  • Page 1 Operating & Installation Manual Arley Wood & Multifuel Stoves Arley 5 Flat Multifuel Stove PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Rev 1 June 2004...
  • Page 2 3 year Warranty . Should you have any questions about our Arley Stoves that are not covered in this manual, please contact the Aarrow dealer in your...
  • Page 3: Table Of Contents

    Parts List 27-29 Fuel Types GUARANTEE Lighting The Fire 11-12 3 Year Guarantee Extended Burning Customer Registration Over Firing SERVICE RECORD Ash Removal Service Record Final Factory Check List SERVICING Cleaning & Annual Maintenance 13-14 Accessories Arley Wood & Multifuel Stoves...
  • Page 4 TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www.solidfuel.co.uk THE USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY ARADA LTD WILL INVALIDATE THE APPLIANCE GUARANTEE. Arley Wood & Multifuel Stoves...
  • Page 5: Introduction

    • Use gloves to provide additional grip. controlled by the air inlet mechanism. Aarrow Fires are also fitted with an "air wash" so called because it provides a curtain of high speed THE PRINCIPLE OF THE FIRE preheated air behind the glass to help keep it clean and to provide secondary air/over draught.
  • Page 6: Check List

    7. Operating tool 8. Rear liner 9. Side liners 10. Feet and fixings 11. Optional optional optional optional woodburning accessory accessory accessory tray 12. Multifuel optional optional optional riddling kit accessory accessory accessory 13. Instructions Arley Wood & Multifuel Stoves...
  • Page 7: Technical Data

    Flue Diameter 102 (4”) 127 (5”) 127 (5”) 64 Wood 62 Wood 63 Wood 74 Wood 75 Wood 56 Wood Weight Packed (Kg) 78 MF 59 MF 67 MF 68 MF 67 MF 79 MF Arley Wood & Multifuel Stoves...
  • Page 8: Operating Instructions

    OPERATING INSTRUCTIONS FIREBOX LININGS & THROAT PRIMARY AIR FOR ARLEY STOVES On the Arley, primary air enters the appliance PLATE through the controls on the bottom of the fire The Arley Wood and Multifuel stoves firebox have door(s). Moving the control knobs to the right will...
  • Page 9: Multi-Purpose Operating Tool

    (Fig.8) Re-place the door(s) carefully over the hinges and slot in place. Fig. 5 Removal of the Arley 5 door •Unscrew the two nuts, on the inside of the door securing the retaining clips.
  • Page 10: Door Adjustment

    DOOR ADJUSTMENT FITTING THE FEET Once the appliance has been under fire for a period The Arley wood and multifuel stoves must be fitted of time the fire door may appear to have moved out with the feet supplied. of alignment with relation to the door aperture. This is quite normal and due to the settling of the casing.
  • Page 11: Fuel Types

    Phurnacite, Phurnacite Plus, system is frozen. Centurion, Maxibrite, Extracite, Pureheat, Blazebrite, Taybrite, Sunbrite (Doubles/Singles), Anthracite (Large Nuts), and Welsh Dry Steam Coal (Large/Small Nuts). Arley Wood & Multifuel Stoves...
  • Page 12: Extended Burning

    Do not attempt to re-light the fire until the are non-toxic, but which certain persons may find cause of the fume emission has been identified and have an unpleasant or irritant effect. Ensure that corrected. the area is well ventilated during this time. Arley Wood & Multifuel Stoves...
  • Page 13: Over Firing

    Replace the ash pan and close the fire door. CLINKER The formation of clinker suggests that the unit is being over-fired. Any clinker forming on the grate should be removed when cold. Arley Wood & Multifuel Stoves...
  • Page 14: Servicing

    Aarrow dealer. With a wire brush clean inside OUTER FINISH the appliance paying particular attention to the...
  • Page 15: Accessories

    To turn your multifuel stove into a dedicated woodburner. As shown in Fig. 10a below Fig. 10a MULTIFUEL UPGRADE KIT Available for the wood burning range to enable you to burn solid fuel in your Arley wood stove. (See Fig 10b) Fig. 10b ADD IN BOILERS...
  • Page 16: Installation

    Care should be taken to make sure that the hinges are not damaged during installation. Arley Wood & Multifuel Stoves...
  • Page 17: Firebox Liner Panels

    •Replace the front fuel retainer bars or multifuel grate. Note: Neither the rear firebox liners nor the side Fig. 13 Inserting Throat Plate in to Arley 11 firebox liners are "handed", both faces are multifuel. suitable for direct contact with the fire.
  • Page 18: Assembling The Multifuel Grate

    MULTIFUEL GRATE GRATE BAR REPLACEMENT GRATE The grates in the Arley Multifuel units comprise a After extended use it may be necessary to replace series of reciprocating cast iron bars seated on a some of the grate bars. Periodic inspection of the pivoted "comb".
  • Page 19: Interchangeable Canopies

    INSTALLATION INTERCHANGEABLE CANOPIES The canopy versions for the Arley 7 & 11 range is a flat top stove to which a low or high canopy can be fitted after installation and are interchangeable. These are fitted as follows: •To fit the interchangeable canopy (Fig 10c): •Remove the front clamps.
  • Page 20: Flues & Chimneys

    Factory made insulated chimney complying with BS 4543: Part 2 (often called "Class 1 prefabricated metal chimney"). These types of chimney should be installed in accordance with the Building Regulations and BS 7566: Parts 1 to 4. Arley Wood & Multifuel Stoves...
  • Page 21 Engineer): telephone 0800 0924019 Bookshops also www.nace.org.uk viewed ODPM website www.safety.odpm.gov.uk/bregs/brads.htm NACS (National Association of Chimney Sweeps): telephone 01785 811732 Details on the relevant Building Regulations and www.chimneyworks.co.uk BS British Standards are given in the "General Arley Wood & Multifuel Stoves...
  • Page 22 INSTALLATION Arley Wood & Multifuel Stoves...
  • Page 23 WITH BUILDING REGULATIONS AND IEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES A is minimum clearance for non-insulated flue = 1.5 x D to a non-combustible surface/material 3 x D to combustible surface/material Arley Wood & Multifuel Stoves...
  • Page 24: Add In Boilers/Water Connections

    In many cases your supplier will be able to offer advice and assistance. Arley wood and multifuel stoves offer the option of a cantilever boiler or a slab boiler, which occupies Direct Systems the position of the rear firebox liner panels.
  • Page 25 What is the height and distance of the hot water tank above the stove? A checklist (Pre-lighting Checks) appears in the Operating Instructions, but in addition to this the installer should: Arley Wood & Multifuel Stoves...
  • Page 26: Final Installation Check List

    I/we the undersigned confirm that the above details are correct. In my opinion, these works comply with the relevant requirements in Part J of Schedule 1 to the Building regulations. Print name and title....................Profession................Capacity........................Telephone................Address................................Post code........Signed......................Date......... Registered membership of..(e.g. CORGI, OFTEC, HETAS, NACE, NACS)..........Arley Wood & Multifuel Stoves...
  • Page 27: Parts List

    4. Hot Plate AFGS064 AFGS064 AFS009 AFS009 AFS009 AFS009 5. Operating Tool AFS008 AFS008 AFS008 AFS008 AFS008 AFS008 6. Ashpan AFS050 AFS058 AFS058 AFS058 AFS058 AFS050 7. Flue Spigot AFS009A AFS009A AFS010 AFS010 AFS010 AFS010 Arley Wood & Multifuel Stoves...
  • Page 28 13. Hinge kit Comprises 2 Hinges & 4 AFS047 AFS047 AFS047 AFS047 AFS047 AFS047 Fixings Per Set. 14. Airwash AFS1144 AFS1144 AFS1144 AFS1144 AFS1144 AFS1144 (Curved) 15. Feet & Fixings AFS1153 AFS1153 AFS1153 AFS1168 AFS1153 AFS1168 Arley Wood & Multifuel Stoves...
  • Page 29: Parts List

    AFS1170 21. Aarrow Fires Gauntlet Gloves AFS997 AFS997 AFS997 AFS997 AFS997 AFS997 22. Wood Burning Tray ARL5 ARL7 ARL11 WBTRAY AFS1151 WBTRAY AFS1160 WBTRAY AFS1162 23. Multifuel Upgrade Kit ARL5M ARL7M ARL11M GRATE GRATE GRATE Arley Wood & Multifuel Stoves...
  • Page 30: Guarantee

    Aarrow fire. If you think your fire is not working correctly or in When you buy an Aarrow Fire, you are not only the case of a breakdown, please call your local buying a first class appliance - you are buying a...
  • Page 31: Service Record

    Work Carried Out Signature Date of Visit Should you have any questions about your Arley Wood or Multifuel Stove that is not covered in this manual please contact your Aarrow retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart.
  • Page 32: Final Factory Check List

    FINAL FACTORY CHECK LIST Model........Serial No......QUALITY FINISH I’ve checked it PARTS and it’s O.K. FLUE OUTLET HOT PLATE FUEL RETAINERS GRATE BARS / WOOD TRAY Assembled by......FIREBOX LININGS THROAT PLATE Checked by ........ AIR WASH DOOR CATCHES FEET &...

Table of Contents