Notice The information in this document is provided for reference only. ACCES does not assume any liability arising out of the application or use of the information or products described herein. This document may contain or reference inform ation a nd p rodu cts protected by copyrights or patents and does not convey any license under the patent rights of ACCES, nor the rights of others.
Page 3
Terms and Conditions If a unit is suspected of failure, contact ACCES' Custom er Service de partm ent. Be pre pared to give the unit model number, serial number, and a description of the failure symptom(s). W e may suggest som e sim ple tests to confirm the fa ilure.
Functional Description The W M-IIRO-8 is an intelligent 8-bit parallel digital I/O unit that comm unicates with ACCES’s W ireless Serial Modem via a 900 MH z wireles s co nne ction. T he W ireless Serial Modem con nec ts to a host com puter’s standard C OM port using an RS232 (or RS485) serial com m unication s protoc ol.
Chapter 2: Installation POWER W M-IIRO -8 Plug the provide d AC wall adapto r to any stand ard A C w all outlet. W IRELESS SERIAL MODEM Lap tops : Plug the provide d AC wall adapto r to any stand ard A C w all outlet. Desktops: Ins tall th e provided two sectio n pow er cable.
Chapter 3: Option Selection FILTER RESPONSE SWITCH Jumpers are used to select input filtering on a channel-by-channel basis. W hen jumper FLT0 is installed, additional filtering is introduced for input bit 0, FLT1 for bit 1, etc. This additional filtering must be used whe n AC inputs are a pplied.
Connections The signal assignment to each of the screw terminal board’s pins are as follows: ‘Isolated Input’ Signal ‘Relay Outp ut’ Signal Terminal Block PCB Terminal Block PCB Relay 7 - normally closed Relay 7 - comm on +PWR* Relay 7 - normally open +PWR* Relay 6 - normally closed Relay 6 - comm on...
Page 10
+PW R*: Power is power from a local power supply. The voltage can be anywhere from 7.5 VDC to 16 VDC. Higher local power, 24 VDC for example, can be used if an external zener diode is used to reduce the voltage applied to RIOD24. (See Temperature de-rating com m ents in the Specification sectio n of this manual under "Power Re quired".) Man ual W M-IIRO -8...
Chapter 4: Software General You received ASII-based software on CD for use with W M-IIRO-8. ASCII programm ing permits you to write app lications in any high level language that supp orts A SC II string fu nction s. The comm unication protocol has two forms: addressed and non-addressed. Non-addressed protocol can be used when only one W M-IIRO-8 is in use.
Command List Re ad a ll 8 digital bits. xxCR Read a single digital bit. (00<=xx<=0 7) Oxx0xx Ou tput all 8 digital bits. Ox± Output either high or low on bit x Oxx± Output either high or low on bit xx Ox±xx Output either high or low on bit x for time xx Oxx±xx...
Command Functions The following paragraphs give details of the command functions, describe what the comm ands cause, and give examples. Please note that all comm ands have an acknowledgment response. You m ust w ait for a resp ons e from a com m and befo re an othe r com m and is sen t. Read Digital Inputs Re ad 8 bits Read bit number xx...
Page 14
W rite zeros to every od d bit SEND: RECEIVE: [CR] Read Change-of-state Re ad C OS bit. The pod can set a change-of-s tate flag for any input th at has been configured to do so. This comm and will read then reset that bit. Therefore, this comm and will always return "N[CR]" unless the T c om m and has first been u sed to enable cha nge -of-s tate detec t for an y given b it.
Page 15
Read Digital Input Counter Read digital input counter xx Tthis comm and will read how m any tim es b it xx ha s ch ang ed to its active state (as c onfigured with dx± or dx x±) since the last res et com m and (rxx). Input counters are configured as 16-bit counters.
Page 16
Exam ple: Read the greeting message SEND: Hello? RECEIVE: =Pod 00, W M-IIRO-8 Rev B2 Firmware Ver:1.01 ACCES I/O Products, Inc.[cr] Programming Pod Address A=xx Program the currently selected pod to respond at address xx This com m and cha nge s the pod 's addres s to xx. If the new a ddre ss is 00, the pod will be plac ed into non-add ressed mod e.
Page 17
Read and Store Digital Input Data FASTDATA Read digital bits 0-7 as fas t as possible These comm ands read the respective byte of d igital input data and store it in SRAM at the fastest poss ible rate: 21 microseconds between samples. The comm ands will store as much data as the pod can hold: R A M size -1KB yte.
Error Codes The following error codes can be returned from the pod: Invalid channel number (too large, or n ot a num ber. All channel numbers m ust be between 00 and 17 , in hex. (0-24 decima l)) Im prop er Syntax. (Not enough para m eters is the usua l culprit) Channel number is invalid for this task (For example, if you try to output to a bit that is set as an input bit, this error code will occur) Parity error.
• Connectivity: A serial cable connec ts the host com puter’s CO M po rt with ACC ES’s W M-D P-232 m odem , which in turn communicates with the WM-IIRO-8 via a 900 MHz wireless connection. • Intelligence: Type 8051 microcontroller family provides capability of local control.
Page 20
Isolated Inputs • Num ber: Eight • Type: Non-polarized, optically isolated from each other and from the com puter. (CMOS compatible) • Logic Input Low: -0.5 V to 0.8 V • Logic Input High: +3.0 V to +33.0 V • Isolation: 60V channel-to-ground or channel-to-channel •...
Page 21
For example, at an ambient temperature of 25 °C., the voltage V can be up to 15.9V . At an ambient temperature of 100°F (37.8°C), the voltage V can be up to 14V. • Storage Tem perature Range: -20 °C. to +70 °C. •...
Page 22
Customer Comments If you experience any problems with this manual or just want to give us som e fe edback , please em ail us at: manuals@accesio.com. Please detail any errors you find and include your mailing address so that we can send you any manual updates. 10623 Roselle Street, San Diego CA 92121 Tel.