E-Tech ET8 User Manual

Alarm control panel and dialler

Advertisement

Quick Links

E - T E C H E T 8 A L A R M C O N T R O L P A N E L A N D D I A L L E R
USER'S MANUAL
E-TECH ET8 CONTROL PANEL V4 – USER'S MANUAL, REVISION 1
A$12.00 INC GST
Versions commencing November 2001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ET8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for E-Tech ET8

  • Page 1 E - T E C H E T 8 A L A R M C O N T R O L P A N E L A N D D I A L L E R USER’S MANUAL E-TECH ET8 CONTROL PANEL V4 – USER’S MANUAL, REVISION 1 A$12.00 INC GST...
  • Page 2 Australian Communications Authority Document Part Number: 890–265 TELECOMMUNICATIONS COMPLIANCE For product: 100–191 ET8 LED Control Panel (V4) 100–688 ET8 LCD Control Panel (V4) © 2001 E-Tech Security Products Pty Ltd ACN 000 110 110 ET8 V4 installer Specifications may change without notice.
  • Page 3: Table Of Contents

    Telephone Number programming ....... 19 Monitoring, Central Station ........20 Monitoring, Audible ..........21 Wireless Accessories ..........20 Remote Operation by Telephone ......22 E-TECH ACCESSORIES ......... 24 Wireless Accessories ........... 25 Troubleshooting ............26 Installation Record ............ 27 OPERATION SUMMARY .......... 28...
  • Page 4: Features

    True Dynamic Battery Test every time the Panel is armed / disarmed and every hour • Area Partitionable (2 Areas). Any Zone can be programmed to any area, as well as common areas E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 5: Introduction

    INTRODUCTION The E-Tech ET8 micro computer based 8 zone Arming the system may be done through the control panel is the heart of your security keypad or with the use of optional Radio Keys system to which all your detection devices for Arming by remote control from outside the connect.
  • Page 6: Keypad

    KEYPAD The ET8 control panel may be supplied with either the LED keypad (100-192) or the E-Tech LCD Keypad (100-667). The keypad provides important visual and audible indications and is the main interface for operating and programming the ET8 control panel.
  • Page 7: Keypad Indicators

    Ready to Arm Not ready to Arm KEYPAD BEEPER SOUNDS 1 beep Each key press 3 beeps Valid command 1 long beep Error Mains Power is off 10 beeps Panel Battery is low E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 8: Operation By Keypad

    Common Area zone/s to be shared by both Areas. All control panel operations are controlled by the ET8 LED or LCD keypad except if an For example, Office A and Office B operate as optional key switch or radio control equipment separate areas but the entrance foyer used by is installed.
  • Page 9: Arming

    Backup Battery is low. is Unsealed at the end of exit time. One long beep indicates an invalid entry or an alarm is outstanding and needs to be reset by entering your User Code first. E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 10: Disarming

    If Memory Mode. this occurs, Disarming your control panel will reset the alarm. The cause of the alarm can be identified by entering the Alarm Memory Mode as described on page 15. E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 11: Monitor Mode

    Monitor Mode by pressing the OFF button twice within 4 seconds. (Your installer must enable The panel must be fully Disarmed before Arming Radio Key Monitor Arming for this to work). in Monitor Mode. E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 12: Panic

    DURESS IS NORMALLY NOT ENABLED. TO To Disarm and send a DURESS alarm, prefix ENABLE THE DURESS FUNCTION, CONSULT your User Code with one of the digits 5, 6, 8 or YOUR INSTALLER 9 when Disarming. E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 13: Fire Alarm

    2. If Medical Alarm Report has been enabled by your installer 2. If Medical Alarm Report has been enabled by your installer Medical Alarm does not sound sirens. Medical Alarm does not sound sirens. E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 14: Excluding Zones

    • EXCLUDE E works only when the panel is Disarmed. • EXCLUDE [User Code] E works in any state. • EXCLUDE [User Code] E can only exclude the zones in the Area assigned to that code. E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 15: Alarm Memory

    Panel Disarmed TAMPER Tamper alarm (Siren cover, panel etc) EXCLUDE Panic alarm BATTERY Low Battery MAINS Mains power failure RADIO, BATTERY, ZONE Radio Device battery low RADIO, BATTERY, ARM Radio Key battery low E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 16: Operation By Radio Key

    Press the OFF button to reset a Panic alarm * The E-Tech Radio Key is optional and is not supplied with any E-Tech control panels as standard * E-Tech radio products require a E-Tech Radio Interface (100-200) to be fitted to the control panel.
  • Page 17: Programming

    User Codes may need to be re-programmed if a person has forgotten their code, to give a If your E-Tech ET8 panel is monitored by a new user access to the system or to give Central Station, the Follow Me number is someone temporary access.
  • Page 18: User Code Programming

    To exit Program Mode EXAMPLES The panel must be in Program Mode. (Program light ON) P26E To program Entry Delay Time1 to be 15 seconds: P28E To program Exit Delay Time to be 40 seconds: E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 19: Telephone Number Programming

    Follow Me Telephone Number: * For a list of option numbers, see the Programming Options Table on page 17 To enter PROGRAM MODE To exit PROGRAM MODE ENTER ENTER [Master Code] [Master Code] E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 20: Monitoring, Central Station

    MONITORING CENTRAL STATION MONITORING CENTRAL STATION MONITORING The ET8 control panel has an on-board digital dialler which can send detailed alarm messages to a Central Monitoring Station. MONITORED PREMISES TELEPHONE LINE MONITORING STATION The digital messages can include information about the zone or zones which caused the...
  • Page 21: Monitoring, Audible

    See page 19 for information on programming the Follow Me Telephone Number. AUDIBLE MONITORING SEQUENCE When triggered by an alarm, the ET8 will dial the programmed telephone number/s and output the audible message for 45 seconds or until it is acknowledged.
  • Page 22: Remote Operation By Telephone

    • If an alarm occurs which requires the ET8 to dial out while attempting remote control, the ET8 will treat the alarm as a priority, give a constant tone as a warning and then hang up.
  • Page 23 1. Dial the ET8 telephone number. Listen for one double ring then hang up. 2. Wait 10 seconds, then dial the ET8 telephone number again. The ET8 will answer immediately and gives a 2 second beep followed by low tone. 3. PRESS...
  • Page 24: E-Tech Accessories

    Monitors - even digital video recorders and emergency buttons, roller door reed switches remote telephone video systems. and the unique E-Techensor™ vibration sensor for highly effective perimeter protection. E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 25: Wireless Accessories

    E-Tech ET16, D24 panels. With separate buttons for ON The E-Tech radio Keypad is suitable for use as (Arm), OFF (Disarm) and PANIC functions. a portable keypad or for adding an extra Includes long life lithium battery.
  • Page 26: Troubleshooting

    Cannot enter Program Mode The panel is Armed. Disarm the panel before attempting to Only the Master Code can enter enter Program Mode. Program Mode. Try again using the Master Code. E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 27: Installation Record

    User Code 9 P19E User Code 10 P20E User Code 11 P21E User Code 12 P22E User Code 13 P23E User Code 14 P24E User Code 15 P25E © 2001 E-Tech Security Products E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...
  • Page 28: Operation Summary

    ENTER ALARM MEMORY or... [User Code] Press repeatedly to display the last MEMORY Press repeatedly to display 30 events the last 30 events ENTER To exit Memory mode To exit Memory mode E-TECH ET8 V4 CONTROL PANEL - USER MANUAL...

Table of Contents