CleanStation SRS-DT3 Manual

CleanStation SRS-DT3 Manual

Jet action cleaning

Advertisement

Important: Do not attempt to operate the CleanStation
instructions and safety rules contained in this manual. Failure to comply may result in personal injury.
• As a normal industry safety practice, be sure the machine has been plugged into a 115VAC ground fault interrupt outlet.
• Protective neoprene gloves, as well as protective eye goggles should be worn when cleaning parts in the CleanStation
nearby is helpful to wash off any solution that splashes on exposed skin or parts. During normal operation of the CleanStation, the tank and lid will
become hot (up to 150F). Care should be taken to avoid exposed skin touching these hot surfaces causing a burn.
• Use stainless steel or plastic tongs to insert and remove parts from the CleanStation
• Ambient lighting in the area where CleanStation
Artificial lighting that achieves an intensity of 200 to 300 Lux is usually sufficient.
• When the CleanStation
TM
is cleaning parts, it should NOT be left unattended.
• When operating the CleanStation
switch in case quick shutdown is necessary. All normal operations should be performed facing the front, with the exception of accessing the drain valve,
which is located on the back of the CleanStation
TM
• CleanStation
weights approximately 63lb empty and should NEVER be moved when liquid is present in the tank. Sections 9 and 10 of the
Operations guide detail how to properly drain and dispose of used chemical solution prior to moving the CleanStation
• CleanStation
TM
is designed for indoor use only, at room temperatures between 65F and 80F. CleanStation will not operate at a temperature at or below
40F.
• CleanStation
TM
is designed for cleaning with WaterWorks Soluble Concentrate (or other suitable substitute recommended by Stratasys, Inc. or PM
Technologies), to clean P400-ABS modeling and P400-SR support material. It is NOT designed for cleaning or heating food, cosmetic or medical
products, nor metal or other non-water soluble plastic parts. Do not use chemicals that are not pre-qualified by PM Technologies, this will result in
voiding the warranty.
• CleanStation
TM
should NOT be used in an explosive atmosphere. Normal internal sparking of the pump motor could ignite fumes.
• CleanStation
TM
has a working dimension inside the tank of 10 inch by 11 inch by 12-1/4" inch. Be careful not to insert too many parts (to be cleaned) so
as to overflow the level of the tank.

Rules for Safe Operation

TM
is setup and used needs to be sufficient for the contents of the CleanStation to be seen with ease.
TM
, facing the front provides an unobstructed view of the control panel display, as well as direct access to the power
TM
.
CleanStation Dimension SRS-DT3
TM
until you have read thoroughly and understand all
TM
tank. DO NOT use aluminum tongs.
TM
Jet action cleaning
TM
.
Having a source of fresh water
TM
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRS-DT3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CleanStation SRS-DT3

  • Page 1: Rules For Safe Operation

    Having a source of fresh water nearby is helpful to wash off any solution that splashes on exposed skin or parts. During normal operation of the CleanStation, the tank and lid will become hot (up to 150F). Care should be taken to avoid exposed skin touching these hot surfaces causing a burn.
  • Page 2: Technical Specifications

    CleanStation Dimension SRS-DT3 Jet action cleaning Technical Specifications • Outside machine dimensions: 19-1/4 inch height by 23-1/2 inch width by 21-1/2 inch depth • Inside tank dimensions: 10”d x 11”h x 12-1/4”w • Tank holds 6 gallons of water • Weight (empty): 63lb •...
  • Page 3: Installation

    Installation 1. Selecting a location Select a clean, dry, well-lighted area with a minimum clearance of six inches between the CleanStation and any adjacent walls. It is especially important to select a level surface, due to liquid levels in the tank.
  • Page 4: Operation

    CleanStation Dimension SRS-DT3 Jet action cleaning Operation Lit when heater is on Four Digit, LED Display: Lit when pump is on Pump and Heater enable indicator Lit when enabled. Not used Set key Timer Indicator Up and Down keys Colon blinks when...
  • Page 5 Operation 1. Necessary supplies to operate • Protective neoprene gloves, as well as protective eye goggles should be worn when cleaning parts at the CleanStation . Having a source of fresh water nearby is helpful to wash off any solution that splashes on exposed skin.
  • Page 6 Pressing will manually stop the cleaning cycle. IMPORTANT: To immediately power off the CleanStation (in case of emergency), turn the power switch off and unplug the power cord.
  • Page 7: Cleaning Parts

    CleanStation Dimension SRS-DT3 Jet action cleaning Operation (continued) 7. Cleaning parts IMPORTANT: Always wear neoprene safety gloves and eye protection while handling concentrate. Follow the instructions on the bottle of solution concentrate from Stratasys. Please review the MSDS provided by Stratasys.
  • Page 8 An alternative would be to drain the solution into a container big enough to handle the full capacity of CleanStation . At that point mix in 270 ml of malic acid and dispose.
  • Page 9: Maintenance

    If you notice a significant decrease in the circulation of water, there may be a buildup of material blocking circulation flow. (1) Unplug and drain the CleanStation per the Operating instruction step 10 (remember to wear safety protection).
  • Page 10 • The CleanStation pump and motor are factory sealed and do not require any lubrication or seal replacement. • When replacing fuses, always unplug power to the CleanStation and keep the power cord in view. Keeping the power cord in view will ensure the CleanStation is not inadvertently plugged back in by someone else.
  • Page 11: Troubleshooting

    CleanStation Dimension SRS-DT3 Jet action cleaning Troubleshooting If CleanStation does not run - no power to the display. • Verify the power switch is turned on, the system is plugged into a power source, and that power is available. • Verify adequate water level in the tank. If water level in the tank...
  • Page 12 CleanStation Dimension SRS-DT3 Jet action cleaning Troubleshooting (continued) Parts take an abnormally long time to clean • Check the temperature of the water. Optimal temperature is 150F. • Cleaning times are faster with fresh cleaning solution. Change the solution whenever the water gets too dark (coffee brown in color).
  • Page 13: Warranty Information

    Warranty Information PM Technologies warrants that the CleanStation™ part cleaning system will be free of defects in materials and workmanship for a period of one year from the date of shipment. If the product proves defective during the warranty period, PM Technologies, at its option, will: •...

Table of Contents

Save PDF