Seyeon FlexWatcher FW2170 User Manual

Flexwatcher fw2170

Advertisement

Quick Links

FW2170 User's Manual
Class A Digital Device (industrial & commercial environment)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to CE
and FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
M4067-00
FW2170 User's Manual
(Product Guide)
Version 4.16(Rev.E)
Sep. 27, 2012
1
Seyeon Tech Co., Ltd

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FlexWatcher FW2170 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seyeon FlexWatcher FW2170

  • Page 1 Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. M4067-00 Seyeon Tech Co., Ltd...
  • Page 2 Revised: September 27, 2012 About This Document This document is prepared for users of FW2170 supplied by Seyeon Tech Co., Ltd. It is assumed that the users are familiar with Microsoft Windows operating systems and Web browsers such as Internet Explorer.
  • Page 3: Table Of Contents

    FW2170 INSTALLATION AND BASIC SETUP ................15 3.1..............................15 EFORE NSTALLATION 3.2............................15 ACTORY EFAULT ETTINGS 3.3. FW2170 ..............................15 NSTALLING ............................15 3.4. ETWORK ONFIGURATION ADMIN MENU ............................ 17 4.1.............................17 NTERING DMIN 4.2............................18 DMIN TRUCTURE M4067-00 Seyeon Tech Co., Ltd...
  • Page 4 8.2.1. Transparent Mode ..............................27 UTILITIES ............................. 28 9.1...................................28 EBOOT 9.2................................28 ACTORY EFAULT 9.3................................29 YSTEM PDATE 9.3.1. All (Kernel, RAM disk, System, Web) Update ..................30 9.3.2. System and Web Update ..........................32 9.3.3. Web Only Update ..............................32 M4067-00 Seyeon Tech Co., Ltd...
  • Page 5: Product Overview

    Thus, if you install cameras in remote site, you can watch the remote site using video server and FlexWATCH® 2170 even though it might be located in a different city. Picture 1 : FW2170 M4067-00 Seyeon Tech Co., Ltd...
  • Page 6: Key Features

     Advanced alarm notification and service When sensor or motion is triggered at FlexWATCH™ 2170 Network media decoder invokes the 4ch Rotation view immediately and displays the alarm status.  Factory Default Button for system initialization. M4067-00 Seyeon Tech Co., Ltd...
  • Page 7: Preliminary Specification

    DC 12V/1A [SMPS], max power consumption ( DC12V, 600mA ) Certification FCC / CE / KCC Dimension(WXDXH) / 148(W)X118(D)X25(H) mm / about 0.25 Kg Weight * All specifications are subject to change without prior notice. Table 1 : Specification for FW2170 M4067-00 Seyeon Tech Co., Ltd...
  • Page 8: Fw2170 Packing List

    CD (User’s Manual, installation wizard and 1 ea Pictures) Table 2 : FW2170 Packing List Note: Please check all the listed items are included in your package. For any missing items, please contact your local distributor. M4067-00 Seyeon Tech Co., Ltd...
  • Page 9: Network Diagram

    FW2170 is able to decode Video stream Over IP network by IP Address and domain name, and AOIP Service. Once FW2170 is assigned Dynamic IP Address, it is possible to decode Video stream from Wide Area Network. M4067-00 Seyeon Tech Co., Ltd...
  • Page 10: Fw2170 With The Existing Analog System

    FW2170 User’s Manual 1.5.3. FW-2170 with the existing Analog System FW2170 decode and transmits Video stream to analog system so that it an can be applied with Video Matrix. M4067-00 Seyeon Tech Co., Ltd...
  • Page 11: Application

     Chain store, and Franchised restaurant monitoring  Remote branch office monitoring  Plant, Oil refinery, Power station monitoring  Globally presented branch office monitoring  Parking Lots, Gas Station monitoring M4067-00 Seyeon Tech Co., Ltd...
  • Page 12: Hardware Description

    This button changes Display Mode. As you press the button, the Display Mode will be Display Mode changed one by one from Channel 1 to Channel 4. If you press the button for 2 sec., you Switch can apply Rotation Mode directly. Table 3 : FW2170 Front View M4067-00 Seyeon Tech Co., Ltd...
  • Page 13: Rear View

    Component Port V-OUT Composite Port (Video Output Port) Audio Input Port Audio Output Port HDMI HDMI Port LAN Connector (10/100BaseT Ethernet auto sensing) Power (DC 12V/1A [SMPS]) POWER ON/OFF Table 4 : FW2170 Rear View M4067-00 Seyeon Tech Co., Ltd...
  • Page 14: Ctl Port Description

    Jack information for Mono Speaker or Video Out Jack. 1 : GND 2 : SPK 3 : V-OUT Picture 5 : V-out Jack 2.2.3. MIC Jack Description Jack information for MIC 1 : GND 2 : NC Picture 6 : MIC Jack M4067-00 Seyeon Tech Co., Ltd...
  • Page 15: Fw2170 Installation And Basic Setup

    Camera Configuration: Refer to “FlexWATCH™ Admin Menu User’s Manual”  Service Configuration: Refer to “FlexWATCH™ Admin Menu User’s Manual” Network Configuration 1) Run Internet Explorer and input IP address of FW2170. You will see log in window as below. M4067-00 Seyeon Tech Co., Ltd...
  • Page 16 If you succeed in connecting to FW2170 Network Decoder System, “Display Output Device” menu will be shown on the right side immediately and whole menus on the left side. Because, you mainly need this menu “Display Output Device” while using FW2170. M4067-00 Seyeon Tech Co., Ltd...
  • Page 17: Admin Menu

    Now the Admin Menu will be displayed as shown below. This will guide you to the top level menu items, which are System, Network, Display, Device and Utilities. Clicking any of these top level menu items will display submenu items and brief descriptions. M4067-00 Seyeon Tech Co., Ltd...
  • Page 18: Admin Menu Structure

    Device Number Device Configuration Serial Ports Transparent Mode Reboot Utilities Factory Default System Update 5. System Configuration Menu When you click on “System Configuration” item on Admin Menu, the following sub menu will be displayed. M4067-00 Seyeon Tech Co., Ltd...
  • Page 19: Server Name Setup

    Because you have replaced the password with a new one, the existing network connection made with old password to FlexWATCH™ Server is lost now. You will have to reconnect to the FlexWATCH™ server using new password. M4067-00 Seyeon Tech Co., Ltd...
  • Page 20: Network Configuration

    6.1.1. Static IP Configuration Selecting Network Configuration under Network configuration will show variables. Below picture is for products without wireless LAN. For static IP, select static IP and input values for IP address, NetMask, Gateway, DNS1, DNS2 and M4067-00 Seyeon Tech Co., Ltd...
  • Page 21: Dhcp Client Configuration

    Client PC. HTTP Port is the network port that is used when a Client PC connects to the FlexWATCH™ Server’s Web page. It can be assigned between 80 and 65535 and the default value is 80. M4067-00 Seyeon Tech Co., Ltd...
  • Page 22: View Network Status

     When it is set to PPP Client on WAN-Modem menu, and the FlexWATCH™ server has been connected to the network with ISP or PPP server. To configure, click “Network Status Notify” on Network Configuration menu. The following window will be shown. M4067-00 Seyeon Tech Co., Ltd...
  • Page 23 Password for SMTP server Sender Email address of Sender 1st / 2nd / 3rd Recipient Email Addresses of the Recipients (up to 3 persons) User Defined Message Message to be included in the Notification email M4067-00 Seyeon Tech Co., Ltd...
  • Page 24: Display Configuration

    In this part, you can configure “Display Output”, “Video Output”, “OSD Service”, “Audio”, “Initial Channel” and “Channel Dwelling Time” by choosing options. In other words, you can choose one option for each of items as below M4067-00 Seyeon Tech Co., Ltd...
  • Page 25: Channel Configuration

     Camera Number: The number of the Camera connected to FW2170  Login ID: ID for connecting to Admin. of FW2170  Login Password: Password to login  Confirm Password: Affirmation of the Password you entered  Display Mode: The type of display M4067-00 Seyeon Tech Co., Ltd...
  • Page 26: Device Configuration

    There are two serial ports configurable in the system, COM and AUX. COM port is primarily used for console, and AUX is for PTZ control, but they both can be used for other purposes when necessary. M4067-00 Seyeon Tech Co., Ltd...
  • Page 27: Transparent Mode

     Peer IP: IP address of other FlexWATCH™ server  Network Port: Network port number of the server  Data Start Pattern: Data start pattern (Not used if unchecked)  Data Size: Data size in single transfer (Not used if unchecked) M4067-00 Seyeon Tech Co., Ltd...
  • Page 28: Utilities

    9.2. Factory Default Whenever it is required to restore the configuration of Camera setup to factory default condition, you can do it here. Network configuration is not affected by this action. M4067-00 Seyeon Tech Co., Ltd...
  • Page 29: System Update

     All (Firmware, RAM disk, System, Web) Update: Update all four system images.  System and Web Update: Only System and Web images are to be updated. M4067-00 Seyeon Tech Co., Ltd...
  • Page 30: All (Kernel, Ram Disk, System, Web) Update

     Web Only Update: Only Web image is to be updated. Up-to-date system files can be downloaded in Support page of Seyeon Tech’s homepages at http://www.flexwatch.com. After the update is done, it is required to reboot the server. 9.3.1. All (Kernel, RAM disk, System, Web) Update Click the “Start”...
  • Page 31 “Next” button. If you’re not sure about the system update, you can restore the Factory Default condition by clicking “Factory Default” button. M4067-00 Seyeon Tech Co., Ltd...
  • Page 32: System And Web Update

    Click “OK” button to proceed the update, otherwise click “Cancel”. The rest of the process is the same as in All Update part. After update is done, click “Reboot” to start the system over. M4067-00 Seyeon Tech Co., Ltd...

Table of Contents