Little Giant 5-md-sc Insctruction Manual

Advertisement

Quick Links

Franklin Electric Co., Inc.
Oklahoma City, OK 73127
www.LittleGiantPump.com
CustomerService@lgpc.com
INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your product. Retain these instructions
for future reference.
The product you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. This product has been carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your item(s) carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING
TO
INSTALL,
YOUR PRODUCT. KNOW THE PRODUCT'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
SAFETY GUIDELINES
1. Make certain that the unit is disconnected from the power
source before attempting to service or remove any
component.
2. Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not use in explosive
atmospheres. Pump should only be used with liquids
compatible with pump component materials.
3. Do not handle pump with wet hands or when standing on a
wet or damp surface or in water.
4. This pump is supplied with a grounding conductor and/or
grounding type attachment plug. To reduce the risk of electric
shock, be certain that it is connected to a properly grounded
grounding type receptacle.
5. In any installation where property damage and/or personal
injury might result from an inoperative or leaking pump due to
power outages, discharge line blockage, or any other reason,
a backup system(s) and/or alarm should be used.
6. Support pump and piping when assembling and when
installed. Failure to do so may cause piping to break, pump to
fall, motor failures, etc.
ELECTRICAL CONNECTIONS
1. Check the pump label for proper voltage required. Do not
connect to voltage other than that shown.
2. If pump is supplied with a 3-prong electrical plug, the third
prong is to ground the pump to prevent possible electrical
shock hazard. DO NOT REMOVE the third prong from the plug.
A separate branch circuit is recommended. Do not use an
extension cord. Do not cut plug from the cord. If the plug is cut
or the cord is shortened, then this action will void the warranty.
5-MD-SC
5-MD-HC
TE-5-MD-SC
TE-5-MD-HC
CAREFULLY
BEFORE
OPERATE,
OR
SERVICE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
3. The National Electric Code requires that a ground fault circuit
interrupter (GFCI) be used in the branch circuit supplying
fountain pumps and other pond equipment. See your electrical
supplies dealer for this device.
4. To reduce the risk of electric shock, use only on portable self-
contained fountains no larger than five feet in any dimension.
CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER
ASSEMBLY AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP.
PUMP CONSTRUCTION
The patented Little Giant magnetic drive pump design consists
of a cylindrical drive magnet attached to the motor shaft which
rotates around a chemical resistant plastic separator housing.
Inside this housing is a magnet completely encapsulated in
chemical resistant plastic, and fixed to the impeller. The impeller
assembly is free to rotate on a spindle that is supported at both
ends. The spindle is held captive and does not turn. Front and
rear thrust washers are utilized as wear bearings. The washers are
held captive and do not revolve. This prevents wear on the shaft.
With the magnetic coupling the motor drives the impeller. This
coupling eliminates the conventional shaft seal and its possibility
of leakage.
Two series are available. The HC series handles highly corrosive
chemicals at elevated temperatures because of the unique
materials used in its construction. The SC series handles semi-
corrosive fluids. Both series are available with various size pumps,
and are available in 115V or 230V, 50/60 Hz versions.
The HC models utilize a carbon bushing between the impeller and
spindle. The use of this carbon bushing will allow these pumps
(HC series) to run dry (without fluid) for up to eight hours at a time.
Do not allow the SC models to run dry. They do not have the
carbon bushing and heat build up caused by friction will damage
the parts when SC models are run dry.
PUMP MATERIALS
The plastic parts on SC series pumps are made of glass-filled
polypropylene. The plastic parts on the HC series pumps are
glass filled PPS. The spindle shaft which is stationary and the
captive thrust washers (front and rear) are alumina ceramic. The
O-ring seal is Nitrile for the SC series, and Fluoroelastomer (FKM)
for the HC series. The HC series utilizes a pure carbon bushing in
the impeller to enable the pump to run dry for periods up to eight
hours at a time.
INSTALLATION
Your Little Giant pump is delivered to you completely pre-assembled
and pretested from the factory. It is ready for immediate use. The
pump may be installed in any position. It may be mounted
vertically with the pump head down. Proper plumbing connections
should be made. See specification table to determine what size
intake and discharge your pump has. Use a thread sealer on all
pipe connections and hand tighten only. NOTE: On HC models a
roll of PTFE pipe seal tape is supplied. Do not use a wrench to
tighten the HC model connections. Excessive force may damage
the plastic part. Make sure the wing nuts are tight before operating
the pump.
Motor nameplates list all electrical data and wiring schematic.
Make sure the pump is connected to proper voltage before operating.
When wiring pumps with no plug, the green (or green/yellow) wire
is the ground. The other two wires are line (live).
Do not allow the SC models to run dry (without fluid). However,
because the HC models utilize a carbon bushing in the impeller
they may be allowed to run dry for periods up to eight hours at a
1

Advertisement

Table of Contents
loading

Summary of Contents for Little Giant 5-md-sc

  • Page 1 5. In any installation where property damage and/or personal Your Little Giant pump is delivered to you completely pre-assembled injury might result from an inoperative or leaking pump due to and pretested from the factory. It is ready for immediate use. The power outages, discharge line blockage, or any other reason, pump may be installed in any position.
  • Page 2: Connexions Electriques

    4. If pump is tripping circuit breakers, GFCI, or not operating borne de mise à la terre. properly after cleaning, return to a Little Giant authorized 5. Dans le cas de toute installation où des dommages matériels service center. DO NOT attempt repairs yourself.
  • Page 3: Matériaux De Construction

    à la pompe de tourner à vide pendant un maximum avec mise à la terre (GFI) ou si elle fonctionne mal après le de 8 heures consécutives. nettoyage, Retour pompe à Little Giant autorisé service center. AVERTISSEMENT NE PAS essayer de la réparer soi-même.
  • Page 4: Conexiones Electricas

    El diseño patentado de impulsión magnética de la bomba y protegida contra salpicaduras. Estas bombas no son modelos Little Giant está compuesto por un imán cilíndrico de impulsión autocebantes. Deben instalarse de tal manera que la cabeza conectado al eje del motor el cual gira alrededor de una caja de bombeo (voluta) se encuentre inundada al momento en que plástica separadora resistente a sustancias químicas.
  • Page 5: Instrucciones De Servicio

    (GFCI) o si no funciona apropiadamente después de limpiarla, Regresar a Centro de Servicio Autorizado Little Giant, NO intente efectuar las reparaciones usted mismo. 5. Asegúrese de que el cordón eléctrico esté en buen estado y que no tenga hendiduras ni cortes.
  • Page 6 NOTE: Motor configuration may vary from model to model. • NOTE : La configuration du moteur peut varier selon le modèle. • NOTA: La configuración del motor puede variar de modelo a modelo. NOTE: TE models are not equipped with metal base. They use the polypropylene adaptor/base. • NOTE : Les modèles de la série TE ne sont pas pourvus d’une base métallique. Ils sont munis d’une base/adaptateur de polypropylène.
  • Page 7: Limited Warranty

    LIMITED WARRANTY AND/OR (2) DEFECTS THAT WERE NOT FOUND AT THE TIME OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS. THIS WARRANTY SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT. This Limited Warranty gives you specific legal rights. You may have other rights, which vary according to the applicable laws and regulations.
  • Page 8 Pour l’aide technique, entrez s’il vous plaît en contact ......800.701.7894 Para la ayuda técnica, por favor póngase en contacto ......800.701.7894 www.LittleGiantPump.com CustomerService@lgpc.com Form 993235 - 06/2012 Rev. 001 Little Giant® is a registered trademark of Franklin Electric Co., Inc.

This manual is also suitable for:

5-md-hcTe-5-md-scTe-5-md-h

Table of Contents