Tobii C8 User Manual

C-series
Hide thumbs Also See for C8:
Table of Contents

Advertisement

Quick Links

Tobii C-Series User's Manual
User's Manual
Tobii C-Series
C8
C12
C15
CEye
Celebrating Communication

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tobii C8

  • Page 1 Tobii C-Series User’s Manual User’s Manual Tobii C-Series CEye Celebrating Communication...
  • Page 2 All rights reserved. © Tobii Technology AB The information contained in this document is proprietary to Tobii Technology. Any reproduction in part or whole without prior written authoriztion by Tobii Technology is prohibited. US Patent 7, 572,008 (applies to Tobii CEye) Tobii_manual_Cseries_V2_7_1_24052012_UsEng...
  • Page 3: Table Of Contents

    2.6 Child Safety Overview of the Tobii C8, C12 and C15 3.1 Key Features 3.2 Product Layout 3.2.1 The Tobii C8, Tobii C12 and Tobii C15 3.2.2 Ports, Sensors and Device Buttons 3.3 Preinstalled Software 3.4 Configuring the Device Batteries in the Tobii C-Series 4.1 Batteries...
  • Page 4 5.16.3 Restoring the Factory Settings of a C-Series Device: Tobii CEye Module & Eye Control 6.1 Installing the Tobii CEye Module 6.1.1 Mounting the CEye Module to the Tobii C12 or C15 6.1.2 Required Software 6.1.3 Installation of Eye Control Software from USB Stick 6.2 Using the Tobii CEye Module...
  • Page 5 6.2.4 Accessing the Tobii Eye Control Options 6.2.5 Creating a New Profile 6.2.6 Selecting Current User Profile 6.2.7 Deleting a Profile 6.2.8 Customizing the Interaction 6.2.9 Showing Track Status 6.3 Calibration 6.3.1 Starting Calibration 6.3.2 Interrupting Calibration 6.3.3 Customizing Active Eye 6.3.4 Improving Calibration Point(s)
  • Page 6: Introduction

    The C-Series device is available in three different sizes: the Tobii C8 with an 8.4” screen, the Tobii C12 with a 12.1” screen and the Tobii C15 with a 15.0” screen. The Tobii C12 and C15 can be used with the Tobii CEye, to enable eye control of the device.
  • Page 7: Package Contents

    Two rechargeable Lithium Ion (LiPo) batteries • A DC power adapter/charger including four different plugs for different regions • A carrying strap, extendable to shoulder strap, for the C8 and C12 • A User’s Manual (this document) • A Getting Started Guide •...
  • Page 8: Safety

    8.4 Appendix D: Technical Specifications section -- including, but not limited to, the Medical Device Standard (Class 1/Type B). Nevertheless, in order to ensure safe operation of your Tobii C-series device, there are a few safety warnings to bear in mind:...
  • Page 9: Mounting Warning

    However, should the device for any reason harm or damage someone or something due to falling, neither Tobii Technology nor any of its representatives will be responsible or liable for any damages or injuries which may arise. The mounting of devices from the C-Series is done entirely at the user’s own risk.
  • Page 10: Epilepsy Warning

    Tobii C-Series User’s Manual 2.5 Epilepsy Warning Some people with Photosensitive Epilepsy are susceptible to epileptic seizures or loss of consciousness when exposed to certain flashing lights or light patterns in everyday life. This may happen even if the person has no medical history of epilepsy or has never had any epileptic seizures.
  • Page 11: Overview Of The Tobii C8, C12 And C15

    A C-Series device has a color TFT display with a touch screen. The Tobii C8 has an 8.4” screen with an 800x600 pixel resolution. The Tobii C12 has a 12.1” screen with a 1024 x 768 pixel resolution. The Tobii C15 has a 15.0” screen with a 1024 x 768 pixel resolution.
  • Page 12: Ports, Sensors And Device Buttons

    Make sure that the connector matches the port and that you have positioned the connector correctly in relation to the port. Chapter 3 Overview of the Tobii C8, C12 and C15...
  • Page 13: Preinstalled Software

    • Double-click on the C-Series Hardware Options shortcut on the desktop, Go to Start menu > All Programs > Tobii > C-Series Hardware Options. Click C-Series Hardware Options, In the list to the left, select which hardware configuration you want to change.
  • Page 14: Batteries In The Tobii C-Series

    Batteries in the Tobii C-Series 4.1 Batteries The C-Series device has two battery compartments. The batteries for the Tobii C8 differ in size and capacity from those of the Tobii C12 and C15, see the Appendix C: Technical Specifications. Tobii C8 batteries: •...
  • Page 15: Checking Charge Level

    (even up to 20 minutes) before you see an LED indication that any charging is taking place. The battery IS being charged during this duration though it is a recovery charge raising the level enough to begin normal charging. Chapter 4 Batteries in the Tobii C-Series...
  • Page 16: Inserting And Releasing The Batteries

    Place the C-Series device face down on a flat surface. Insert a battery in the battery compartment. Press the battery down until it locks in place. You should hear a click that confirms that the battery is in a locked position. Chapter 4 Batteries in the Tobii C-Series...
  • Page 17 Place the C-Series device face down on a flat surface. Use both hands to slide the rubber feet apart on the battery. You will hear a click as they are released. Lift the battery up and out of the device. Chapter 4 Batteries in the Tobii C-Series...
  • Page 18: Using The Tobii C-Series

    Be aware that creating a new user and downloading updates from the internet could possibly compromise the system and software settings of the operating system that have been set and installed at Tobii Technology. Should the password window pop up, requiring a password, the default...
  • Page 19: C-Series Welcome Guide

    Tobii C-Series User’s Manual password on all C-Series devices is, “Tobii” (case sensitive). In order to type in the password, an external USB keyboard is required (not included). If you decide to change the password, be sure to write it down in a safe place for later use.
  • Page 20: C-Series Welcome Center

    To open the C-Series Welcome Center: • Navigate in Windows from your desktop to Start Menu > All Programs > Tobii > C-Series Welcome Center and click on the C-Series Welcome Center icon, • Navigate in Windows from your desktop to Start Menu >...
  • Page 21: C-Series Update Notifier

    To keep your C-Series Device running properly it is highly recommended that you update your Tobii Software on a regular basis and it is therefore highly recommended that you enable automatic updates. If an update is found the following Update Notifier window will pop up:...
  • Page 22 Done button to close the Update Notifier. If you choose not to “Enable automatic updates” you can still check for updates for your Tobii software and update them manually using the C-Series Update Notifier. To open and activate the C-Series Update Notifier manually (this opens...
  • Page 23: Shutting Down The Device

    Tobii C-Series User’s Manual • Navigate in Windows from your desktop to Start Menu > All Programs > Tobii > C-Series Update Notifier and click on the C-Series Update Notifier icon, 5.2 Shutting Down the Device The device should be shut down using one of the following ways: •...
  • Page 24: Configuring A Switch To Power On Or Off

    Tobii C-Series User’s Manual 5.3 Configuring a Switch to Power On or Off 5.3.1 Configuring a Switch to Power On To configure a connected Switch to power on the device: Open the C-Series Hardware Options > Switches. Select the Enable switch X to power on device check box. To disable, click to clear the Enable switch X to power on device check box.
  • Page 25: Safety Settings: C-Series Hardware Options

    Tobii C-Series User’s Manual 5.4 Safety Settings: C-Series Hardware Options Upon starting the device, the safety settings in C-Series Hardware Options will open as the default page automatically (other that during the first start up of the device, when the C-Series Welcome Guide setup wizard will open first).
  • Page 26: Temperature Control Safety

    Tobii C-Series User’s Manual 5.4.2 Temperature Control Safety Before you can set the device usage in C-Series Hardware Options > Temperature Control you need to confirm the Temperature control safety details. To confirm: Open the C-Series Hardware Options > Safety Click on the Temperature control safety details text.
  • Page 27: Saving Changes For Future Sessions

    Tobii C-Series User’s Manual 5.4.3 Saving Changes for Future Sessions To save your changes for future sessions: Select the Save my changes for future sessions check box. Click Apply or OK to save. Both the audio and the temperature control settings will be stored in memory. If this check box is not selected when you click Apply or OK the settings will only be stored until you log out.
  • Page 28: Adapting The Touch Screen For The User

    Tobii C-Series User’s Manual 5.5 Adapting the Touch Screen for the User The Touch Screen interprets your touch and moves the cursor to wherever your finger contacts the screen. The Touch Screen can be “calibrated” for your touch, either by the separate touch screen software, TouchKit (Windows Vista), eGalaxTouch (Windows 7), or in the C-Series Hardware Options.
  • Page 29 Tobii C-Series User’s Manual Using the Touch Screen software calibration: For Windows Vista: Go to Start menu > All Programs > TouchKit > Configure Utility. For Windows 7: Go to Start menu > All Programs > eGalaxTouch> Configure Utility. Select the Tools tab.
  • Page 30: Adjusting The Backlight

    Tobii C-Series User’s Manual 5.6 Adjusting the Backlight You can adjust the display brightness level by: Opening the C-Series Hardware Options > Backlight. Moving the slider to the right to increase the brightness and to the left to decrease it. The backlight needs a short while to adjust when changing the brightness.
  • Page 31: Adjusting The Sound

    Tobii C-Series User’s Manual 5.6.1 Adjusting the Sound You can configure the built-in speakers using the Windows 7 Control Panel > Hardware and Sound and the C-Series Hardware Options. Refer to Microsoft’s information on how to configure the sound in the Windows 7 Control Panel.
  • Page 32: Using Headphones

    Tobii C-Series User’s Manual 5.7 Using Headphones If you want to enable the use of headphones: Open the C-Series Hardware Options > Audio. Select the Enable headphones check box. If you want to disable the use of headphones: Open the C-Series Hardware Options > Audio.
  • Page 33: Connecting To A Bluetooth® Device

    The built-in WLAN (Wireless Local Area Network) support enables connection to a wireless network in compliance with the standard 802.11 b/g for the C8 and C12 and 802.11 b/g/n for the C15. 5.9.1 Handling Licenses To be able to use WLAN communication, a license is required. To view or enter a license, go to the Licenses section in the C-Series Hardware Options.
  • Page 34: Connecting To A Wlan

    Using an antivirus program is strongly recommended. 5.10 Using the Camera The built-in camera allows you to take snapshots of items in front of the C-Series device. On the Tobii C8, the camera is located on the top of the device. Chapter 5...
  • Page 35: Using The Mobile Phone (Optional)

    Tobii C-Series User’s Manual On the Tobii C12 and Tobii C15, it is located on the back of the device. Refer to Tobii Communicator or alternative communication software manuals for camera function utilization. 5.11 Using the Mobile Phone (optional) Not applicable for RF Free units.
  • Page 36: Handling Licenses

    The Tira is a programmable infrared device that can be used to control equipment with IR remote controllers such as TV-sets or DVDs. Refer to Tobii Communicator or alternative communication software manuals on how to connect, configure and use IR remote controls.
  • Page 37: Handling Licenses

    Tobii C-Series User’s Manual Tira-2.1 (IR Environmental Control) If the device you are trying to control is not responding, try tilting the C-Series device up or down slightly to change angle at which the IR signal is being sent. 5.12.1 Handling Licenses To use the Tira, a license is required.
  • Page 38: Creating Shortcuts To Actions

    Tobii C-Series User’s Manual • Select the Tira check box. To disable Tira: • Clear the Tira check box. 5.13 Creating Shortcuts to Actions You can create shortcuts to tasks, called actions, by programming the quick access buttons and connected Switches. The quick access buttons are located on the right side of the C-Series device, named A, B and C.
  • Page 39: Selecting Actions

    Tobii C-Series User’s Manual Select Buttons or Switches, depending on which one you want to customize. Click Set action to view the dialog box where you can select the action you would like the button to perform. By selecting one of the actions, the options for this action will be revealed below the chosen action.
  • Page 40 Tobii C-Series User’s Manual The next time you click the Start Program option a list of previously selected programs will be displayed. You can then directly select a program from the list or click Browse if you want to start a program not in the list.
  • Page 41 Tobii C-Series User’s Manual To enable this option you have to install the Tobii Eye Control Suite and a CEye. See Tobii CEye Module chapter. Wireless – you can either set all radio connections on/off or each individual wireless unit on/off one by one, by clicking the options.
  • Page 42: Handling Licenses

    Tobii C-Series User’s Manual 5.14 Handling Licenses To add new and/or view existing licenses: • Open the C-Series Hardware Options > Licenses. add a license: Click Add License(s). In the Enter license box, type the new license and then click Add.
  • Page 43: System Information

    In the case of fatal damage to the C-Series device, Tobii Technology can remove the SD card and have it inserted into a new device for quick and easy retrieval and restoration of personal data and settings.
  • Page 44: Restoring The Factory Settings Of A C-Series Device

    Any licenses originally ordered together with the device will automatically be activated. Also, if the device was ordered without a CEye module, Tobii Eye Control Suite will have to be reinstalled if the device is intended to be used with a CEye.
  • Page 45: Tobii Ceye Module & Eye Control

    Eye Control The Tobii CEye Module is an eye control unit which is designed to dock seamlessly into a Tobii C12 or C15 (not used with C8) and operate with precision regardless of glasses, contact lenses, eye color or light conditions.
  • Page 46: Required Software

    Tobii C-Series User’s Manual 6.1.2 Required Software The required software for the CEye module is the Tobii Eye Control Suite. The Tobii Eye Control Suite includes two components: the interaction server application and a system tray application, Tobii Eye Control Options.
  • Page 47: Installation Of Eye Control Software From Usb Stick

    Be aware that after double-clicking the -Startup icon it may take up to a minute or so before the Tobii Eye Control Suite window will open. Though nothing appears to be happening during this time, drivers are being automatically installed.
  • Page 48: Using The Tobii Ceye Module

    6.2 Using the Tobii CEye Module 6.2.1 Positioning The Tobii C12 or C15 with the CEye attached is designed to work optimally when it is parallel to the user’s eyes at a distance of about 60 cm (23.5 in). This means that for those users leaning sideways or those lying down the C12/CEye or C15/CEye also needs to be tilted in order to keep the users eyes parallel to the screen and at the optimal distance.
  • Page 49: Track Box

    Tobii C-Series User’s Manual For information about calibration of the CEye see Using the Tobii C-Eye Module>Calibrating. Also check the lighting conditions, related to what is mentioned above, when calibrating. 6.2.3 Track Box The Tobii CEye allows for extensive head movement. Once the C12/ CEye or C15/CEye is properly calibrated and placed in front of the user, no further adjustments are required.
  • Page 50: Accessing The Tobii Eye Control Options

    Tobii Eye Control Options icon, , in the Notification area and then click Settings. In the list to the left in Tobii Eye Control Options, select which option you want to change. In the list to the right, the available options will be revealed.
  • Page 51: Creating A New Profile

    To create a new profile: Open Tobii Eye Control Options, click User Profiles. Enter a new name in the Profile name field. Select an existing profile in the Based on profile drop down list.
  • Page 52: Deleting A Profile

    Tobii C-Series User’s Manual 6.2.7 Deleting a Profile To delete a profile: Open Tobii Eye Control Options > User Profiles. Select a profile in the Profile to delete drop down list. Click Delete to delete the selected profile. The profile is deleted directly upon clicking Delete.
  • Page 53 Select Simulate activation if you want to see how the activation method will appear on the screen. The example is shown above the Simulate activation button. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 54: Showing Track Status

    Open the track status viewer in one of the following ways: Open Tobii Eye Control Options > Eye Tracking and select • the Track status button.
  • Page 55: Calibration

    6.3.1 Starting Calibration The calibration can be started in one of the following ways: • Open Tobii Eye Control Options > Eye Tracking and then click the Start Calibration... button. • Right-click (hold finger on icon for touch screen right clicking) on...
  • Page 56: Improving Calibration Point(S)

    OK or Apply and begin using eye control. It is the accuracy and functionality of the eye control that is affected by the quality of the calibration results. Try for the best calibration possible. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 57: Removing Calibration Point(S)

    .You can choose the points to be improved and calibrate only those points again. Improve one or more calibration points by: Opening Tobii Eye Control Options > Eye Tracking. Under Calibration Result marking the point(s) you want to improve.
  • Page 58: Customizing The Calibration

    Tobii C-Series User’s Manual 6.3.6 Customizing the Calibration To customize the calibration, follow the steps below. Open Tobii Eye Control Options > Calibration Settings. General Select calibration background by clicking the background color button and select the desired color. Specify the number of points you want to calibrate with (two, five or nine) from the Calibration points drop down list.
  • Page 59 Check the Animate stimuli check box if you want the stimuli to be animated. If you want to control the calibration, i.e. decide when to move the calibration stimuli, with a keyboard, check the Keyboard step- through check box. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 60: Customizing The Calibration Area

    To customize the calibration area, follow the steps below: Open Tobii Eye Control Options > Eye Tracking. Click the Calibration Area… button. A blue semi-transparent area is displayed on the desktop. You can move and resize the blue area to make it fit your preferred calibration area.
  • Page 61: Windows Control

    Settings. • Check the Auto start windows control at boot check box if you want Windows Control to auto start when the Tobii Eye Control Suite starts. 6.4.2 Windows Control Type Windows Control can be used in two different modes: •...
  • Page 62: Gaze Selection

    Tobii C-Series User’s Manual To select which type of WIndows Control you wish to use and to customize Windows Control: • Open Tobii Eye Control Options > Windows Control Settings. • Select your prefered type of Windows Control under Windows Control Type 6.4.3 Gaze Selection...
  • Page 63 Track Status Place Cursor Place Cursor Scroll Scroll Left Click Left Click Double Click Double Click Right Click Right Click Drag & Drop Drag & Drop Settings Settings Normal Selected High Precision Chapter 6 Tobii CEye Module & Eye Control...
  • Page 64 Taskbar (or outside of the screen) to end scrolling Left Click Task that performs a single left-click Double Click Task that performs a double left-click Right Click Task that performs a single right-click Chapter 6 Tobii CEye Module & Eye Control...
  • Page 65 (or icon on the screen) where you want to execute the Task. An automatic zoom function is enabled, ending in the selection of the icon or execution of the task. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 66 Selection • Gaze - Choose Gaze to use your gaze position to activate the zooming function that ends with the execution of the desired Task. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 67 Task in the Gaze Selection Toolbar. If you are using Gaze Selection with switch the Task Buttons will be “sticky”, if you need to deselect a Task just look back at the selected Task for a short moment. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 68: Mouse Emulation

    6.4.4 Mouse Emulation The Mouse Emulation mode makes it possible for the user to emulate and control a standard PC mouse pointer on the screen. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 69 Check this check box if you want Windows Control Mouse Emulation mode to automatically switch the desired mouse click selection back to a left click, , after a right click, , has been chosen and performed. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 70 (double right click) = cursor types (drag) and (drop) = cursor type (no movement) • Check the Custom cursors check box to activate custom cursors for Windows Control in Mouse Emulation mode. Chapter 6 Tobii CEye Module & Eye Control...
  • Page 71 If you want to perform a click with the magnifier: Select the magnifier. Select the other options as usual. The options will now have changed to reflect the magnification state. Right Click Zoom Left Click Zoom Chapter 6 Tobii CEye Module & Eye Control...
  • Page 72 When Windows Control is not enabled, pausing eye control can also be accomplished by looking at (about) the Tobii logo at the bottom/center of the Tobii CEye, then selecting, using eye control, the pause icon that pops Chapter 6 Tobii CEye Module & Eye Control...
  • Page 73 When scroll mode is activated you will see a shaded gradient over the window which will be scrolled. To scroll, look at the top or bottom of this gradient area. Scroll functionality can be turned off in Tobii Eye Control Options > Windows Control Settings > Turn off scroll functionality. Chapter 7...
  • Page 74: Product Care

    Product Care 7.1 Temperature & Humidity 7.1.1 General Use The Tobii C-series and CEye is best kept in dry conditions at room temperature. The recommended range for temperature and the humidity value for the device is as follows: Portable mode: •...
  • Page 75: Cleaning

    Tobii C-Series User’s Manual two protruding plastic tabs away from you with your thumbs. With some pressure the tabs should release and the side cover should come off. To reapply the side covers: Place the C-Series device face down on a flat surface with the side cover you wish to apply facing away from you.
  • Page 76: Cleaning Of The Speaker Mesh

    Tobii C-Series User’s Manual 7.3.1 Cleaning of the Speaker Mesh Spray the speaker mesh carefully with a water and dish soap mixture using a misting spray bottle. Wipe the mesh clean. If excess moisture gets into the speaker housing, make sure that it drains through the drainage holes (see illustration) in the back of the device.
  • Page 77: Transporting The C-Series Device

    Tobii C-Series User’s Manual 7.5 Transporting the C-Series Device Disconnect all the cables and either hold the device with both hands while carrying it, or use the included carrying strap/shoulder strap (the carrying strap/shoulder strap is not included for the C15).
  • Page 78: Appendices

    Tobii C-Series User’s Manual Appendices 8.1 Appendix A: Training Resources Tobii offers a range of training resources for the C-Series products and related communication products. You can find them on the Tobii website, www.tobii.com, including Getting Started Guides, webinars and Quick guides.
  • Page 79: Radio Wave Exposure And Specific Absorption Rate (Sar)

    This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The highest SAR value for the C8 device is: 1.025 W/kg. The highest SAR value for the C12 device is 0.107 W/kg. The highest SAR value for the C15 device is 0.16 W/kg.
  • Page 80 Tobii C-Series User’s Manual Guidance and manufacturer’s declaration – electromagnetic emissions The C-Series is intended for use in the electromagnetic environment specified below. The customer or the user of the C-Series device should assure that it is used in such an environment.
  • Page 81 Tobii C-Series User’s Manual Guidance and manufacturer’s declaration – electromagnetic immunity The C-Series device is intended for use in the electromagnetic environment specified below. The customer or the user of the C-series device should assure that it is used in such an environment.
  • Page 82 Tobii C-Series User’s Manual Guidance and manufacturer’s declaration – electromagnetic immunity The C-Series device is intended for use in the electromagnetic environment specified below. The customer of the user of the C-Series device should assure that it is used in such an environment.
  • Page 83 Tobii C-Series User’s Manual Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
  • Page 84: Industry Canada Statement

    (SAR) dans le CNR-102 à le grand public (environnement non contrôlé) des limites (1.6W/Kg). La valeur maximale mesurée est de SAR pour le C8 dispositif est: 1.025 W/kg. La valeur maximale mesurée est de SAR pour le C12 dispositif est: 0.107 W/kg. La valeur maximale mesurée...
  • Page 85 Tobii C-Series User’s Manual est de SAR pour le C15 dispositif est: 0.16 W/kg. Ce dispositif peut être exploité en toute sécurité avec un 0cm distance minimale entre le matériel et les corps de l’utilisateur. This Class B digital apparatus complies with Canadian ICES-003.
  • Page 86: Appendix D: Technical Specifications

    Tobii C-Series User’s Manual 8.4 Appendix D: Technical Specifications Tobii C8 Tobii C12 Tobii C15 Standard Model T-C84-R1.0A-V0 T-C12-R1.0A-V1 T-C15-R1.0A-V0 8.4” resistive touch, 12.1” resistive touch, 15.0” resistive touch, Screen CCFL backlit CCFL backlit LED backlit Screen resolution 800 x 600 pixels...
  • Page 87 Tobii C-Series User’s Manual Tobii C8 Tobii C12 Tobii C15 RF Free Model Tobii C8 RF Free Tobii C12 RF Free Tobii C15 RF Free 8.4” resistive touch, 12.1” resistive touch, 15.0” resistive touch, Screen CCFL backlit CCFL backlit LED backlit...
  • Page 88: Appendix E: Approved Accessories

    Variable, up to 40 Hz Accuracy gaze estimation 0,8 degrees 12.3 oz Weight 350 g 8.5 Appendix E: Approved Accessories For information about the latest approved Tobii Accessories, please visit the www.tobii.com website or contact your local Tobii reseller. Chapter 8 Appendices...
  • Page 90 (US Eastern Starndard Time, GMT -6) (Japan Standard Time, GMT +9) EUROPE, MIDDLE EAST, CENTRAL EUROPE NORWAY ASIA NORTH AMERICA AFRICA Tobii Technology GmbH Tobii Norge Tobii Technology, Ltd. Tobii ATI Tobii Technology AB Niedenau 45 Thormøhlens gate 55 3-4-13 Takanawa, Minato-ku 333 Elm Street Karlsrovägen 2D...