UWEX 722 C Operation Manual

Underwater metal detector

Advertisement

Quick Links

®
UWEX
722 C
Underwater Metal Detector
Operations Manual

Advertisement

Table of Contents
loading

Summary of Contents for UWEX 722 C

  • Page 1 ® UWEX 722 C Underwater Metal Detector Operations Manual...
  • Page 2: Contact Information

    ® Operations Manual UWEX 722 C _________________________________________________________________________ Contact Information Copyright Ebinger Prüf- und Ortungstechnik GmbH © 2005, Ebinger Prüf- und Ortungstechnik Hansestr. 13 GmbH. 51149 Köln / Cologne Deutschland Unauthorized duplication and distribution Tel: +49-2203-97710-0 of this manual or parts of it violates...
  • Page 3 ® Operations Manual UWEX 722 C _________________________________________________________________________ READ INSTRUCTIONS IN CONJUNCTION WITH YOUR STANDARD OPERATING PROCEDURES (SOP’S) BEFORE DETECTOR USE READ THIS MANUAL CAREFULLY BEFORE ASSEMBLING OPERATING OR CARRYING OUT MAINTENANCE ON THE DEVICE EEP THIS BOOKLET IN A SAFE PLACE FOR...
  • Page 4 ® Operations Manual UWEX 722 C _________________________________________________________________________ ___________________________________________________________________ © 2005, Ebinger Prüf- und Ortungstechnik GmbH.
  • Page 5: Table Of Contents

    ® Operations Manual UWEX 722 C _________________________________________________________________________ Contents 1. General Safety information 2. General 3. Principle of operation 4. Main characteristics 5. Constructional features 6. Putting into operation 7. Testing before use 8. Detector use 9. Suppression of interference 10. Battery change 11.
  • Page 6: General Safety Information

    ® Operations Manual UWEX 722 C _________________________________________________________________________ 1. General Safety Information This chapter contains important safety information, which has to be observed when using the detector. About this manual Important! • Please read and observe the following instructions before prior to the use of the detector: •...
  • Page 7 ® Operations Manual UWEX 722 C _________________________________________________________________________ Product Safety Advice Technical failures WARNING – Do not use equipment with damaged cables or connection elements as you are risking short circuits, burns or electric shock! Replace faulty or missing components only by original EBINGER-spare parts to avoid short circuits, wrong polarity, electric shocks or overload.
  • Page 8 ® Operations Manual UWEX 722 C _________________________________________________________________________ Awareness whilst operating the product WARNING – Equipment, which is used in danger inclined activities, shall only be operated according to valid SOPs and by qualified personnel which has been successfully trained according to the relevant national and international standards and regulations.
  • Page 9 ® Operations Manual UWEX 722 C _________________________________________________________________________ Good Guidance German regulations and instructions on how to deal with unexploded ordnance found by accident may serve as guidance: • All munitions found shall not be touched, its position shall not be changed, the site shall be clearly marked and precautions taken to avoid intervention of the munitions by third parties.
  • Page 10 ® Operations Manual UWEX 722 C _________________________________________________________________________ ® Pic. UWEX 722 C with single sided headset ___________________________________________________________________ © 2005, Ebinger Prüf- und Ortungstechnik GmbH.
  • Page 11: General

    Principle of Operation ® The UWEX 722 C works on the Ebinger pulse induction method which can also be applied in conductive salt water. In such case the delay adjustment needs correction (see page 14) ___________________________________________________________________ © 2005, Ebinger Prüf- und Ortungstechnik GmbH.
  • Page 12 ® Operations Manual UWEX 722 C _________________________________________________________________________ Short magnetic pulses, emitted by the search coil generate an electromagnetic field around the search head which induces eddy currents into conductive objects (i.e. metal) being within the reach of the detector. Fig.
  • Page 13: Main Characteristics

    ® Operations Manual UWEX 722 C _________________________________________________________________________ The main advantage of the pulse induction method consists in the possibility to exclude the reading of interference with short responses signals by a delayed activation of the receiver. Interference from conductive soil, salt water or small metal scrap, i.e. nails or wires, can be strongly reduced by a decoupling in time.
  • Page 14: Constructional Features

    ® The UWEX 722 C is a battery operated, pressure waterproof metal detector for underwater and normal land use. It consists of a search head with joint, which is flanged to the detector handle containing the detector electronics and the battery compartment.
  • Page 15: Putting Into Operation

    ® Operations Manual UWEX 722 C _________________________________________________________________________ Putting into operation For standard underwater use the detector may be used in its short version. For normal land use or when working in underwater vegetation the extension rod can be fitted to the threaded end of the detector handle if the slope is inserted into the extension rod.
  • Page 16: Testing Before Use

    Testing before use ® Take UWEX 722 C out from its carrying bag. Unscrew handle. Insert 9V battery watching correct polarity as indicated by markings. Refit handle. To extend detector use extension rod. Rotate handle clockwise into ON position with white dots matching and set sensitivity knob to required sensitivity level.
  • Page 17: Detector Use

    ® Operations Manual UWEX 722 C _________________________________________________________________________ Pic. coarse adjuster for sensitivity inside battery compartment Using the detector To inspect an area carry search head in scanning movement flat and parallel over ground. Make sure that searched strips overlap and avoid dead spots. The detector operates on a static mode showing metal objects by an audio alarm as long as the search head is held over a detected object.
  • Page 18: Suppression Of Interference

    ® Operations Manual UWEX 722 C _________________________________________________________________________ For pinpoint location of shallow buried metal the search coil may be used vertically over the signal area. From experience the detection signals can be interpreted in the right way. A small metal object buried next to the surface will cause a short but intense signal.
  • Page 19 ® Operations Manual UWEX 722 C _________________________________________________________________________ Pic. Delay adjuster version until serial no 436 Turn upper trimmer marked 'Z' (approx. 3 - 4 turns) in clockwise direction to increase the delay, which reduces interference signals from saltwater and scrap metal.
  • Page 20: Battery Change

    ® Operations Manual UWEX 722 C _________________________________________________________________________ FIG. 6: Delay switch inside detector handle 10. Battery change If the device is not used for a long time it may occur that the two O-rings beneath the handle stick to the surface and the handle only comes off after jerky anticlockwise rotation.
  • Page 21: Maintenance

    ® Operations Manual UWEX 722 C _________________________________________________________________________ 11. Maintenance Pre – issue routine: Check equipment is tight, test battery power and detector functions. Routine after use: After use in salt-water wash detector externally with sweet water. Wipe with tissue and dry equipment with open battery compartment for approx.
  • Page 22: Technical Data

    ® Operations Manual UWEX 722 C _________________________________________________________________________ 12. Technical Data − - Power supply. 1 x 9V E-Block (6LR61 or U9VL) - Service life Approx. 20 h (lithium 40 h) at +20° C − - Temperature range. -20°C to +55°C Dimensions.

Table of Contents