  • Page 1: Service Manual

    Service Manual KUD-WC1113 KUD-WD1117...
  • Page 2 DRUM WASHING MACHINE SERVICE GUIDE...
  • Page 11 PARTS NAME PARTS CODE DESCRIPTION UNITS REMARK PCB AS 3610PCB490 MEX COMBI COMBO 3610PCB495 MEX WASHER WASHER...
  • Page 14 PARTS NAME PARTS CODE DESCRIPTION UNITS REMARK UNIT STATOR BL C 36189L4810 ¥Õ265X30H,36SLOT,2SNESOR,WS2A30G001 HEATER WASH 3612801740 120V 1KW.1R0A721005.RW8TF1PE.IRCA UNIT BUBBLE PUMP 36189L4130 100-130 DBK-115DC RP-CUSH COM.
  • Page 16 PARTS NAME PARTS CODE DESCRIPTION UNITS REMARK...
  • Page 17 VALVE INLET 3615415070 100~130V,3WAY,RINSE GUIDEÀ,PP/BRACKET...
  • Page 19 PARTS NAME PARTS CODE DESCRIPTION UNITS REMARK...
  • Page 20 PCB FRONT AS PRPSSWAD27 FRONT,WASHER,PAIR0DRY COMBO PRPSSWAD28 FRONT,WASHER, KUD-WD1117 WASH...
  • Page 21 PARTS NAME PARTS CODE DESCRIPTION UNITS REMARK...
  • Page 22 "...
  • Page 24 "...
  • Page 38 4. HEATER 1) SPEC. OF HEATER Part Name heater wash heater dry Maker IRCA IRCA Power source 120V 120V Power Consumption 1000W 5% 1300W 5% Resistance 14.4 11.1 Current Density Temperature fuse 128 (exterior) Thermistator Combined in heater exterior Material SUS430 INCLOY800 Part Code...
  • Page 39 2) DIAGNOSIS OF THE FAILURE Failure Cause Diagnosis of Failure Solution Status Error Mode Can not Wiring Disconnectiona Check whether disconnected or not : See Fig. A Connecting the "H6" heat disconnecting point water Heater Wash Check whether disconnected or not : if normal, the Replacing Heater Wash "H6"...
  • Page 40 * Replaceing method of Heater and Temp. Sensor 1. Disassemble Connector 2. Disassemble EARTH and NUT for fixing heater 3. Replace heater & sensor 4. Assemble in the reverse order. Be sure to assemble in the order : Nut for heater-Nut for EARTH. * Structure of DUCT B As 1.
  • Page 41 5. MOTOR Rotor Insulator Core Insulator BLDC MOTOR Magnetic density flow of BLDC Motor Sequence diagram of BLDC MOTOR electromagnet generating high power by rotator (a permanent magnet) and stator (multiple coils)
  • Page 42: Dry System

    6. DRY SYSTEM 1) DRY SYSTEM DIVISION PARTS NAME DUCT COVER FAN MOTOR HEATER DRY DUCT B UNDER VALVE INLET(DRY) THERMOSTAT(Bie-METAL) THERMISTOR DUCT B UPPER FAN AS FUSE TEMPERATURE...
  • Page 43 2) DRY FUNCTION DIAGRAM T : Thermistor (CONTROL DRY DUCT HEATER S TEMPERATURE ) HEATER FAN MOTOR WATER SUPPLY CONDENSING DRUM DUCT DRAIN HOUSING 3) TEMP-TIME GRAPH DURING DRY CYCLE DRYING PROCESS ZONE INSIDE TEMPERATURE TEMP. OF DRUM PRE HEATING ZONE TIME...
  • Page 44 4) DRY COURSE COURSE DRY COURSE LOW TEMP. Heater control temperature is 60 On/70 Off LESS Heater control temperature is 95°C On/105°C Off, with good condition for ironing NORMAL Heater control temperature is 95°C On/105°C Off, drying time is 166 min MORE Heater control temperature is 95°C On/105°C Off, drying time is 216 min SELECTING TIME...
  • Page 45 5) TROUBLE SHOOTING OF DRY SYSTEM FIXED BY WASHER SCREW...
  • Page 46 OPEN TEMPERATURE(OFF) 150°…°æ 5°… CLOSE TEMPERATURE(ON) 120°…°æ 5°… ITEMS SPEC RATING VOLTAGE MOTOR 3700 10% DUCT FAN AS 1900 10% ROTAING DIRECTION...
  • Page 47 7) LACK OF DRY PERFORMANCE part name checking point checking results jurge repair method BELLOWS clogging heater was clean the bellow DUCT bellows duct overheated duct owing to poor air circulation BELLOW DUCT VALVE INLET no water supply VALVE INLET connect normally +Condensing from inlet valve...
  • Page 48 checking point part name checking results repaire method HEATER dry Heater is short or cut-off. replace the dry Heater. SENSOR TEMP. Thermistor is short or cut-off. replace the Thermistor. FUSE TEMPERATURE is cut-off. replace the FUSE TEMP. FUSE TEMPERATURE. HEATER THERMISTOR FUSE TEMPERATURE...
  • Page 49: Fan Motor

    part name checking results repair method disassemble process of Fan Motor FAN MOTOR fan motor failure replace Disassemble the DUCT AS from DUCT B AS. fan motor (SCREW 4 EA) DUCT COVER AS Disassemble FAN AS from DUCT COVER AS by using L-wrench.
  • Page 50 * Note that parts drawn with dashed lines are optional...
  • Page 51 Checking Methods Checking Methods Replacing methods Check if pump filter is full of lint. Clean the pump filter Check if pump impellor is blocked. remove all foreign substances Check the hose drain O condition: blocked. Clean the hose inside. Remove the pump filter, run spinning and check if If not, replace the pump pump impellor is hotaing quickly.
  • Page 52: Parts & Configuration

    1. PARTS & CONFIGURATION FIGURES PARTS NAME REMARKS FIXTURE UP/DOWN AS SPECIAL SCREW UP is shorter than SPECIAL SCREW DOWN. SPECIAL SCREW FIXTURE UP FIXTURE SPECIAL DOWN SCREW DOWN Use this part to remove UNIT SERVICE WRENCH FIXTURE UP/ DOWN. Adjust leg with this part.
  • Page 53 Adjusting Method Remarks If turned CW, the LEG ADJUST AS moves the washer upward. If turned CCW, the LEG ADJUST AS moves the washer downward. Adjusting Method Remarks Please fix the SPECIAL BOLT by rotating it CCW in order to prevent washer vibration.
  • Page 54 Item Part Name Checking Point 1 Replacing Thermistor Thermistor Dry Keep the Packing from seperating (Hold Packing when replacing) Keep the Packing from folding 2 Replacing Duct B As DUCT B AS & Check the sealing between Duct Pipe & Duct B AS &...