721 Route 202-206
Bridgewater, NJ 08807
fax: 908.218.1736
phone: 908.218.0500
email: sales@datatekcorp.com
http://www.datatekcorp.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DT-6061 and is the answer not in the manual?

Questions and answers

Summary of Contents for Datatek DT-6061

  • Page 1 DT-6061 ’ ANUAL IP-PAD A PPLICATION 1.0.16 ERSION 721 Route 202-206 Bridgewater, NJ 08807 fax: 908.218.1736 phone: 908.218.0500 email: sales@datatekcorp.com http://www.datatekcorp.com...
  • Page 2 11/01/00 Datatek Applications Inc.
  • Page 3: Table Of Contents

    CONTENTS INTRODUCTION ........................4 1.1 DT-6061 IP-PAD A ) ...........4 WITH PPLICATION YPICAL ONFIGURATION 1.2 A ....................5 PPLICATION PECIFICATIONS 1.3 A & O ..............5 PPLICATION ASIC RCHITECTURE PERATION 1.4 IP-PAD A ..................6 PPLICATION ONFIGURATION APPLICATIONS COMMANDS ....................7 2.1 I ......................7 NPUT ONVENTIONS 2.2 L...
  • Page 4: Introduction

    X.25 Network Elements In the above configuration, there is one circuit carrying X.25 LAPB frames from the DT-6061 to a DT-4000 connected Network Element (NE) or a SAM connected NE. The X.25 Network Element may be anywhere on the available networks (both BNS and IP) as the above diagram depicts . IP Hosts access the virtual circuits on these Network Elements via a TCP port number.
  • Page 5: Application Specifications

    . The same is true of terminal and PC devices on either the BNS or the IP network. 1.2 A PPLICATION PECIFICATIONS Number of X.25 devices per DT-6061 Number of Virtual Circuits per X.25 Device 1-100 PAD Service Yes (Per Virtual Circuit) X.25 Pass-Through Service...
  • Page 6: Ip-Pad Application Configuration

    PPLICATION ONFIGURATION The configuration of the X.25 application takes place on its OA&M port. That is TCP port number 10000 + its instance number in the DT-6061. The configuration required for the IP-PAD application is: • Per application: This is the TCP port number to be used as a base for a range of TCP ports the application instance shall use.
  • Page 7: Applications Commands

    P P L I C A T I O N S O M M A N D S The DT-6061 software is composed of two components. One component, called the Platform, exists to support all applications. The second component is comprised of the individual application (s) .
  • Page 8 TCP port number. The first VC would be at TCP 30001, and so on. When the X.25 link is to be on an incoming TCP session, the type would be set to rcv. The X.25 link would reside at the TCP port specified by the base parameter. 11/01/00 Datatek Applications Inc.
  • Page 9 The echo option refers to reference #2 in the X.3 parameter list. When set to OFF, the IP-PAD will not echo characters back to the IP endpoint. When set to the value of ON, all characters are to be echoed back to the IP source. 11/01/00 Datatek Applications Inc.
  • Page 10 The VC <#> parameter will display the configuration information for a particular X.25 virtual circuit on the link. The virtual circuit number is in the range of 1 through the maximum number supported by the application. 11/01/00 Datatek Applications Inc.
  • Page 11 2.3.12 R X.25 O ESTART PERATION Syntax: restart The restart command is only visible when the application is logged in. The command is used to manually initiate a protocol restart of the X.25 link and packet layers. 11/01/00 Datatek Applications Inc.
  • Page 12: Application Software Installation & Upgrade

    N S T A L L A T I O N P G R A D E An application may be initially installed, or upgraded, using the install command. Refer to the DT-6061 Platform User’s Manual and refer to the section titled: Application Software Installation & Upgrade 11/01/00...
  • Page 13: Appendix A - Ip-Pad Measurements Available

    Number of Interrupt Packets Received Exception Number of Interrupt Confirm Packets Received Exception Number of REJ Packets Received Exception Number of RNR Packets Received Exception Number of Reset Request Packets Received Exception Number of Reset Confirmation Packets Received Exception 11/01/00 Datatek Applications Inc.
  • Page 14: Support For X.3 Pad Parameter Values

    Line Folding 0 – No line folding Binary Speed 18 – 64000bps For Reporting Only Flow Control of the 0 – No use of X-ON These are functions of the and X-OFF DT-4000 and SAM devices. 11/01/00 Datatek Applications Inc.
  • Page 15 0 – No extended Data Forwarding Signals Display Interrupt 0 – No display interrupt Display Interrupt 0 – No display interrupt Confirmation confirmation. Diacritic Character 0 – Basic Coding Coding Extended Echo Mask 0 – No Extended Echo Mask 11/01/00 Datatek Applications Inc.
  • Page 16: Warranty

    The warranty period for hardware shall be one year from the date of delivery, and the warranty for software shall be 90 days from the date of delivery. Replacements and repairs are guaranteed for the longer of the remaining original warranty period or 90 days. ©Copyright 2000 Datatek Applications Inc. All Rights Reserved Printed in USA 11/01/00 Datatek Applications Inc.

Table of Contents