ASL series、AL series、QE series、QM series Electric Tankless Water Heater Installation and Owner's Manual ASL Series QE Series Overheating Power QM Series AL Series Installation instructions for the licensed electrician and plumber. Please read and understand these instructions thoroughly and completely prior installation and before use.
IMPORTANT SAFETY INFORMATION Risk of Electric Shock! All SIDFEN ELECTRIC TANKLESS WATER HEATERS MUST BE INSTALLED BY A LICENSED ELECTRICIAN AND PLUMBER IN ACCORDANCE WITH ALL NATIONAL, APPLICABLE STATE, PROVINCIAL, AND LOCAL ELECTRICAL AND PLUMBING CODES PRIOR TO THE INSTALLATION OF ANY SIDFEN ELECTRIC TANKLESS WATER HEATER.
DO NOT install under water pipes or air conditioning lines that might leak or condense moisture that could then drip onto the SIDFEN electric tankless water heater. ▶IMPORTANT:...
Fig9 3.Mounting the Water Heater All SIDFEN ELECTRIC TANKLESS WATER HEATERS MUST BE INSTALLED BY A LICENSED ELECTRICIAN AND PLUMBER IN ACCORDANCE WITH ALL NATIONAL, APPLICABLE STATE, PROVINCIAL, AND LOCAL ELECTRICAL AND PLUMBING CODES PRIOR TO THE INSTALLATION OF ANY SIDFEN ELECTRIC TANKLESS WATER HEATER.
Page 9
It must be mounted in an upright position with the inlet and outlet water connection at AL Series Ⅱ the bottom of the water heater. Never ASL Series Fig12 install the water heater sideways. inch(mm) 2.95(75) QM Series...
4.Water Connection All SIDFEN ELECTRIC TANKLESS WATER HEATERS MUST BE INSTALLED BY A LICENSED ELECTRICIAN AND PLUMBER IN ACCORDANCE WITH ALL NATIONAL, APPLICABLE STATE, PROVINCIAL, AND LOCAL ELECTRICAL AND PLUMBING CODES PRIOR TO THE INSTALLATION OF ANY SIDFEN ELECTRIC TANKLESS WATER HEATER.
(minimum 1 inch deep) be installed and connected to a suitable drain. 5.Electrical Connection All SIDFEN ELECTRIC TANKLESS WATER HEATERS MUST BE INSTALLED BY A LICENSED ELECTRICIAN AND PLUMBER IN ACCORDANCE WITH ALL NATIONAL, APPLICABLE STATE, PROVINCIAL, AND LOCAL ELECTRICAL AND PLUMBING CODES PRIOR TO THE INSTALLATION OF ANY SIDFEN ELECTRIC TANKLESS WATER HEATER.
Page 12
Technical data sheet 145/10 290/20 INSTALLATION: Step1 Using a suitable wire gauge that meets all applicable electrical codes for the size of breakers used, run two wires and a ground wire from the home's main breaker panel to the water heater. Note: For the model(A12SL,A12L,A10L,Q8E,Q8M,Q6M) you need to run a pair of wire and ground wires.
Step 3 DOUBLE CHECK the electrical connections to make sure they are correct and that all wire connections are tight and secure. Also confirm that the correct breaker size and wire gauge has been used and confirm that the water heater has been connected to a ground in accordance with applicable codes.
Page 14
▶RECOMMENDATION: ◆(A12SL,A12L,A10L):To adjust the temperature of your water heater set the selector knob on high or 6 during the winter months, low or 2 during the summer and medium or 4 during spring and fall. ◆(Q8E,Q8M):To adjust the temperature of your water heater set the selector knob on high or 4 during the winter months, low or 2 during the summer and medium or 3 during spring and fall.
Maintenance SIDFEN electric tankless water heaters are designed for long service life. The water heater itself does not require any regular maintenance. However, to ensure consistent water flow, it is recommended to periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head.
SIDFEN USA INC and its authorized dealers shall not be liable for any water damage arising directly or indirectly from any defect in the water heater component parts or from its use.
Page 17
♨ This warranty is void of the product is not installed in accordance with relevant electrical and plumbing codes and in accordance with the installation procedures specified by SIDFEN USA INC. ♨ This warranty does not include labor or shipping or replacement parts or replacement products unless specifically specified in this warranty.